¡¾ÇóÖú¡¿ÇócifµÄBÀà´íÎó½â¾ö43
±¾ÈË×ö¸öÓлúµ¥¾§£¬µ«Checkʱ³öÏÖÁËBÀà´íÎó£¬Ôõô½â¾ö°¡¸ßÊÖÃÇ£¬°ï°ïÎÒ
Alert level B
CELLV02_ALERT_1_B The supplied cell volume s.u. differs from that
calculated from the cell parameter s.u.'s by > 4
Calculated cell volume su = 22.83
Cell volume su given = 16.00
PLAT415_ALERT_2_B Short Inter D-H..H-X H1A .. H16 .. 2.07 Ang.
ʲôÒâË¼ÄØÕâÁ½¸öÎÊÌâ¸ÃÔõô½â¾ö°¡£¿
[ Last edited by baiyuefei on 2011-2-19 at 15:54 ]
·µ»ØÐ¡Ä¾³æ²é¿´¸ü¶à
½ñÈÕÈÈÌû
¾©¹«Íø°²±¸ 11010802022153ºÅ
°Ñ16.00¸ÄΪ22.00»ò22.83 ¾Í¿ÉÒÔÁË
µÚÒ»¸ö´íÎóÄã¿ÉÒÔ¼ì²éÏÂÄãµÄinsÎļþÖÐÌîдµÄ·Ö×ÓʽºÍZÖµÊÇ·ñÕýÈ·
µÚ¶þ¸ö´íÎóÄãÊÔÒ»ÊÔ°ÑÇâɾµô£¬ÔÙÖØÐ¼ÓÇâ
¸ßÊÖ£¬°´ÄúµÄ·½·¨ÎÒ×öÁË£¬»¹ÊdzöÏÖ´íÎ󣬲»Äܽâ¾ö¡£
ÄúÄܲ»ÄܰïÎÒϰ¡£¿ÎÒ°ÑÎļþ´«¸øÄú£¬Äú°ïŪϰ¡£¿ÊµÔÚÊÇΪÄÑËÀÎÒÁË£¬²»ÖªÈçºÎÊǺ᣽ð±Ò²»ÊÇÎÊÌ⣬¶àÉÙ¶¼ÐУ¬ÎÒ¼ÓÄúQQºÃÂ𣿰ÑÎļþ·¢¸øÄú
Èç¹ûÊÇÕâÑù»°£¬¿ÉÄÜÊÇÎó²îµÄÎÊÌ⣬ÄãҪȷʵÏëÏû³ý£¬¿ÉÒÔÊÔÒ»Ê԰Ѿ§°ûÌå»ýºóÃæÀ¨ºÅÖеÄÊýÖµÐ޸ľͿÉÒÔÁË¡£
Èç
_cell_volume 500.1(17)
¸ÄΪ
_cell_volume 500.1(22)
×îºÃÖØÐÂÊռϾ§Ì壬»òÕßÖØÐ»¹ÔÊý¾ÝÒ²ÐíÆ«²î»áСµã£¬ÕâÑù¸ÄÓеã´Û¸ÄÊý¾ÝÖ®ÏÓÒÉ£¬ºÇºÇ
µÚÒ»ÎÊÌâÒѾ½â¾ö£¬µ«µÚ¶þ¸öÎÊÌâÈ·²»ÖªÈçºÎÊǺã¿È¥µôHÖØÐÂÀíÂÛ¼ÓH»¹ÊdzöÏÖÕâ¸ö´íÎó£¬Ôõô½â¾ö°¡£¬¸ßÊÖ°ï°ïÎÒ°
£¬
µÚ¶þ¸öÎÊÌâÒª¿´¾ßÌåÇé¿öÁË£¬ÇâÊDz»ÊÇOÉÏÃæµÄ£¿
ÊÇNÉϵÄH£¬Ëü¸øÎÒ¶à¼ÓÁ˸öH£¬ÀíÂÛ¼ÓHµÄʱºò¡£
£¿£¿£¿