| 查看: 1078 | 回复: 6 | |||
[交流]
翻译美国药典拉米夫定
|
|
Identification— A: Infrared Absorption 197M. B: The retention time of the major peak in the chromatogram of the Test solution corresponds to that in the chromatogram of the Resolution solution, as obtained in the test for Limit of lamivudine enantiomer. Light absorption— Its absorptivity (see Spectrophotometry and Light-Scattering 851) at 440 nm, determined in 4-cm cells with a 50 mg per mL solution in water, is not more than 0.0015. Water, Method Ic 921: not more than 0.2%. Limit of lamivudine enantiomer— 0.1 M Ammonium acetate solution— Dissolve about 7.7 g of ammonium acetate in water, and dilute with water to 1000 mL. Mobile phase— Prepare a suitable mixture of 0.1 M Ammonium acetate solution and methanol (95:5), mix, filter, and degas. Resolution solution— Dissolve an accurately weighed quantity of USP Lamivudine Resolution Mixture A RS in water to obtain a solution having a known concentration of about 0.25 mg per mL. Test solution— Transfer about 25 mg of Lamivudine, accurately weighed, to a 100-mL volumetric flask, dissolve in and dilute with water to volume, and mix. Chromatographic system (see Chromatography 621)— The liquid chromatograph is equipped with a 270-nm detector and a 4.6-mm × 25-cm column that contains packing L45. The column temperature is maintained at a constant temperature of between 15 and 30. The flow rate is about 1.0 mL per minute. Chromatograph the Resolution solution, and record the peak responses as directed for Procedure: the resolution, R, between lamivudine and lamivudine enantiomer is not less than 1.5. [note—The relative retention times are about 1.0 for lamivudine and about 1.2 for lamivudine enantiomer.] Procedure— Inject a volume (about 10 µL) of the Test solution into the chromatograph, record the chromatogram, and measure the responses for the major peaks. Calculate the percentage of lamivudine enantiomer in the portion of Lamivudine taken by the formula: 100[rU /(rU + rS)] in which rU and rS are the peak responses of lamivudine enantiomer and lamivudine, respectively: not more than 0.3% is found. Limit of residual solvents— Internal standard solution— Transfer about 1 mL of 2-pentanone, accurately measured, to a 100-mL volumetric flask, dilute with a mixture of dimethyl sulfoxide and water (1:1) to volume, and mix. Standard solution— Transfer 10 mL of Internal standard solution to a 100-mL volumetric flask. To the same flask add an accurately measured quantity of about 100 µL of each of the following: dehydrated alcohol, isopropyl acetate, methanol, and triethylamine. Dilute with a mixture of dimethyl sulfoxide and water (1:1) to volume, and mix. Test solution— Transfer about 5 g of Lamivudine, accurately weighed, to a 100-mL volumetric flask, add 10 mL of Internal standard solution, dilute with a mixture of dimethyl sulfoxide and water (1:1) to volume, and mix. Chromatographic system (see Chromatography 621)— The gas chromatograph is equipped with a split injection port, a flame-ionization detector, and a 0.53-mm × 50-m column coated with a 5-µm film of phase G1. The carrier gas is hydrogen at a pressure of 5 psig. The split flow rate is about 320 mL per minute. The chromatograph is programmed as follows. Initially the temperature of the column is maintained at 70 for 3 minutes, then increased at a rate of 30 per minute to 200, and maintained at that temperature for 6.5 minutes. The injection port temperature is maintained at 150 and the detector temperature is maintained at 250. Procedure— Separately inject equal volumes (about 0.5 µL) of the Standard solution and the Test solution into the chromatograph, record the chromatograms, and measure the peak areas. Calculate the percentage of each residual solvent in the portion of Lamivudine taken by the formula: 10(C/W)(RU / RS) in which C is the concentration, in mg per mL, of the respective analyte in the Standard solution; W is the weight, in g, of Lamivudine taken; and RU and RS are the peak response ratios of the respective analyte to the internal standard obtained from the Test solution and the Standard solution, respectively: not more than 0.2% of alcohol is found; not more than 0.2% of isopropyl acetate is found; not more than 0.1% of methanol is found; not more than 0.1% of triethylamine is found; and not more than 0.3% of total residual solvents is