| ²é¿´: 899 | »Ø¸´: 0 | |||
yiqinľ³æ (ÕýʽдÊÖ)
|
[½»Á÷]
Éú»¯×¨ÒµÊõÓïÖ®Ó¢ÎÄ·Òë
|
|
»¯ ѧ ´¿ ÊÔ ¼Á CP Chemical pure ʵ Ñé ÊÔ ¼Á LR Laboratory reagent ´¿ Pur Pure, Purum ÌØ ´¿ EP Extra Pure ÌØ ´¿ Puriss Purissimum ¾« ÖÆ Purif Puirfed Éú »¯ ÊÔ ¼Á BC Biochemical Éú Îï ÊÔ ¼Á BR Biological reagent Éú Îï Ⱦ É« ¼Á BS Biological stain Éú Îï ѧ Óà FBP For biological purpose ×é Ö¯ Åà Ñø Óà £¨ÎÞ¼ò³Æ£© For tissue medium purpose ΢ Éú Îï Óà FMB For microbiological ÏÔ Î¢ ¾µ Óà FMP For microscopic purpose µç ×Ó ÏÔ Î¢ ¾µ Óà £¨ÎÞ¼ò³Æ£© For electron microscopy Í¿ ¾µ Óà FLB For lens blooming ¹¤ Òµ Óà Tech Technical grade ʵ ϰ Óà Pract Practical use ·Ö Îö Óà PA Pro analysis ¾« ÃÜ ·Ö Îö Óà SSG Super special grade ºÏ ³É Óà FS For synthesis ÉÁ ˸ Óà Scint For scintillation µç Ó¾ Óà £¨ÎÞ¼ò³Æ£© For electrophoresis use ²â ÕÛ ¹â ÂÊ Óà RI For refractive index ÏÔ É« ¼Á £¨ÎÞ¼ò³Æ£© Developer ÑÐ ¾¿ ¼¶ £¨ÎÞ¼ò³Æ£© Research grade Ö¸ ʾ ¼Á Ind Indicator Âç ºÏ Ö¸ ʾ ¼Á £¨ÎÞ¼ò³Æ£© Complexon indicator Ó« ¹â Ö¸ ʾ ¼Á £¨ÎÞ¼ò³Æ£© Fluorescene indicator Ñõ »¯ »¹ Ô Ö¸ ʾ ¼Á Redox Redox indicator Îü ¸½ Ö¸ ʾ ¼Á Adsorb Adsorption indicator »ù ×¼ ÊÔ ¼Á PT Primary reagent ¹â Æ× ´¿ SP Spectrum pure ¹â Æ× ±ê ×¼ Îï ÖÊ SSS Spectrographic standard substance ·Ö ¹â ´¿ UV Ultra violet pure Ô ×Ó Îü ÊÕ ¹â Æ× AAS Atomic absorption spectrum ºì Íâ Îü ÊÕ ¹â Æ× IR Infrared absorption spectrum ºË ´Å ¹² Õñ ¹â Æ× NMR Nuclear magnetic resonance spectrum ÓÐ »ú ·Ö Îö ±ê ×¼ OAS Organic analytical standard ΢ Á¿ ·Ö Îö ÊÔ ¼Á MAR Micro analytical reagent µã µÎ ÊÔ ¼Á STR Spot-test reagent Æø Ïà É« Æ× GC Gas chromatography Òº Ïà É« Æ× LC Liquid chromatography Æø Òº É« Æ× GLC Gas liquid chromatography Æø ¹Ì É« Æ× GSC Gas solid chromatography ²ã Îö Óà FCP For chromatography purpose ±¡ ²ã É« Æ× TLC Thin layer chromatography |
» ²ÂÄãϲ»¶
Ò»Ö¾Ô¸085802 323·ÖÇóµ÷¼Á
ÒѾÓÐ11È˻ظ´
ɽ¶«Ë«·ÇԺУ¿¼ºË³¬¼¶ÎÞµ×Ïߣ¬Áìµ¼ÐÒÔÖÀÖ»ö£¬½ÌʦÔâÑê¿Ö
ÒѾÓÐ7È˻ظ´
279ѧ˶ʳƷרҵÇóµ÷¼ÁԺУ
ÒѾÓÐ17È˻ظ´
Ò»Ö¾Ô¸°²´óÉúÎïѧ07³õÊÔ322¡¢±¾¿Æ¶þ±¾¡¢µ÷¼ÁÇóÖú
ÒѾÓÐ9È˻ظ´
Ò»Ö¾Ô¸Õã´óÉúÎï325·ÖÇóµ÷¼Á
ÒѾÓÐ7È˻ظ´
»¯Ñ§070300 Çóµ÷¼Á
ÒѾÓÐ9È˻ظ´
085600²ÄÁÏÓ뻯¹¤349·ÖÇóµ÷¼Á
ÒѾÓÐ5È˻ظ´
297¹¤¿Æ£¬Çóµ÷¼Á?
