24小时热门版块排行榜    

CyRhmU.jpeg
查看: 1538  |  回复: 9
当前只显示满足指定条件的回帖,点击这里查看本话题的所有回帖

vipjhy

银虫 (小有名气)

[求助] 国外药典中有机杂质计算?

Standard solution: 3.6 µg/mL USP # RS in Mobile phase
Sample solution: Equivalent to 1.2 mg/mL of # in Mobile phase from NLT 20 Tablets finely crushed. [NOTE—Sonicate if necessary, and centrifuge the solution before passing through a suitable filter. ]
Calculate the percentage of each impurity in the portion of Tablets taken:
Result = (rU/rS) × (CS/CU) × (1/F) ×100
rU        = peak response of each impurity from the Sample solution
rS        = peak response of # from the Standard solution
CS        = concentration of USP # RS in the Standard solution (mg/mL)
CU        = nominal concentration of # in the Sample solution (mg/mL)
F        = relative response factor as listed in Impurity Table 1
疑问:这个计算方法到底属于外标法,还是自身对照?
回复此楼
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

XiaOliAngeR

木虫 (小有名气)

【答案】应助回帖


vipjhy: 金币+1, 有帮助 2012-08-22 15:10:09
引用回帖:
6楼: Originally posted by vipjhy at 2012-08-22 07:31:56
可是,主成分自身对照,不应该是将供试品稀释成自身对照吗?
...

样品主成分和法定对照品的主成分,你觉得用哪个更可靠,有时候我们国内的做法是不如人家国外的,但不能因此认为国外跟国内的做法有本质上的区别。
从检验成本来考虑国内都是采用前者,可以说国外的做法是精益求精吧。
9楼2012-08-22 12:24:23
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖
查看全部 10 个回答

abc123111

金虫 (小有名气)

【答案】应助回帖


感谢参与,应助指数 +1
痴夷子皮: 金币+1, 谢谢交流,欢迎常来哦。 2012-08-21 15:51:17
这个标准应该出自USP里面,去看看EP,JP等其他老外相应标准,会更让你清晰。

如果没猜错。  EP里面收载很可能是 自身对照法。

看是外标法,不过你可以参考EP改成自身对照
在论坛里收益颇丰,因此有空就尽量给站友一个参考
2楼2012-08-21 10:41:56
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

jinshuping

木虫 (小有名气)

【答案】应助回帖


感谢参与,应助指数 +1
痴夷子皮: 金币+1, 谢谢交流,欢迎常来哦。 2012-08-21 15:51:25
当然是外表法了,而且是加校正因子的主成分外表法
3楼2012-08-21 14:38:28
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

XiaOliAngeR

木虫 (小有名气)

【答案】应助回帖


感谢参与,应助指数 +1
痴夷子皮: 金币+1, 谢谢交流,欢迎常来哦。 2012-08-21 15:51:30
加校正因子的主成分自身对照法
上面说外标法的根本没有真正理解什么是外标法:首先外表法没有校正因子之说,然后外表法算杂质需要杂质对照品而不是上面给的主药对照品

[ 发自手机版 http://muchong.com/3g ]
4楼2012-08-21 15:46:11
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