| ²é¿´: 1066 | »Ø¸´: 5 | |||
| µ±Ç°Ö»ÏÔʾÂú×ãÖ¸¶¨Ìõ¼þµÄ»ØÌû£¬µã»÷ÕâÀï²é¿´±¾»°ÌâµÄËùÓлØÌû | |||
³¾Ïãפ·ç½ð³æ (СÓÐÃûÆø)
|
[½»Á÷]
Ó©¹âËØÃ¸¼ì²âϵͳ ÒÑÓÐ2È˲ÎÓë
|
||
| ÓÐûÓгæÓÑÓùýPromega¹«Ë¾µÄÓ©¹âËØÃ¸¼ì²âϵͳÊÔ¼ÁºÐ°¡£¿ÓõÄÊÇÄÄÖÖÐͺŵģ¿ |
» ²ÂÄãϲ»¶
0703»¯Ñ§Çóµ÷¼Á£¬¸÷λÀÏʦ¿´¿´ÎÒ£¡£¡£¡
ÒѾÓÐ3È˻ظ´
339Çóµ÷¼Á
ÒѾÓÐ5È˻ظ´
287Çóµ÷¼Á
ÒѾÓÐ8È˻ظ´
Ò»Ö¾Ô¸±±¾©»¯¹¤´óѧ 070300 ѧ˶ 336·Ö Çóµ÷¼Á
ÒѾÓÐ8È˻ظ´
085602 »¯¹¤×¨Ë¶ 338·Ö Çóµ÷¼Á
ÒѾÓÐ5È˻ظ´
0856£¬²ÄÁÏÓ뻯¹¤321·ÖÇóµ÷¼Á
ÒѾÓÐ4È˻ظ´
Ò»Ö¾Ô¸±±¾©»¯¹¤´óѧ²ÄÁÏÓ뻯¹¤ 264·Ö¸÷¿Æ¹ýAÇø¹ú¼ÒÏß
ÒѾÓÐ10È˻ظ´
266Çóµ÷¼Á
ÒѾÓÐ8È˻ظ´
265Çóµ÷¼Á
ÒѾÓÐ3È˻ظ´
286Çóµ÷¼Á
ÒѾÓÐ6È˻ظ´
» ±¾Ö÷ÌâÏà¹ØÉ̼ÒÍÆ¼ö: (ÎÒÒ²ÒªÔÚÕâÀïÍÆ¹ã)
» ±¾Ö÷ÌâÏà¹Ø¼ÛÖµÌùÍÆ¼ö£¬¶ÔÄúͬÑùÓаïÖú:
NF-kB¿¹ÌåÎÊÌ⣬ϣÍû´ó¼Ò°ï棡
ÒѾÓÐ3È˻ظ´
Ë«·Ö×ÓÓ«¹â¼¼Êõ
ÒѾÓÐ6È˻ظ´
ÓÐÈË×ö¹ýË«±¨¸æ»ùÒòµÄ¹ý±í´ïÖÊÁ£ÔØÌåô£¿
ÒѾÓÐ5È˻ظ´
Ó«¹âµ°°×Ժ˱í´ïÖÊÁ£
ÒѾÓÐ13È˻ظ´
˫ӫ¹âËØÃ¸ÔØÌå
ÒѾÓÐ4È˻ظ´
ËÇÓÃ´ó¶¹ÆÉΪʲôҪ½øÐÐÄòËØÃ¸»îÐԵļì²â£¿
ÒѾÓÐ4È˻ظ´
»ùÒò×éÉÏsnpλµã·Ö²¼µÄËæ»úÐÔÈçºÎ¼ìÑ飿
ÒѾÓÐ3È˻ظ´
ÊÀ½çÖøÃûµÄÉúÎï¼¼Êõ¹«Ë¾
ÒѾÓÐ32È˻ظ´
ÓйØÎÈתNF-kBÓ©¹âËØÃ¸±¨¸æ»ùÒòµÄÎÊÌâ
ÒѾÓÐ5È˻ظ´
¡¾ÇóÖú¡¿ÓÐÈËÔÚ×ö½¹Á×Ëá²âÐòô£¿Ï£ÍûµÃµ½´óϺµÄ°ïÖú
ÒѾÓÐ13È˻ظ´
¡¾ÇóÖú/½»Á÷¡¿Ë«Ó«¹âËØÃ¸±¨¸æÏµÍ³³öÏÖ¼¸¸öÎÊÌ⣬Çó½â´ð£¬Ð»Ð»¡£
ÒѾÓÐ4È˻ظ´
¡¾ÇóÖú/½»Á÷¡¿luciferase assay
ÒѾÓÐ8È˻ظ´
¡¾ÇóÖú/½»Á÷¡¿Çë½ÌÓйØË«±¨¸æ»ùÒò¼ì²â
ÒѾÓÐ4È˻ظ´
³¾Ïãפ·ç
½ð³æ (СÓÐÃûÆø)
- Ó¦Öú: 7 (Ó×¶ùÔ°)
- ½ð±Ò: 712.5
- É¢½ð: 100
- ºì»¨: 4
- ɳ·¢: 1
- Ìû×Ó: 200
- ÔÚÏß: 61.3Сʱ
- ³æºÅ: 3077762
- ×¢²á: 2014-03-21
- רҵ: ÉúÎﻯѧ
4Â¥2014-07-21 20:42:28
ÏĶûlist
½ð³æ (ÖøÃûдÊÖ)
- BioEPI: 1
- Ó¦Öú: 121 (¸ßÖÐÉú)
- ½ð±Ò: 1095.8
- É¢½ð: 474
- ºì»¨: 5