found. Chromatographic purity— 0.025 M Ammonium acetate solution, Mobile phase, System suitability solution, and Chromatographic system— Proceed as directed in the Assay. Salicylic acid solution— Dissolve an accurately weighed quantity of salicylic acid in Mobile phase, and dilute quantitatively, and stepwise if necessary, with Mobile phase to obtain a solution having a concentration of about 0.625 µg per mL. Standard solution— Use the Standard preparation, prepared as directed in the Assay. Test solution— Use the Assay preparation. Procedure— Separately inject equal volumes (about 10 µL) of Salicylic acid solution and the Test solution into the chromatograph, record the chromatograms, and measure all the peak responses. Calculate the percentage of salicylic acid in the portion of Lamivudine taken by the formula: (10C/W)(rU / rS) in which C is the concentration, in µg per mL, of salicylic acid in the Salicylic acid solution; W is the weight, in mg, of Lamivudine taken for the Test solution; and rU and rS are the salicylic acid peak responses obtained from the Test solution and the Salicylic acid solution, respectively. Calculate the percentage of other individual impurities in the portion of Lamivudine taken by the formula: 100(ri / rs) in which ri is the peak response for each impurity other than salicylic acid obtained from the Test solution; and rs is the sum of the responses for all the peaks: not more than 0.3% for any peak at a relative retention time of about 0.4 is found; not more than 0.2% for any peak at a relative retention time of about 0.9 is found; not more than 0.1% of salicylic acid is found; not more than 0.1% of any other individual impurity is found; and not more than 0.6% of total impurities is found. Assay— 0.025 M Ammonium acetate solution— Transfer about 1.9 g of ammonium acetate to a 1000-mL volumetric flask, dissolve in about 900 mL of water, adjust with acetic acid to a pH of 3.8 ± 0.2, dilute with water to volume, and mix. Mobile phase— Prepare a filtered and degassed mixture of 0.025 M Ammonium acetate solution and methanol (95:5). Make adjustments if necessary (see System Suitability under Chromatography 621). System suitability solution— Dissolve an accurately weighed quantity of USP Lamivudine Resolution Mixture B RS in Mobile phase to obtain a solution having a known concentration of about 0.25 mg per mL. Standard preparation— Dissolve an accurately weighed quantity of USP Lamivudine RS in Mobile phase, and dilute quantitatively, and stepwise if necessary, with Mobile phase to obtain a solution having a known concentration of about 0.25 mg per mL. Assay preparation— Transfer about 25 mg of Lamivudine, accurately weighed, to a 100-mL volumetric flask, dissolve in and dilute with Mobile phase to volume, and mix. Chromatographic system (see Chromatography 621)— The liquid chromatograph is equipped with a 277-nm detector and a 4.6-mm × 25-cm column that contains packing L1. The flow rate is about 1.0 mL per minute. The column temperature is maintained at 35. Chromatograph the System suitability solution, and record the peak responses as directed for Procedure: the resolution, R, between lamivudine and lamivudine diastereomer is not less than 1.5. [note—The relative retention times are about 1.0 for lamivudine and 0.9 for lamivudine diastereomer.] Chromatograph the Standard preparation, and record the peak responses as directed for Procedure: the relative standard deviation for replicate injections is not more than 2.0%. Procedure— Separately inject equal volumes (about 10 µL) of the Standard preparation and the Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the lamivudine peaks. Calculate the quantity, in mg, of C8H11N3O3S in the portion of Lamivudine taken by the formula: 100C(rU / rS) in which C is the concentration, in mg per mL, of USP Lamivudine RS in the Standard preparation; and rU and rS are the peak responses obtained from the Assay preparation and the Standard preparation, respectively. Auxiliary Information— Please check for your question in the FAQs before contacting USP. Topic/Question Contact Expert Committee Monograph Behnam Davani, Ph.D., M.B.A. Senior Scientist 1-301-816-8394 (MDAA05) Monograph Development-Antivirals and Antimicrobials Reference Standards Lili Wang, Technical Services Scientist 1-301-816-8129 |
» 猜你喜欢
广西大学-广州大学招聘博士后 欢迎广大优秀人才!!!
