| ²é¿´: 773 | »Ø¸´: 1 | |||
qiuqinglei5020
|
[ÇóÖú]
°¢ßßɳ°àÒºÏà·ÖÎöÌõ¼þ£¿
|
| ÓÐ×ö°¢ßßɳ°àµÄÂð£¿ÒºÏàÌõ¼þ°ïæ˵һÏ |
» ÊÕ¼±¾ÌûµÄÌÔÌûר¼ÍƼö
ÐÂÒ©Ñз¢×¢²áÉ걨 |
» ²ÂÄãϲ»¶
»ùÓÚAIÖÇÄÜËã·¨µÄ×°±¸½á¹¹¿É¿¿ÐÔ·ÖÎöÓëÓÅ»¯Éè¼Æ¼¼Êõ
ÒѾÓÐ0È˻ظ´
ÇóÖúÇóÖú
ÒѾÓÐ0È˻ظ´
Ò©ÎïѧÂÛÎÄÈóÉ«/·ÒëÔõôÊÕ·Ñ?
ÒѾÓÐ158È˻ظ´
ũҵ×ÊÔ´Óë»·¾³¡¢ÖÇ»Ûũҵרҵ±¾¿ÆÉú±ÏÒµÂÛÎÄ¿ÎÌâÑ¡ÌâÇóÖú
ÒѾÓÐ1È˻ظ´
È˹¤ÖÇÄܸ³ÄܾۺÏÎï¼°¸´ºÏ²ÄÁÏÄ£ÐÍÓ¦ÓÃÓëʵ¼ù
ÒѾÓÐ0È˻ظ´
¸÷¹úºÍ¹ú¼Ê×éÖ¯ÏÖÐÐÒ©µä×¢ÉäÓÃË®ÖÊÁ¿±ê×¼
ÒѾÓÐ0È˻ظ´
ÇóÖúÓÃ΢Æ×Êý¾Ý¿â²éѯ
ÒѾÓÐ0È˻ظ´
¼ÆË㻯ѧÓëÈ˹¤ÖÇÄÜÇý¶¯µÄMOFsÐÔÄÜÔ¤²âÓëɸѡ¼¼Êõ
ÒѾÓÐ0È˻ظ´
ÑÐÈýʵÑéÇóÖ¸µ¼
ÒѾÓÐ0È˻ظ´
½ðÊô²ÄÁ϶à³ß¶È¼ÆËãÄ£Äâ¼¼ÊõÓëÓ¦ÓãºÎ¢¹Û»úÀíµ½ºê¹ÛÐÔÄܵɹ¤×÷
ÒѾÓÐ0È˻ظ´
½Î÷¿Æ¼¼Ê¦·¶´óѧ΢ÉúÎïÌìȻҩÎïÀÏʦ½éÉÜ
ÒѾÓÐ23È˻ظ´
» ±¾Ö÷ÌâÏà¹Ø¼ÛÖµÌùÍÆ¼ö£¬¶ÔÄúͬÑùÓаïÖú:
µº½òÒºÏàÉ«Æ×һ̨£¬ÈçºÎ¶ÔÒÇÆ÷ºÍ·ÖÎöÌõ¼þ½øÐÐÉèÖã¬Ê¹·åÃæ»ýÔö´ó£¿£¿
ÒѾÓÐ11È˻ظ´
ÒºÏàÉ«Æ×²â¶¨±½·ÓµÄŨ¶ÈµÄÌõ¼þ¼°Öù×ÓÀàÐÍ
ÒѾÓÐ12È˻ظ´
¡¾ÇóÖú¡¿¹ØÓÚÓлúÑÎÀàũҩµÄÒºÏà¼ì²âʱҺÏàÉ«Æ×ÖùÑ¡Ôñ¼°ÆäÉ«Æ×Ìõ¼þ
ÒѾÓÐ8È˻ظ´
ÒºÏàÉ«Æ×µÄ°²×°Ìõ¼þÒªÇó£¬ÌرðÊÇ»·¾³ÒªÇó
ÒѾÓÐ5È˻ظ´
ÒºÏàÉ«Æ×·ÖÀëÌõ¼þµÄÓÅ»¯
ÒѾÓÐ9È˻ظ´
±½ôû£¨ÁÚ±½¶þ¼×Ëáôû£©ÒºÏà·ÖÎöµÄÌõ¼þ£¡£¡£¡
ÒѾÓÐ14È˻ظ´
ºúÂܲ·ËØÒºÏàÌõ¼þ£º°²½ÝÂ×1260·´ÏàC18É«Æ×Öù
ÒѾÓÐ14È˻ظ´
ÇóÖú£ºÎåÂÈ·ÓÄÆµÄ¸ßЧҺÏàÉ«Æ×µÄÌõ¼þ£¿
ÒѾÓÐ6È˻ظ´
ÑùÆ·¼ì²â ²»ÖªµÀÒºÏàÌõ¼þÔõôѡÔñ£¿£¿Ð»Ð»£¡£¡£¡
ÒѾÓÐ5È˻ظ´
¡¾ÇóÖú¡¿ÒºÏàÉ«Æ×É«Æ×Ìõ¼þÑ¡ÔñÎÊÌ⣬лл£¡
ÒѾÓÐ3È˻ظ´
¡¾ÇóÖú¡¿ÇóÖú£ºÔÚESIÀë×ÓÔ´Ìõ¼þÏ£¬ÒºÏàÁ÷¶¯ÏàµÄÅä֯ӦעÒâÄÄЩÎÊÌâ?