- Ìû×Ó: 1200
- ÔÚÏß: 288.3Сʱ
- ³æºÅ: 1174302
- ×¢²á: 2010-12-21
- רҵ: ÊýÂÛ
3Â¥2014-07-21 18:48:20
³¾Ïãפ·ç
½ð³æ (СÓÐÃûÆø)
- Ó¦Öú: 7 (Ó×¶ùÔ°)
- ½ð±Ò: 712.5
- É¢½ð: 100
- ºì»¨: 4
- ɳ·¢: 1
- Ìû×Ó: 200
- ÔÚÏß: 61.3Сʱ
- ³æºÅ: 3077762
- ×¢²á: 2014-03-21
- רҵ: ÉúÎﻯѧ
|
ÇëÎÊÄãÓÃÕâ¸ö¼ì²âµÄʱºòÊǶàÑùÆ·»¹ÊÇÉÙÑùÆ·£¬ÎÒ¿´Ëü˵Ã÷ÊéÉÏ˵µÄÊÇ·¢¹âÖÁÉÙ³ÖÐøÒ»·ÖÖÓ£¬ÄÇô»á²»»áµÈ¼ÓÍêÈ«²¿µÄʱºòÇ°Ãæ¼ÓµÄ¾Í¿ªÊ¼Ë¥ÍËÁËÄØ£¿ |
» ±¾ÌûÒÑ»ñµÃµÄºì»¨£¨×îÐÂ10¶ä£©
5Â¥2014-07-22 09:16:43
ssssllllnnnn
ÖÁ×ðľ³æ (ÖªÃû×÷¼Ò)
Translator and Proofreader
- Ó¦Öú: 452 (˶ʿ)
- ½ð±Ò: 31580.9
- ºì»¨: 100
- Ìû×Ó: 7681
- ÔÚÏß: 19966.6Сʱ
- ³æºÅ: 3328089
- ×¢²á: 2014-07-17
- רҵ: Ö×Áö·¢Éú
¡ï
Сľ³æ: ½ð±Ò+0.5, ¸ø¸öºì°ü£¬Ð»Ð»»ØÌû
Ëͺ컨һ¶ä
Сľ³æ: ½ð±Ò+0.5, ¸ø¸öºì°ü£¬Ð»Ð»»ØÌû
Ëͺ컨һ¶ä |
These kind of assays are usually done with a Luminescence Microplate Reader. All you need to do is to prepare your cell lysates and add them to a 96-well plate. Then the machine will read the plate for you. The machine reads well by well in the plate and will inject the Stop & Glo reagents right before reading.... You can do it manually if you can't fine the machine. In this case, you have to add the reagents by yourself and read the samples right away. It's time-consuming though. If you do such experiments as transient transfection and transactivation assays, you need cotransfect a control reporter (Renilla series). That's the reason that you need a dual-luciferase assay system. |
6Â¥2014-07-22 11:47:10














»Ø¸´´ËÂ¥