| ²é¿´: 924 | »Ø¸´: 2 | |||
mcfly2008гæ (³õÈëÎÄ̳)
|
[ÇóÖú]
¹ØÓÚ¼ì³öÏÞ£¬ÈçºÎÕÛËãµ½ÑùÆ·ÖÐÈ¥£¿ ÒÑÓÐ1È˲ÎÓë
|
|
×î½üͶÁËһƪ¸å¼þ£¬¹ØÓÚICP-MS²â¶¨¶àÔªËØµÄ£¬Éó¸åÒâ¼û¹ØÓÚLODµÄ£¬ÒÔǰÈÏΪËã³öÒÇÆ÷µÄLOD£¬È»ºóÕÛËã»ØÑùÆ·£¨°´¶¨ÈÝÌå»ý£¬³ÆÑùÁ¿£©£¬¾ÍÊÇ·½·¨µÄLOD£¬ÍòÍòûÏëµ½£¬Éó¸åÈ˸øÁËÎÒÒâ¼ûÈçÏ£º However, calling it a limit of detection is not a correct use of terminology. LOD is an instrumental terminology, it does not refer to samples. I think you should probably find another way to explain it. ÇëÎÊÎÒ¸ÃÔõôÏë°ì·¨£¬ÕÛËãµ½ÑùÆ·È¥ÄØ£¿ |
» ²ÂÄãϲ»¶
Ò»Ö¾Ô¸±±¾©Àí¹¤´óѧ±¾¿Æ211²ÄÁϹ¤³Ì294Çóµ÷¼Á
ÒѾÓÐ8È˻ظ´
349Çóµ÷¼Á
ÒѾÓÐ6È˻ظ´
329Çóµ÷¼Á
ÒѾÓÐ9È˻ظ´
Çóµ÷¼ÁÒ»Ö¾Ô¸Î人Àí¹¤´óѧ²ÄÁϹ¤³Ì£¨085601£©
ÒѾÓÐ9È˻ظ´
327Çóµ÷¼Á
ÒѾÓÐ5È˻ظ´
ÇóÊÕÁô
ÒѾÓÐ5È˻ظ´
375Çóµ÷¼Á
ÒѾÓÐ4È˻ظ´
340Çóµ÷¼Á
ÒѾÓÐ6È˻ظ´
298Çóµ÷¼Á
ÒѾÓÐ3È˻ظ´
085601²ÄÁϹ¤³ÌÕÒµ÷¼Á
ÒѾÓÐ9È˻ظ´
» ±¾Ö÷ÌâÏà¹Ø¼ÛÖµÌùÍÆ¼ö£¬¶ÔÄúͬÑùÓаïÖú:
µç¸ÐñîºÏµÈÀë×ÓÌåÖÊÆ×ÒÇ£¨ICP-MS£©ºÍʯī¯Ô×Ó·Ö¹â¹â¶È¼ÆµÄ̽²â¾«¶ÈµÄ¶Ô±ÈÎÊÌâ
ÒѾÓÐ6È˻ظ´
ºá×ø±êΪ¶ÔÊý¼ì³öÏ޵ļÆË㣬three times standard deviation µ¥Î»ÊÇʲô
ÒѾÓÐ6È˻ظ´
¿Õ°×ÑùÆ·ÖÐŨ¶È½Ï¸ßʱ£¬Ôõôȷ¶¨·½·¨µÄ¼ì³öÏ޺Ͷ¨Á¿ÏÞ£¿
ÒѾÓÐ13È˻ظ´
¹ØÓÚ×îµÍ¼ì³öÏ޵ļÆËã
ÒѾÓÐ5È˻ظ´
É«Æ×·ÖÎöÖмì³öÏÞÔõôËãѽ
ÒѾÓÐ3È˻ظ´
ÆøÏàÉ«Æ×-ÖÊÆ×Öмì³öÏÞÔõôËã°¡£¿£¿
ÒѾÓÐ12È˻ظ´
±ê×¼ÇúÏßÓÃSÇúÏßÄâºÏÔõôËãÀíÂÛ¼ì³öÏÞ°¡£¿
ÒѾÓÐ3È˻ظ´
Å©²Ð·ÖÎöÖУ¬×îµÍ¼ì³öÏÞÔõô¸ö×ö·¨ºÍËã·¨£¿
ÒѾÓÐ7È˻ظ´
dzµICP¡ªMS¡¢ICP-AES¼°AASµÄÐÔÄܼ°Ó¦ÓÃ
ÒѾÓÐ5È˻ظ´
¡¾ÇóÖú¡¿ICP-AESµÄ¼ì³öÏÞÈçºÎËã
ÒѾÓÐ13È˻ظ´
klicking
ÖÁ×ðľ³æ (ÖøÃûдÊÖ)
- ACI: 9
- Ó¦Öú: 923 (²©ºó)
- ¹ó±ö: 0.652
- ½ð±Ò: 19319.5
- É¢½ð: 30
- ºì»¨: 149
- ɳ·¢: 1
- Ìû×Ó: 2337
- ÔÚÏß: 513.3Сʱ
- ³æºÅ: 1426293
- ×¢²á: 2011-10-03
- ÐÔ±ð: GG
- רҵ: Ò©Îï·ÖÎö
¡¾´ð°¸¡¿Ó¦Öú»ØÌû
¸Ðл²ÎÓ룬ӦÖúÖ¸Êý +1
|
¿ÉÒԲο¼£ºÍ¨¹ý¼¸·Ý¿Õ°×ÑùÆ·µÄ·ÖÎö£¬È»ºó¼ÆËãÆäÏìÓ¦ÖµµÄ±ê×¼²î£¬²â³ö·ÖÎö±³¾°ÏìÓ¦ÖµµÄ´óС¡£ £¨ICH Q2£¨R1£©£º6.3 Based on the Standard Deviation of the Response and the Slope The detection limit (DL) may be expressed as: DL = 3.3 ¦Ò/S where ¦Ò = the standard deviation of the response S = the slope of the calibration curve The slope S may be estimated from the calibration curve of the analyte. The estimate of ¦Ò may be carried out in a variety of ways, for example: 6.3.1 Based on the Standard Deviation of the Blank Measurement of the magnitude of analytical background response is performed by analyzing an appropriate number of blank samples and calculating the standard deviation of these responses. 6.3.2 Based on the Calibration Curve A specific calibration curve should be studied using samples containing an analyte in the range of DL. The residual standard deviation of a regression line or the standard deviation of y-intercepts of regression lines may be used as the standard deviation. £© |

2Â¥2014-10-16 09:28:23
51658173
гæ (СÓÐÃûÆø)
- Ó¦Öú: 1 (Ó×¶ùÔ°)
- ½ð±Ò: 102.2
- É¢½ð: 11
- Ìû×Ó: 70
- ÔÚÏß: 16.8Сʱ
- ³æºÅ: 2402900
- ×¢²á: 2013-04-05
- רҵ: ʳƷ¼Ó¹¤¼¼Êõ
3Â¥2016-12-23 21:29:11














»Ø¸´´ËÂ¥