| ²é¿´: 1068 | »Ø¸´: 3 | ||
΢΢ÌìÀ¶Ìú³æ (³õÈëÎÄ̳)
|
[ÇóÖú]
Çë¸ßÊÖ¸ù¾Ý±à¼Òâ¼û°ïÎÒ¾«ÐÞһϵ¥¾§°É£¬ÏÈллÀ²
|
ÎÒÊÇÐÂÊÖ£¬±à¼¸øµÄÒâ¼ûºÃ¶à£¬ÎÒÍêÈ«²»ÖªµÀ¸ÃÔõôÏÂÊÖÀ²![]() ¶øÇÒÎÒҲûÓÐSHELXTLÈí¼þ¡£°ï°ïæ°É£¬ÐèҪʲôÎļþÇë¸úÎÒ˵£¬ÏÖÔÚÎÒÊÇһͷÎíË®ÁË¡£ ÒÔÏÂÊDZà¼Òâ¼û£º£¨ºÃ³¤°¡£¬Í·ÔÎ £©1. The "_diffrn_measured_fraction_theta_full" is too low. I note you have cut off your reflection file at theta = 25.1 deg yet your unit cell determination uses reflections up to theta = 27.69 deg. I include a quote from CheckCIF relative to this point: " Ideally (and a requirement for publication in Acta Crystallographica), this fraction should be close to 1.0 for theta-full greater or equal to sin(theta/lambda) = 0.6 (i.e. 25.24 degrees for MoKa and 67.7 degrees for CuKa radiation). The three major causes of incomplete data sets are: 1 - A missing cusp of data due to data collection by rotation around the spindle axis only (standard on some image-plate systems). Cure: collect an additional data set after remounting the crystal. 2 - The DENZO imageprocessing package has problems with certain strong reflections. They are often excluded from the data set. Cure: Add an additional scan at lower power setting in order to include strong low order reflections. 3 - Incomplete scans, possibly based on erroneously assumed higher than actual symmetry." Thus your theta(max) cutoff is too low and this may be part of the problem. I am also puzzled by the small number of reflections collected. Did you collect a full sphere of data? With an APEX-II that shouldn't take an inordinate amount of time. If your present data set doesn't have enough measurable data so that you can get "_diffrn_measured_fraction_theta_full" above 0.99 at theta = 25.24 deg, it will be necessary to recollect the data using longer scan times and/or at low temperature. 2. It appears that the reflection 1 0 0 is obscured by the beamstop and should be omitted from the final refinement. 3. Please be certain that your final weighting scheme is correct (I get different values than you report in my test refinement). 