| ²é¿´: 598 | »Ø¸´: 3 | |||
| ±¾Ìû²úÉú 1 ¸ö ·ÒëEPI £¬µã»÷ÕâÀï½øÐв鿴 | |||
[½»Á÷]
ÓÐÒ»¶ÎÓ¢ÎÄ·ÒëΪÖÐÎÄ
|
|||
| Both minnocycline and rifampin were deteced under the same separation conditions.The mobile phase cinsisted of KH2PO4(60%)and acetontrile(40%)with the final pH adjutsed to ~3.25 using 85% O-phosphoric acid.The HPL system was run under an isocratic reversed-phase condition with a flow rate of 1mL/min.Detection was done at a wavelength of 339 nm. Minocycine was eluted at 1.5 min,and rifamipin was detected at 13 min .In pilot trials,known amounts of antibiotics were added to 1-cm segments of uncoated catheters and extracted as outlined above.More than 90% of both antibiotics were recovered. After construction of standard curves,antibiotic cintrols were measured with a consistent accuracy of >85%. |
» ²ÂÄãϲ»¶
Çóµ÷¼Á
ÒѾÓÐ3È˻ظ´
265Çóµ÷¼Á
ÒѾÓÐ4È˻ظ´
085700×ÊÔ´Óë»·¾³308Çóµ÷¼Á
ÒѾÓÐ6È˻ظ´
Ò»Ö¾Ô¸¼ªÁÖ´óѧ²ÄÁÏѧ˶321Çóµ÷¼Á
ÒѾÓÐ12È˻ظ´
286·ÖÈ˹¤ÖÇÄÜרҵÇëÇóµ÷¼ÁÔ¸Òâ¿ç¿¼£¡
ÒѾÓÐ3È˻ظ´
329Çóµ÷¼Á
ÒѾÓÐ5È˻ظ´
ÉêÇë»Ø¸åÑÓÆÚÒ»¸öÔ£¬±à¼Í¬ÒâÁË¡£µ«ÏµÍ³ÉϵÄʱ¼äû±ä£¬¸ø±à¼ÓÖдÓʼþÁË£¬Ã»»Ø¸´
ÒѾÓÐ4È˻ظ´
²ÄÁÏѧ˶318Çóµ÷¼Á
ÒѾÓÐ5È˻ظ´
Ò»Ö¾Ô¸Öйúº£Ñó´óѧ£¬ÉúÎïѧ£¬301·Ö£¬Çóµ÷¼Á
ÒѾÓÐ6È˻ظ´
081700»¯¹¤Ñ§Ë¶µ÷¼Á
ÒѾÓÐ3È˻ظ´
» ÇÀ½ð±ÒÀ²£¡»ØÌû¾Í¿ÉÒԵõ½:
±¾×ÓÖÕÓÚÌá½»ÁË¡£²»ÓÃÔÙ¿´ÁË£¬Ò»ÇÐÏÐÏÂÀ´ÂýÂýµÈ¡£Ï£ÍûÒ»ÇÐ˳Àû£¡
+1/644
Öйú¿ÆÑ§Ôºº¼ÖÝҽѧÑо¿-³£ð©Ñо¿Ô±¿ÎÌâ×鲩ʿºóÕÐÆ¸
+1/284
¡¾¼¼Êõ·þÎñ¡¿Ñо¿ËùºáÏò¼¼Êõ¿ª·¢¼°·þÎñ
+1/98
É¢½ð±Ò£¬ÇóºÃÔË£¬×£ÃæÉÏ˳Àû£¡
+2/78
¡¾´úÈË·¢ÌûÎðÕ¾ÄÚÐÅ¡¿¡¾³É¶¼Õ÷ÄÐÓÑ¡¿89Äêδ»é²©Ê¿Æ¯ÁÁÅ®º¢
+1/69
¹âѧ¹¤³Ìѧ˶µ÷¼ÁÐÅÏ¢
+2/44
