| ²é¿´: 1466 | »Ø¸´: 4 | |||
| ±¾Ìû²úÉú 1 ¸ö ·ÒëEPI £¬µã»÷ÕâÀï½øÐв鿴 | |||
| µ±Ç°Ö»ÏÔʾÂú×ãÖ¸¶¨Ìõ¼þµÄ»ØÌû£¬µã»÷ÕâÀï²é¿´±¾»°ÌâµÄËùÓлØÌû | |||
denvoll½ð³æ (ÕýʽдÊÖ)
¶ÀÁ¢µÄ´°Íâ¿Í
|
[ÇóÖú]
»¯Ñ§¹âÆ×·ÖÎö£¬ººÒëÓ¢
|
||
|
¶ÔµÍºÏ½ð¸ÖÖжàÔªËØ²â¶¨µÄ»Ô¹â·ÅµçÔ×Ó·¢Éä¹âÆ×·¨£¬X-ÉäÏßÓ«¹â¹âÆ×·¨£¬µç¸ÐñîºÏµÈÀë×ÓÌåÔ×Ó·¢Éä¹âÆ×·¨£¬»ð»¨Ô´Ô×Ó·¢Éä¹âÆ×·ÖÎö·½·¨¹ú¼Ò±ê×¼ÖеÄÔÙÏÖÐÔÖµºÍÖØ¸´ÐÔÖµ±È½Ï£¬Êý¾Ý±íÃ÷»Ô¹â·ÅµçÔ×Ó·¢Éä¹âÆ×·¨µÄÔÙÏÖÐԽϺ㬶øÖظ´ÐÔÏà¶ÔÆ«¸ß¡£×îºó»Ô¹â·Åµç¹âÆ×¼¼ÊõµÄÓÅµã½øÐÐ×ܽᣬ²¢¶ÔÖÆÔ¼»Ô¹â·Åµç¹âÆ×¼¼Êõ·¢Õ¹µÄÒòËØ½øÐÐÁË̽ÌÖ¡£ [ Last edited by denvoll on 2011-6-12 at 16:09 ] |
» ²ÂÄãϲ»¶
288Çóµ÷¼Á
ÒѾÓÐ5È˻ظ´
281Çóµ÷¼Á£¨0805£©
ÒѾÓÐ19È˻ظ´
²ÄÁÏ¿¼Ñе÷¼Á
ÒѾÓÐ3È˻ظ´
346Çóµ÷¼Á[0856]
ÒѾÓÐ6È˻ظ´
294Çóµ÷¼Á²ÄÁÏÓ뻯¹¤×¨Ë¶
ÒѾÓÐ9È˻ظ´
328Çóµ÷¼Á£¬Ó¢ÓïÁù¼¶551£¬ÓпÆÑоÀú
ÒѾÓÐ12È˻ظ´
Ò»Ö¾Ô¸Î÷°²½»Í¨´óѧ²ÄÁϹ¤³Ìרҵ 282·ÖÇóµ÷¼Á
ÒѾÓÐ5È˻ظ´
085601²ÄÁϹ¤³Ìר˶Çóµ÷¼Á
ÒѾÓÐ7È˻ظ´
321Çóµ÷¼Á
ÒѾÓÐ6È˻ظ´
Ò»Ö¾Ô¸Öк£Ñó²ÄÁϹ¤³Ìר˶330·ÖÇóµ÷¼Á
ÒѾÓÐ7È˻ظ´

lxh419
½ð³æ (ÕýʽдÊÖ)
¶À¹ÂÇó°Ü
- ·ÒëEPI: 3
- Ó¦Öú: 2 (Ó×¶ùÔ°)
- ½ð±Ò: 1098.3
- É¢½ð: 587
- ºì»¨: 3
- Ìû×Ó: 643
- ÔÚÏß: 189.6Сʱ
- ³æºÅ: 922156
- ×¢²á: 2009-12-07
- ÐÔ±ð: GG
- רҵ: µÈÀë×ÓÌåÎïÀí
¡¾´ð°¸¡¿Ó¦Öú»ØÌû
denvoll(½ð±Ò+20, ·ÒëEPI+1): ллÄãµÄ°ïÖú£¬¸Ðл¡£ 2011-06-14 19:19:31
| By compared the reproducibility and the repeatability values of glow discharge atomic emission spectrometry, X-ray fluorescence spectrometry, inductively coupled plasma atomic emission spectrometry, spark source atomic emission spectrometric analysis on the national standards of the multi-element determination of low-alloy steel, the data show (we found) that the reproducibility of glow discharge atomic emission spectrometry's reproducibility is good, and it's repeatability is relatively high. Finally, the advantages of glow discharge spectroscopy are summarised, and the factors of restricting the development of glow discharge spectroscopy are discussed. |

3Â¥2011-06-14 15:52:20
denvoll
½ð³æ (ÕýʽдÊÖ)
¶ÀÁ¢µÄ´°Íâ¿Í
- Ó¦Öú: 54 (³õÖÐÉú)
- ½ð±Ò: 2769.8
- ºì»¨: 2
- Ìû×Ó: 440
- ÔÚÏß: 78.5Сʱ
- ³æºÅ: 499352
- ×¢²á: 2008-02-09
- רҵ: ¹âÆ×·ÖÎö

2Â¥2011-06-14 14:30:57
Äߺ×ËÉ
ͳæ (³õÈëÎÄ̳)
- ·ÒëEPI: 3
- Ó¦Öú: 0 (Ó×¶ùÔ°)
- ½ð±Ò: 147
- É¢½ð: 5
- Ìû×Ó: 36
- ÔÚÏß: 10.4Сʱ
- ³æºÅ: 1312490
- ×¢²á: 2011-06-01
- ÐÔ±ð: GG
- רҵ: Ò£¸Ð»úÀíÓë·½·¨
¡¾´ð°¸¡¿Ó¦Öú»ØÌû
denvoll(½ð±Ò+20): ллÄãµÄ°ïÖú£¬¸Ðл¡£ 2011-06-14 19:20:08
|
This paper compared the national standard reproducibility and repeatability values among several methods that determined multi elements in low alloy steel, including glow discharge atomic emission spectrometry, X-ray fluorescence spectrometry, inductively coupled plasma atomic emission spectrometry and spark source atomic emission spectrum analysis. The data showed better reproducibility and relatively higher repeatability in glow discharge atomic emission spectrometry. Finally, the paper summarized the advantages of glow discharge spectroscopic technology, and discussed the factors that restricted its development. ÎûÎûÎû£¬ÎÒÒ²ÊÔÊÔ¡£ |
4Â¥2011-06-14 16:09:33
denvoll
½ð³æ (ÕýʽдÊÖ)
¶ÀÁ¢µÄ´°Íâ¿Í
- Ó¦Öú: 54 (³õÖÐÉú)
- ½ð±Ò: 2769.8
- ºì»¨: 2
- Ìû×Ó: 440
- ÔÚÏß: 78.5Сʱ
- ³æºÅ: 499352
- ×¢²á: 2008-02-09
- רҵ: ¹âÆ×·ÖÎö

5Â¥2011-06-14 19:21:22













»Ø¸´´ËÂ¥