各位大虫
超级电容器的容量计算跟恒流充放电曲线的斜率有关吗?投了一个文章,有个审稿人说容量跟斜率有关,我已经跟他解释了恒流充放电,只跟时间有关,用电流乘以时间除以电压窗口和质量就行,可是二审后的审稿意见中,审稿人还是纠结这个问题,我不知道是我理解错了还是他误会了,我想引文献解释但是又怕来来回回麻烦,顺应他的话又不知道怎么回复。就剩这一个意见小修了。各位虫友给点建议。
PS:这是审稿意见:The values of the specific capacitance are quite sensitive to the slope of the discharge curves. In the revised manuscript, the authors demonstrated that the capacitance value was derived according to Eq. 4, however, the authors should show whether the capacitance values are derived from the first half of the discharge curve, the second half, or the mean values on the basis of Eq. 4.
也有可能是我表述不好让审稿人误会了,下面是文章的句子
Fig. 8b shows the specific capacitance (Cs) of the electrode, which are calculated from Eq.4, where I was the applied current, ΔV was the potential range of charge-discharge, m was the mass of active material, Δt was the time of a charge or discharge process.
Cs=(IxΔt )/(ΔVxm) eq.4 |