Ñо¿Éú µ÷¼Á ¿´¹ýÀ´- »úе¡¢¿ØÖƹ¤³Ì¡¢Á¦Ñ§ÀࣨÁ÷ÌåÁ¦Ñ§¡¢Ò»°ãÁ¦Ñ§µÈ£© 211 ˫һÁ÷
+1/36
2026ÄêÖØÇ칤ÉÌ´óѧ¹ÜÀí¿ÆÑ§Ó빤³ÌרҵѧÊõ˶ʿÕÐÉúµ÷¼Á£¬·ç¾°×ÜÔÚÁø°µ»¨Ã÷´¦
+1/35
1
+1/33
ÉϺ£½»´ó»¯Ôº¹¦ÄÜ´ó·Ö×ÓÍŶÓÕÐ2026Äê˶ʿ¡¢ÁªÅà¡¢²©Ê¿ºó
+1/32
2026ÄêÎ÷ÄϿƼ¼´óѧ¹¦ÄÜÍ¿²ã¿ÎÌâ×é¼ò½é
+1/11
¡¾Î人¸ßУ¡¿¡¾ÐÂÄÜÔ´²ÄÁÏÓëÆ÷¼þ¿ÎÌâ×é¡¿ ÕÐÊÕÓÅÐã˶ʿµ÷¼ÁÉú£¡£¡£¡
+5/10
½ÌÓý²¿³¤½Ñ§Õߺʹ´ÐÂÍŶӷ¢Õ¹¼Æ»®¡±ÈëÑ¡ÍŶÓÕÐÊÕ ²ÄÁÏ£¬»¯Ñ§Ó뻯¹¤²©Ê¿Ñо¿Éú
+1/7
Çൺ¿Æ¼¼´óѧ¿É³ÖÐø¸ß·Ö×ÓÍÅ¶Ó ¿¼ÑÐÕÐÉú
+1/7
¡¾µÚÈýÂÖÕÐÉú¡¿°Ä¿Æ´ó³ÏÕÐ2026ÇïÈ«½±²©Ê¿Ñо¿Éú£¨ÄÉÃ×ҽѧ/ÉúÎï²ÄÁÏ£¬3ÔÂ31ºÅ½ØÖ¹£©
+1/7
Ò׶ȲãÁ÷ÖÊÁ¿Á÷Á¿¿ØÖÆÆ÷ÔÚÆøÒºÁ½ÏàÑ»·Á÷¶¯ÊµÑ鯸Ì嶨Á¿×¢ÒºÖеÄÓ¦ÓÃÓëÓÅÊÆ
+1/4
º£ÄÏÒ½¿Æ´óѧ±Ïºé¿½ÌÊÚ¿ÎÌâ×éÕÐÊÕ2026¼¶Ë¶Ê¿Ñо¿Éúµ÷¼Á²¡ÔÉúÎïѧרҵ
+1/4
MTI 380µ÷¼Á
+1/3
ÉîÛÚ´óѧ²ÌÐ˿ƿÎÌâ×鲩ʿºó¼°Ñо¿ÖúÀíÕÐÆ¸
+1/2
±±¾©´óѧ»·¾³Ñ§ÔºÕÅ×Ó˧Ñо¿Ô±ÕÐÊÕ¿ÆÑÐÖúÀí
+1/1
yinjuanchen
Ìú¸Ëľ³æ (ÖøÃûдÊÖ)
- ·ÒëEPI: 39
- Ó¦Öú: 1 (Ó×¶ùÔ°)
- ½ð±Ò: 5909.8
- Ìû×Ó: 2881
- ÔÚÏß: 434.7Сʱ
- ³æºÅ: 961438
2Â¥2011-03-08 11:21:46
yinjuanchen
Ìú¸Ëľ³æ (ÖøÃûдÊÖ)
- ·ÒëEPI: 39
- Ó¦Öú: 1 (Ó×¶ùÔ°)
- ½ð±Ò: 5909.8
- Ìû×Ó: 2881
- ÔÚÏß: 434.7Сʱ
- ³æºÅ: 961438
hmilywq(½ð±Ò+5): 2011-03-09 09:07:02
|
ÔÚÏàͬµÄ·ÖÀëÌõ¼þ϶¼¼ì²âµ½Á˶þ¼×°·ËÄ»·ËغÍÀû¸£Æ½¡£É«Æ×Á÷¶¯Ïà×é³ÉΪ60%µÄÁ×Ëá¶þÇâ¼ØºÍ40%µÄÒÒëæ£¬²¢ÓÃÁÚ±½»ÇËáµ÷½ÚpHÖµÔÚ3.25×óÓÒ¡£¸ßЧҺÏàÉ«Æ×Ôڵȶȷ´ÏàÌõ¼þÏÂÔËÐУ¬ÆøÁ÷ËÙ¶ÈΪ1ml/min.¼ì²â²¨³¤Îª339nm¡£¶þ¼×°·ËÄ»·ËØÏ´Ìá1.5min,Àû¸£Æ½Ï´Ìá13min.ʵÑé¹ý³ÌÖУ¬Ïò¿Õµ¼¹ÜÖÐÌí¼Ó1cmÒÑÖªÁ¿µÄ¿¹ÉúËØ£¬²¢ÔÚÉÏÊöÌõ¼þÏ·ÖÀë¡£¿¹ÉúËØµÄ»ØÊÕÁ¿´óÓÚ90%¡£ ´Ó»æÖƵıê×¼ÇúÏßÉÏ¿ÉÖª£¬¿¹ÉúËØÁ¿¼ì²âµÄ¾«È·¶È´óÓÚ85%¡£ ps£º²»ÊÇÕâ¸ö·½ÏòµÄ£¬ÒëµÃ²»ºÃ£¬¾´Çë¼ûÁ¡£Ï£Íûͨ¹ý·Ò룬Ìá¸ß×Ô¼ºµÄÀí½âˮƽ£¬ÆÚ´ý¸ßÊÖÖ¸µã¡£ |
3Â¥2011-03-08 12:30:25
Mally89
Ìú¸Ëľ³æ (Ö°Òµ×÷¼Ò)