ÒѾÓÐ6È˻ظ´
¿¼ÑÐÇóµ÷¼Á
ÒѾÓÐ3È˻ظ´
²ÄÁÏÏà¹Ø×¨Òµ344Çóµ÷¼ÁË«·Ç¹¤¿ÆÑ§Ð£»ò¿ÎÌâ×é
ÒѾÓÐ8È˻ظ´
ÕÒµ½Ò»Ð©Ïà¹ØµÄ¾«»ªÌû×Ó£¬Ï£ÍûÓÐÓÃŶ~
Çó·ÒëÒ»ÏÂÕâ¸öרҵ´Ê»ã
ÒѾÓÐ5È˻ظ´
רҵ²úÆ·´Ê»ã·Òë
ÒѾÓÐ1È˻ظ´
¹ØÓÚ²úÆ·¿ª·¢¹ý³ÌµÄ¼¸¸öרҵÊõÓï Çó·Òë
ÒѾÓÐ7È˻ظ´
Çó°ïæ·Òëһϣ¬ºÃ¶àרҵÊõÓï¿´²»¶®
ÒѾÓÐ4È˻ظ´
ÓÐûÓÐרҵµÄ£¨µç×Ó¼¶²£Á§ÏËά£©²ÄÁÏ·ÒëÈí¼þ»òÕßÍøÕ¾..Ö®ÀàµÄ´Ù½øÀí½âµÄ
ÒѾÓÐ2È˻ظ´
ÇóÖú½ðÊôרҵÎÄÏ׵öÃû´Ê·Ò룬·Ç³£¸Ðл
ÒѾÓÐ3È˻ظ´
¡¾×ªÔØ¡¿ÊýѧרҵӢÓïµç×Ӵʵ估רҵ´Ê»ã·Ò룡¡¾ÒÑËÑÎÞÖØ¸´¡¿
ÒѾÓÐ416È˻ظ´
Ë®ÄཬÌåÏà¹Ø×¨ÒµÃû´Ê·Òë
ÒѾÓÐ3È˻ظ´
¹ØÓڵ绯ѧÖеÄרҵÊõÓïµÄ·Òë
ÒѾÓÐ5È˻ظ´
Ò½Ò©·½ÃæµÄ£¬»ù½ðÉêÇëÖÐÒ»¸öÓ¢ÎÄÊõÓïÔõô·Ò룿´ó¼ÒÌÖÂÛÏ¡¾ÇóÖú½áÊø¡¿
ÒѾÓÐ4È˻ظ´
Çó¸ßÊÖ½«ÒÔÏÂcomputational method·Òë³ÉÖÐÎÄ£¬×¨ÒµÊõÓïÌ«¶à²»ÖªµÀÔõô·Òë
ÒѾÓÐ11È˻ظ´
ÓÐľÓÐͬѧ֪µÀ±È½ÏºÃµÄרҵÊõÓï·ÒëÈí¼þÄØ£¨Ó¢->ÖУ©
ÒѾÓÐ4È˻ظ´
ÌýÁ¦£¬Ð´×÷£¬·Ò룬Óï·¨£¬´Ê»ãµÈÓ¢Óï×ÊÁϴ󼯺Ï!!
ÒѾÓÐ202È˻ظ´
Ó¢ÓïÃû´Ê½âÊÍ¡£¡£¡£moving three-phase contact line ÊÇʲôÒâ˼
ÒѾÓÐ6È˻ظ´
¡¾ÇóÖú/½»Á÷¡¿ÇóÉúÎïרҵ·ÒëÈí¼þ£¨ÓÈÆäÊÇÉú»¯£©
ÒѾÓÐ4È˻ظ´
¡¾ÇóÖú¡¿Ö×ÁöÁÙ´²Ïà¹Ø×¨ÒµÊõÓïÓ¢ÎÄ·Òë
ÒѾÓÐ5È˻ظ´
¿ÆÑдÓСľ³æ¿ªÊ¼£¬ÈËÈËΪÎÒ£¬ÎÒΪÈËÈË













»Ø¸´´ËÂ¥
µã»÷ÕâÀïËÑË÷¸ü¶àÏà¹Ø×ÊÔ´