ÒѾÓÐ8È˻ظ´
¡¾ÇóÖú¡¿ÒºÏà·ÖÀëÌõ¼þɸѡ³öÀ´ºó£¬½øÐÐÖÊÆ×·ÖÎö£¬ÖÊÆ×ÏìÓ¦³Ì¶ÈµÄÓ°ÏìÒòËØÓÐÄÄÐ©ÄØ£¿
ÒѾÓÐ5È˻ظ´
¡¾ÇóÖú¡¿ÒºÖÊÁªÓ÷ÖÎöÖжÔÒºÏàÉ«Æ×Ìõ¼þµÄÁ÷¶¯ÏàÓÐʲô¾ßÌåµÄÒªÇó£¿
ÒѾÓÐ4È˻ظ´
yanghuping
ľ³æ (ÕýʽдÊÖ)
- Ó¦Öú: 100 (³õÖÐÉú)
- ½ð±Ò: 5103.5
- É¢½ð: 2331
- ºì»¨: 8
- ɳ·¢: 1
- Ìû×Ó: 939
- ÔÚÏß: 1099.3Сʱ
- ³æºÅ: 965040
- ×¢²á: 2010-03-08
- ÐÔ±ð: GG
- רҵ: ÓлúºÏ³É
¡¾´ð°¸¡¿Ó¦Öú»ØÌû
¸Ðл²ÎÓ룬ӦÖúÖ¸Êý +1
|
ÓÐһƪÎÄÏ×ÉÏÃæµÄ·ÖÎöÌõ¼þ£ºGeneral Experimental: All reagents used were of ACS grade or higher. Flash chromatography was performed using either a Biotage Flash Chromatography System or an AnaLogix BSR Solvent Pump System with silica gel cartridges. HPLC analyses for the syntheses were performed on an Agilent 1100 HPLC system including solvent degasser, pump, automated injector and variable UV detector connected to either an IN/US BetaRam Flow Detector with a 0.25ml detector cell or a Berthold Scintillation Detector with a 0.5 ml detector cell. HPLC gradient 1 = Phenomenex Luna C18, 5 mm, 4.6150mm column. Mobile phase A = 0.05% TFA in water, mobile phase B = 0.05% TFA in acetonitrile, 0min 95% A, 6min 50% A, 11 min 95% B, 13 min 95% B, 15 min 95% A, UV detection at 254 nm. HPLC gradient 2 = Vydac protein and peptide C18, 4.6250mm column. Mobile phase A= 0.05% TFA in water, mobile phase B = 0.05% TFA in acetonitrile, 0min 90% A, 16 min 90% B, 23 min 95% B, 25 min 90% A, UV detection at 254 nm. HPLC Gradient 3 = Phenomenex, Luna, C18 (2), 3 mm, 1504.6mm column with Brownlee, RP-18 C18, 3 mm, 153.2mm guard column, column temperature = 301C, autosampler temperature = 41C, mobile phase A = 0.4% formic acid in water adjusted to pH 3.2 with NH4OH, mobile phase B = acetonitrile, mobile phase C = MeOH, 0 min 100% A, 25 min 20% A and 80% B, 27min 50% B and 50% C, 32 min 50% B and 50% C, 34 min 100% A, flowrate = 1.0ml/min at 323 nm. HPLC Gradient 4 =Ace 3, C18, 3 mm, 1504.6mm column with Ace 3, C18, 3 mm, 103.0mm guard column, column temperature = 351C, autosampler temperature = ambient, mobile phase A = 0.4% formic acid in water, adjusted to pH 3.2 with NH4OH, mobile phase B = acetonitrile, 0min 100% A, 3min 100% A, 5min 90% A, 20 min 75% A, 50 min 75% A, 60 min 50% A, 65 min 100% B, 70 min 100% B, 72 min 100% A, flowrate = 0.7ml/min, UV detection at 240 nm. Preparative HPLC condition 1: Phenomenex Luna 5 mm, 25021.2mm column. Mobile phase A = 0.1% TFA in water, mobile phase B = 0.1% TFA in acetonitrile, 0 min 70% A, 18 min 95% B, 22 min 95% B, 25 min 70% A, flowrate = 15 ml/min. UV detection at 254 nm. Preparative HPLC condition 2: Zorbax SB-C18 5 mm, 25021.2mm column. Mobile phase A = 0.05% TFA in water, mobile phase B = 0.05% TFA in acetonitrile, 0 min 90% A, 16 min 90% B, 23 min 95% B, 25 min 90% A, Flowrate = 9.9ml/min, UV detection at 254 nm. LC/MS analysis was performed on a Finnigan LXQ Mass Spectrometer System. NMR spectra were recorded on a Bruker AVANCE II 300MHz Spectrometer with an UltrashieldTM Magnet or a Varian Unity/Inova 300MHz Spectrometer. Specific activities were performed gravimetrically. Liquid scintillation counting was performed on either a PerkinElmer Tri-Carb Model 2900Tr or a Wallac Model 1409 Liquid Scintillation Counter. |
» ±¾Ìû¸½¼þ×ÊÔ´Áбí
-
»¶Ó¼à¶½ºÍ·´À¡£ºÐ¡Ä¾³æ½öÌṩ½»Á÷ƽ̨£¬²»¶Ô¸ÃÄÚÈݸºÔð¡£
±¾ÄÚÈÝÓÉÓû§×ÔÖ÷·¢²¼£¬Èç¹ûÆäÄÚÈÝÉæ¼°µ½ÖªÊ¶²úȨÎÊÌ⣬ÆäÔðÈÎÔÚÓÚÓû§±¾ÈË£¬Èç¶Ô°æÈ¨ÓÐÒìÒ飬ÇëÁªÏµÓÊÏ䣺xiaomuchong@tal.com - ¸½¼þ 1 : 1890_ftp.pdf
2013-10-17 15:46:21, 998.45 K
2Â¥2013-10-17 15:43:13














»Ø¸´´ËÂ¥
50