±±¾©Ê¯ÓÍ»¯¹¤Ñ§Ôº2026ÄêÑо¿ÉúÕÐÉú½ÓÊÕµ÷¼Á¹«¸æ
²é¿´: 1066  |  »Ø¸´: 5
µ±Ç°Ö»ÏÔʾÂú×ãÖ¸¶¨Ìõ¼þµÄ»ØÌû£¬µã»÷ÕâÀï²é¿´±¾»°ÌâµÄËùÓлØÌû

³¾Ïãפ·ç

½ð³æ (СÓÐÃûÆø)

[½»Á÷] Ó©¹âËØÃ¸¼ì²âϵͳ ÒÑÓÐ2È˲ÎÓë

ÓÐûÓгæÓÑÓùýPromega¹«Ë¾µÄÓ©¹âËØÃ¸¼ì²âϵͳÊÔ¼ÁºÐ°¡£¿ÓõÄÊÇÄÄÖÖÐͺŵģ¿
»Ø¸´´ËÂ¥

» ²ÂÄãϲ»¶

» ±¾Ö÷ÌâÏà¹ØÉ̼ÒÍÆ¼ö: (ÎÒÒ²ÒªÔÚÕâÀïÍÆ¹ã)

» ±¾Ö÷ÌâÏà¹Ø¼ÛÖµÌùÍÆ¼ö£¬¶ÔÄúͬÑùÓаïÖú:

ÒÑÔÄ   »Ø¸´´ËÂ¥   ¹Ø×¢TA ¸øTA·¢ÏûÏ¢ ËÍTAºì»¨ TAµÄ»ØÌû

³¾Ïãפ·ç

½ð³æ (СÓÐÃûÆø)

ÒýÓûØÌû:
3Â¥: Originally posted by ÏĶûlist at 2014-07-21 18:48:20
Dual-luciferase Reporter assay system

ÕâÊÇË«»ùÒòµÄ°É£¿ÓÐûÓÐÓùýµ¥»ùÒòµÄѽ£¿
4Â¥2014-07-21 20:42:28
ÒÑÔÄ   »Ø¸´´ËÂ¥   ¹Ø×¢TA ¸øTA·¢ÏûÏ¢ ËÍTAºì»¨ TAµÄ»ØÌû
²é¿´È«²¿ 6 ¸ö»Ø´ð

ÏĶûlist

½ð³æ (ÖøÃûдÊÖ)

¡ï
Сľ³æ: ½ð±Ò+0.5, ¸ø¸öºì°ü£¬Ð»Ð»»ØÌû
Dual-luciferase Reporter assay system
3Â¥2014-07-21 18:48:20
ÒÑÔÄ   »Ø¸´´ËÂ¥   ¹Ø×¢TA ¸øTA·¢ÏûÏ¢ ËÍTAºì»¨ TAµÄ»ØÌû

³¾Ïãפ·ç

½ð³æ (СÓÐÃûÆø)

ÒýÓûØÌû:
3Â¥: Originally posted by ÏĶûlist at 2014-07-21 18:48:20
Dual-luciferase Reporter assay system

ÇëÎÊÄãÓÃÕâ¸ö¼ì²âµÄʱºòÊǶàÑùÆ·»¹ÊÇÉÙÑùÆ·£¬ÎÒ¿´Ëü˵Ã÷ÊéÉÏ˵µÄÊÇ·¢¹âÖÁÉÙ³ÖÐøÒ»·ÖÖÓ£¬ÄÇô»á²»»áµÈ¼ÓÍêÈ«²¿µÄʱºòÇ°Ãæ¼ÓµÄ¾Í¿ªÊ¼Ë¥ÍËÁËÄØ£¿

» ±¾ÌûÒÑ»ñµÃµÄºì»¨£¨×îÐÂ10¶ä£©

5Â¥2014-07-22 09:16:43
ÒÑÔÄ   »Ø¸´´ËÂ¥   ¹Ø×¢TA ¸øTA·¢ÏûÏ¢ ËÍTAºì»¨ TAµÄ»ØÌû

ssssllllnnnn

ÖÁ×ðľ³æ (ÖªÃû×÷¼Ò)

Translator and Proofreader


¡ï
Сľ³æ: ½ð±Ò+0.5, ¸ø¸öºì°ü£¬Ð»Ð»»ØÌû
Ëͺ컨һ¶ä
ÒýÓûØÌû:
5Â¥: Originally posted by ³¾Ïãפ·ç at 2014-07-21 20:16:43
ÇëÎÊÄãÓÃÕâ¸ö¼ì²âµÄʱºòÊǶàÑùÆ·»¹ÊÇÉÙÑùÆ·£¬ÎÒ¿´Ëü˵Ã÷ÊéÉÏ˵µÄÊÇ·¢¹âÖÁÉÙ³ÖÐøÒ»·ÖÖÓ£¬ÄÇô»á²»»áµÈ¼ÓÍêÈ«²¿µÄʱºòÇ°Ãæ¼ÓµÄ¾Í¿ªÊ¼Ë¥ÍËÁËÄØ£¿...

These kind of assays are usually done with a Luminescence Microplate Reader. All you need to do is to prepare your cell lysates and add them to a 96-well plate. Then the machine will read the plate for you. The machine reads well by well in the plate and will inject the Stop & Glo reagents right before reading....