- ·ÒëEPI: 79
- Ó¦Öú: 7 (Ó×¶ùÔ°)
- ¹ó±ö: 1.257
- ½ð±Ò: 5347.3
- Ìû×Ó: 3712
- ÔÚÏß: 1225.5Сʱ
- ³æºÅ: 1150928
hmilywq(½ð±Ò+7, ·ÒëEPI+1): 2011-03-09 09:06:45
hmilywq(½ð±Ò+2): 2011-03-09 09:07:17
hmilywq(½ð±Ò+2): 2011-03-09 09:07:17
|
Both minocycline and rifampin were detected under the same separation conditions.ÔÚÏàͬµÄ·ÖÀëÌõ¼þÏÂÎÒÃÇͬʱ·¢ÏÖÁËÃ×ŵ»·ËغÍÀû¸£Æ½¡£ The mobile phase consists of KH2PO4(60%)and acetonitrile(40%)with the final pH adjutsed to ~3.25 using 85% O-phosphoric acid. Õâ¸öÁ÷¶¯ÏàÓÉKH2PO4(60%)ºÍͨ¹ý85%µÄÑõºÏÁ×ËáÏ¡Ê͵½×îÖÕPHΪ3.25µÄÒÒëæ£¨40%£©×é³É¡£ The HPLC system was run under an isocratic reversed-phase condition with a flow rate of 1mL/min.Detection was done at a wavelength of 339 nm. Õâ¸ö¸ßѹҺÌåÉ«²ã·¨ÏµÍ³ÊÇÓÃ1mL/minµÄÁ÷ËÙÔڵȶȷ´Ïà״̬µÄÌõ¼þÏÂÔËÐУ¬²¢ÔÚ339nmµÄ²¨³¤Ï½øÐмì²â¡£ Minocycline was eluted at 1.5 min,and rifampin was detected at 13 min. ÆäÖÐÃÀÂúÃ¹ËØÏ´ÍÑʱ¼äΪ1.5·ÖÖÓ£¬Àû¸£Æ½¼ì²âʱ¼äΪ13·ÖÖÓ¡£ In pilot trials,known amounts of antibiotics were added to 1-cm segments of uncoated catheters and extracted as outlined above. ÔÚÊÔµãÊÔÑéÖУ¬½«ÒÑÖªÁ¿µÃ¿¹ÉúËØ¼ÓÈ뵽Ϳ²ãµ¼¹ÜµÄ1ÀåÃ×´¦²¢ÈçÉÏÎÄËùÊöµÄ·½Ê½ÌáÈ¡³ö¡£ More than 90% of both antibiotics were recovered. After construction of standard curves,antibiotic cintrols were measured with a consistent accuracy of >85%. ÆäÖг¬¹ý90£¥µÄ¿¹ÉúËØ¶¼Äܹ»±»»ØÊÕ¡£ÔÚÐγɱê×¼ÇúÏߺ󣬲ⶨ¿¹ÉúËØµÄµ÷¿ØÄÜÁ¦ºÍÒÑÖªµÄ´ïµ½ÁË85%ÒÔÉϵÄÒ»ÖÂÐÔ¡£ àÅ£¬ÎÒ·Ö¿ª¸øÄã½âÊÍÁËһϡ£ÆäÖÐÊÇÓм¸¸öרҵ´ÊµÄƴд²»ÊÇÌ«¶Ô£¬ÎÒ¸ø¸ÄÁ˹ýÀ´£¬Ä㿴һϣ¬¶ÔÒ»¶ÔÊDz»ÊÇÄãËùÐèÒªµÄ¡£ |
4Â¥2011-03-08 12:44:54













»Ø¸´´ËÂ¥