已经有6人回复
两块石头
已经有5人回复
面上没中,邀请各位路过的虫友分析一下分数
已经有8人回复
售SCI一区T0P文章,我:8O.55.1.O.54,科目全,可伽急
已经有7人回复
哈尔滨工业大学韩晓军教授课题组招收2027年硕士推免生及博士研究生
已经有3人回复
找导师
已经有8人回复
国社科又开始会评了,不知道这次命运如何
已经有14人回复
科研人应该花精力去思考如何解决问题,而不是去凝练问题
已经有14人回复
要骂人了,新模版改版就是要淡化问题凝练这种虚的东西,结果有个评委还在说凝练得不够
已经有17人回复
学科评审组评审是指会评吗?
已经有5人回复
» 抢金币啦!回帖就可以得到:
云南大学丁军桥团队2027年博士招生
+1/805
【征稿中!】2026年机械、制造技术与材料国际会议 (MEMTM 2026)
+1/559
招收大湾区大学-哈工深联培博士1名
+2/192
复旦大学国家级青年人才课题组招收2027级博士研究生(微电子方向)
+1/100
南京大学医学院附属鼓楼医院 肿瘤疫苗与纳米医学团队 博士后招聘
+1/87
2027级博士研究生——质谱分析
+5/75
深圳大学刘翼振课题组诚聘博士后(CRISPR分子诊断)
+1/49
电子科技大学李卫课题组招收2027级博士(统计物理学方向)
+1/20
评职称需要,卖发明专利了:D有技术储备需求的设备厂商可联系
+1/18
天津大学浙江研究院2026年第二批招聘公告:高分子等方向特聘青年研究员/博士后
+1/14
首都医科大学附属北京地坛医院欢迎优秀本科生申请免疫学推免硕士/直博生(5年制)
+1/9
【诚聘英才】东南大学“本能行为与生理稳态的神经环路研究”课题组招聘博士后
+1/7
【合作招募】学生筛选、前期沟通与过程协调,可由平台共同承担
+1/6
苦寻-西安交通大学统计学同学
+1/5
浙大城市学院功能材料工程研究中心诚聘海内外英才
+1/5
新加坡国立大学Sibudjing Kawi教授课题组part-time PhD(热催化/等离子体催化方向)
+1/4
深圳大学岩土多场耦合课题组-长期招聘研究生、博士后、专职研究人员
+1/4
【科研诚信】武汉轻工大学何江玲3篇论文:涉嫌抄袭、成组数据重复、制造虚假显著
+1/2
义翘神州推出全长p-Tau217蛋白,助力阿尔茨海默病下一代生物标志物检测开发
+1/2
西安交通大学统计学专业同学冒个泡呗
+1/2
yufu0522(金币+1, 翻译EPI+1): 2010-12-23 23:06:00
ringzhu(翻译EPI-1):发放错误~~~ 2010-12-27 10:55:43
ringzhu(翻译EPI-1):发放错误~~~ 2010-12-27 10:55:43
| 很好很强大。 |
2楼2010-12-23 10:58:06
3楼2010-12-23 23:05:48
4楼2010-12-23 23:07:18
5楼2010-12-28 09:36:21
6楼2010-12-29 20:33:49
7楼2010-12-31 14:06:18










回复此楼