¶þÉó±à¼Òâ¼û£ºThe reviewers and the editor believe that the paper requires a major editing effort to qualify. The Abstract contains numerous use-of-English errors as does the rest of the manuscript, which need to be corrected. The second reviewer has indicated several errors throughout the paper. The authors are advised to seek expert help in revising their manuscript as far as the use of English is concerned.
In addition, please respond to the following editor comment:
The STHS problem formulation (1) - (11) neglects the thermal unit commitment. The mathematical formulation (1) - (11) implies that all thermal units on-line during the entire scheduling period, which is nor correct. In addition, several standard thermal unit constraints, such as minimum up / down times, ramp rate limits, as well as system reserve requirements are missing from the STHS formulation. Please, rectify.
¶þÉóÉó¸åÈËÒâ¼û£ºÐÂÔöµÄÉó¸åÈËÌáÁËÒ»´ó¶ÑµÄÓï·¨¡¢Óï¾ä´íÎ󣨽ӽü30Ìõ£©¡£ÆäËûÉó¸åÈËû½²Ê²Ã´ÁË¡£
Õâ¸öÒâ¼ûÊDz»ÊÇÓ¦¸ÃËãСÐÞ°¡£¿
ÁíÍ⣬±à¼µÄµÚ¶þÌõÒâ¼û²»ÏëÐ޸ġ£²»ÏëÐÞ¸ÄÎÊÌâÄ£ÐÍ£¬ÒòΪһµ©Ð޸ģ¬ÎÊÌâÓÉÁ¬ÐøÐÍÓÅ»¯±äΪ»ìºÏÁ¬Ðø¡¢ÀëÉ¢ÐÍÓÅ»¯£¬ËùÌáµÄËã·¨£¨ÎÄÕµÄÖ÷Òª¹¤×÷ÔÚÓÚËã·¨£©¿Ï¶¨Òª×ö´óÁ¿Ð޸ģ¬Çҿ϶¨Òª²¹Ò»Ð©ÊµÑé¡£Èç¹û²»×öÐ޸쬏ÃÔõô»Ø¸´±à¼£¿»á²»»á°Ñ±à¼¸øÈÇ»ðÁË£¿·Ç³£¸Ðл¡£ |