4. Your Fig. 2 needs to be redrawn using circles or only the outlines of the ellipsoids, not full ellipsoids, and should include those H-atoms which are involved in the H-bonding. Also, the O2-H2...O3 interaction has too small an angle to be considered a true H-bond. |
» ²ÂÄãϲ»¶
¡¾¸ßУÁªºÏ¾Ù°ì¡¿2026ÄêµÚÎå½ì·þÎñ»úÆ÷È˹ú¼Ê»áÒ飨ICoSR 2026£©
ÒѾÓÐ0È˻ظ´
ÉîÛÚ´óѧ»¯Ñ§Óë»·¾³¹¤³ÌѧԺ³¬·Ö×ÓÍŶÓÕÐÊÕ2026¼¶ÉêÇë-¿¼ºËÖÆ²©Ê¿Éú
ÒѾÓÐ8È˻ظ´
ÎÞ»ú»¯Ñ§ÂÛÎÄÈóÉ«/·ÒëÔõôÊÕ·Ñ?
ÒѾÓÐ264È˻ظ´
ÖÐÄÏ´óѧ»¯Ñ§»¯¹¤Ñ§ÔºÒ×СÒÕ½ÌÊÚ¿ÎÌâ×éÕÐÊÕ2026¼¶²©Ê¿Ñо¿Éú£¨µÚ¶þÂÖ£©
ÒѾÓÐ0È˻ظ´
ÇóÖú
ÒѾÓÐ0È˻ظ´
0703»¯Ñ§26¿¼Ñе÷¼Á£¬Ò»Ö¾Ô¸Äϲý´óѧ
ÒѾÓÐ2È˻ظ´
ÓÐûÓл¯Ñ§¡¢²ÄÁÏרҵµÄͬѧÐèÒªµ÷¼Á ¿¼ÂÇÌì½ò¸ßЧµÄ¿ÉÒÔÓʼþ»òÕß˽ÐÅ
ÒѾÓÐ1È˻ظ´
26Ä격ʿÕÐÉú
ÒѾÓÐ15È˻ظ´
½Î÷Àí¹¤´óѧ¹¦Äܾ§Ì¬²ÄÁÏ·½ÏòÁõËì¾ü¿ÎÌâ×éÕÐÊÕ2026ÄêÇï¼¾Èëѧ²©Ê¿Ñо¿Éú
ÒѾÓÐ10È˻ظ´
ÄþÏÄ´óѧÍÅ´ØÐ²ÄÁÏÍŶÓÕÐÊÕ²ÄÁÏ/»¯Ñ§/»¯¹¤×¨Òµ²©Ê¿Éú
ÒѾÓÐ0È˻ظ´
» ±¾Ö÷ÌâÏà¹Ø¼ÛÖµÌùÍÆ¼ö£¬¶ÔÄúͬÑùÓаïÖú:
Çó¸ßÊÖ¾«ÐÞÏÂÒ»¸öµ¥¾§½á¹¹
ÒѾÓÐ4È˻ظ´
Çë¸ßÊÖÖ¸µãһϣ¬Ò»¸ö¼ÓÇâ¼ü¾«ÐÞµÄÎÊÌ⣬Èí¼þ¼ÓÇâ¼üºóÔËÐв»ÁË
ÒѾÓÐ15È˻ظ´
Çë½ÌRietveld¾«ÐÞµÄÒ»°ã²½ÖèÓë²ÎÊýÉèÖã¿
ÒѾÓÐ12È˻ظ´
40½ðÐüÉͽâ¾öÒ»¸öÂϾ§ÎÊÌ⣬µ¥¾§½á¹¹¾«ÐÞ¡£¡£¡£¡£
ÒѾÓÐ7È˻ظ´
Çë½ÌÒ»ÏÂÅäºÏÎïµ¥¾§ÈçºÎ¾«ÐÞ£¬ÓÃʲôÈí¼þ¾«ÐÞ¡£Ôõô¾«ÐÞ£¬²»ÊDZ¾×¨Òµ£¬·Ç³£Ð»Ð»
ÒѾÓÐ3È˻ظ´
Çó¸ßÊÖ¾«ÐÞ¾§Ìå²¢µÃµ½Çâ¼ü±í£¬±¾ÈË·Ç´Ëרҵ¡£·³Çë¸ßÊÖÇó½â
ÒѾÓÐ9È˻ظ´
³õѧÕßÇë¸÷λ¸ßÊÖ°ïæ¿´Ò»ÏÂGSAS¾«Ð޵Ľá¹û£¬ÇëÖ¸µã
ÒѾÓÐ14È˻ظ´
¡¾½»Á÷¡¿Çó½ÌXRD¸ßÊÖ°ïæ¿´¿´Õâ·ùͼXRD½â¹¹¾«ÐÞͼÊÇÔõôŪµÄ
ÒѾÓÐ10È˻ظ´
¡¾Çë½Ì¡¿Çë½ÌGSAS¾«ÐÞÎÊÌâ
ÒѾÓÐ14È˻ظ´
΢΢ÌìÀ¶
Ìú³æ (³õÈëÎÄ̳)
- Ó¦Öú: 0 (Ó×¶ùÔ°)
- ½ð±Ò: 18
- Ìû×Ó: 2
- ÔÚÏß: 1.1Сʱ
- ³æºÅ: 1472298
- ×¢²á: 2011-11-02
- רҵ: É«Æ×·ÖÎö
2Â¥2011-11-02 20:39:16
chilajiao
½ð³æ (ÖªÃû×÷¼Ò)
É¼Ò×åNo.1
- CMEI: 1
- Ó¦Öú: 10 (Ó×¶ùÔ°)
- ¹ó±ö: 0.723
- ½ð±Ò: 529.7
- É¢½ð: 4889
- ºì»¨: 51
- ɳ·¢: 27
- Ìû×Ó: 6887
- ÔÚÏß: 656.5Сʱ
- ³æºÅ: 575563
- ×¢²á: 2008-06-18
- רҵ: Åäλ»¯Ñ§

3Â¥2011-11-03 08:55:01
chilajiao
½ð³æ (ÖªÃû×÷¼Ò)
É¼Ò×åNo.1
- CMEI: 1
- Ó¦Öú: 10 (Ó×¶ùÔ°)
- ¹ó±ö: 0.723
- ½ð±Ò: 529.7
- É¢½ð: 4889
- ºì»¨: 51
- ɳ·¢: 27
- Ìû×Ó: 6887
- ÔÚÏß: 656.5Сʱ
- ³æºÅ: 575563
- ×¢²á: 2008-06-18
- רҵ: Åäλ»¯Ñ§

4Â¥2011-11-03 09:48:53














£©
»Ø¸´´ËÂ¥