You can do it manually if you can't fine the machine.  In this case, you have to add the reagents by yourself and read the samples right away. It's time-consuming though.

If you do such experiments as transient transfection and transactivation assays, you need cotransfect a control reporter (Renilla series). That's the reason that you need a dual-luciferase assay system.
6Â¥2014-07-22 11:47:10
ÒÑÔÄ   »Ø¸´´ËÂ¥   ¹Ø×¢TA ¸øTA·¢ÏûÏ¢ ËÍTAºì»¨ TAµÄ»ØÌû
×î¾ßÈËÆøÈÈÌûÍÆ¼ö [²é¿´È«²¿] ×÷Õß »Ø/¿´ ×îºó·¢±í
[¿¼ÑÐ] 315µ÷¼Á +4 0860Çóµ÷¼Á 2026-03-26 5/250 2026-03-27 11:23 by wangjy2002
[¿¼ÑÐ] ²ÄÁÏÇóµ÷¼Á +8 @taotao 2026-03-21 8/400 2026-03-27 11:21 by wangjy2002
[¿¼ÑÐ] 314Çóµ÷¼Á +3 ÏªÔÆçæ 2026-03-26 3/150 2026-03-27 11:20 by sanrepian
[¿¼ÑÐ] ²ÄÁÏÇóµ÷¼Á +5 .m.. 2026-03-25 5/250 2026-03-27 11:08 by ²»³Ôô~µÄ؈
[¿¼ÑÐ] 325Çóµ÷¼Á +3 Aoyijiang 2026-03-23 3/150 2026-03-26 20:46 by ²»³Ôô~µÄ؈
[¿¼ÑÐ] 281Çóµ÷¼Á +3 ÑÇ¿ËÎ÷good 2026-03-26 5/250 2026-03-26 19:48 by ²»³Ôô~µÄ؈
[¿¼ÑÐ] 334·Ö Ò»Ö¾Ô¸ÎäÀí ²ÄÁÏÇóµ÷¼Á +4 ÀîÀî²»·þÊä 2026-03-26 4/200 2026-03-26 16:00 by ²»³Ôô~µÄ؈
[¿¼ÑÐ] 309Çóµ÷¼Á +4 gajsj 2026-03-25 5/250 2026-03-26 00:27 by Dyhoer
[¿¼ÑÐ] ¿¼Ñе÷¼Á +6 À´ºÃÔËÀ´À´À´ 2026-03-21 7/350 2026-03-25 22:43 by 418490947
[¿¼ÑÐ] ²ÄÁÏÓ뻯¹¤328·Öµ÷¼Á +6 ¡££¬¡££¬¡££¬¡£i 2026-03-23 6/300 2026-03-25 22:30 by 418490947
[¿¼ÑÐ] ÍøÂç¿Õ¼ä°²È«0839Õе÷¼Á +4 w320357296 2026-03-25 6/300 2026-03-25 17:59 by 255671
[¿¼ÑÐ] ¡¾2026¿¼Ñе÷¼Á¡¿ÖÆÒ©¹¤³Ì 284·Ö ÇóÏà¹Ø×¨Òµµ÷¼ÁÃû¶î +4 Ô¬Û¼Û¼ 2026-03-25 8/400 2026-03-25 14:32 by lbsjt
[¿¼ÑÐ] ¸÷λÀÏʦÄúºÃ£º±¾È˳õÊÔ372·Ö +5 jjÓ¿77 2026-03-25 6/300 2026-03-25 14:15 by mapenggao
[¿¼ÑÐ] 0854µç×ÓÐÅÏ¢Çóµ÷¼Á +7 ¦Á____ 2026-03-22 9/450 2026-03-25 13:37 by ¦Á____
[¿¼ÑÐ] 347Çóµ÷¼Á +4 L when 2026-03-25 4/200 2026-03-25 13:37 by cocolv
[¿¼ÑÐ] 0703»¯Ñ§µ÷¼Á£¬Çóµ¼Ê¦ÊÕ +7 ÌìÌìºÃÔËÀ´Éϰ¶° 2026-03-24 7/350 2026-03-24 20:26 by peike
[¿¼ÑÐ] Ò»Ö¾Ô¸¹ú¿Æ¹ý³ÌËù081700£¬274Çóµ÷¼Á +3 ÈýË®ÑÐ0Ë®Á¢·½ 2026-03-23 3/150 2026-03-23 23:11 by MajorWen
[¿¼ÑÐ] 308Çóµ÷¼Á +3 īīĮ 2026-03-21 3/150 2026-03-22 16:54 by i_cooler
[¿¼ÑÐ] ÉúÎïѧµ÷¼Á +5 Surekei 2026-03-21 5/250 2026-03-22 14:39 by tcx007
[¿¼ÑÐ] Ò»Ö¾Ô¸±±¾©»¯¹¤´óѧ070300 ѧ˶336Çóµ÷¼Á +5 vvÃÔ 2026-03-21 8/400 2026-03-22 14:20 by ColorlessPI
ÐÅÏ¢Ìáʾ
ÇëÌî´¦ÀíÒâ¼û