| 查看: 935 | 回复: 6 | |||
[交流]
翻译美国药典拉米夫定
|
|
Identification— A: Infrared Absorption 197M. B: The retention time of the major peak in the chromatogram of the Test solution corresponds to that in the chromatogram of the Resolution solution, as obtained in the test for Limit of lamivudine enantiomer. Light absorption— Its absorptivity (see Spectrophotometry and Light-Scattering 851) at 440 nm, determined in 4-cm cells with a 50 mg per mL solution in water, is not more than 0.0015. Water, Method Ic 921: not more than 0.2%. Limit of lamivudine enantiomer— 0.1 M Ammonium acetate solution— Dissolve about 7.7 g of ammonium acetate in water, and dilute with water to 1000 mL. Mobile phase— Prepare a suitable mixture of 0.1 M Ammonium acetate solution and methanol (95:5), mix, filter, and degas. Resolution solution— Dissolve an accurately weighed quantity of USP Lamivudine Resolution Mixture A RS in water to obtain a solution having a known concentration of about 0.25 mg per mL. Test solution— Transfer about 25 mg of Lamivudine, accurately weighed, to a 100-mL volumetric flask, dissolve in and dilute with water to volume, and mix. Chromatographic system (see Chromatography 621)— The liquid chromatograph is equipped with a 270-nm detector and a 4.6-mm × 25-cm column that contains packing L45. The column temperature is maintained at a constant temperature of between 15 and 30. The flow rate is about 1.0 mL per minute. Chromatograph the Resolution solution, and record the peak responses as directed for Procedure: the resolution, R, between lamivudine and lamivudine enantiomer is not less than 1.5. [note—The relative retention times are about 1.0 for lamivudine and about 1.2 for lamivudine enantiomer.] Procedure— Inject a volume (about 10 µL) of the Test solution into the chromatograph, record the chromatogram, and measure the responses for the major peaks. Calculate the percentage of lamivudine enantiomer in the portion of Lamivudine taken by the formula: 100[rU /(rU + rS)] in which rU and rS are the peak responses of lamivudine enantiomer and lamivudine, respectively: not more than 0.3% is found. Limit of residual solvents— Internal standard solution— Transfer about 1 mL of 2-pentanone, accurately measured, to a 100-mL volumetric flask, dilute with a mixture of dimethyl sulfoxide and water (1:1) to volume, and mix. Standard solution— Transfer 10 mL of Internal standard solution to a 100-mL volumetric flask. To the same flask add an accurately measured quantity of about 100 µL of each of the following: dehydrated alcohol, isopropyl acetate, methanol, and triethylamine. Dilute with a mixture of dimethyl sulfoxide and water (1:1) to volume, and mix. Test solution— Transfer about 5 g of Lamivudine, accurately weighed, to a 100-mL volumetric flask, add 10 mL of Internal standard solution, dilute with a mixture of dimethyl sulfoxide and water (1:1) to volume, and mix. Chromatographic system (see Chromatography 621)— The gas chromatograph is equipped with a split injection port, a flame-ionization detector, and a 0.53-mm × 50-m column coated with a 5-µm film of phase G1. The carrier gas is hydrogen at a pressure of 5 psig. The split flow rate is about 320 mL per minute. The chromatograph is programmed as follows. Initially the temperature of the column is maintained at 70 for 3 minutes, then increased at a rate of 30 per minute to 200, and maintained at that temperature for 6.5 minutes. The injection port temperature is maintained at 150 and the detector temperature is maintained at 250. Procedure— Separately inject equal volumes (about 0.5 µL) of the Standard solution and the Test solution into the chromatograph, record the chromatograms, and measure the peak areas. Calculate the percentage of each residual solvent in the portion of Lamivudine taken by the formula: 10(C/W)(RU / RS) in which C is the concentration, in mg per mL, of the respective analyte in the Standard solution; W is the weight, in g, of Lamivudine taken; and RU and RS are the peak response ratios of the respective analyte to the internal standard obtained from the Test solution and the Standard solution, respectively: not more than 0.2% of alcohol is found; not more than 0.2% of isopropyl acetate is found; not more than 0.1% of methanol is found; not more than 0.1% of triethylamine is found; and not more than 0.3% of total residual solvents is found. Chromatographic purity— 0.025 M Ammonium acetate solution, Mobile phase, System suitability solution, and Chromatographic system— Proceed as directed in the Assay. Salicylic acid solution— Dissolve an accurately weighed quantity of salicylic acid in Mobile phase, and dilute quantitatively, and stepwise if necessary, with Mobile phase to obtain a solution having a concentration of about 0.625 µg per mL. Standard solution— Use the Standard preparation, prepared as directed in the Assay. Test solution— Use the Assay preparation. Procedure— Separately inject equal volumes (about 10 µL) of Salicylic acid solution and the Test solution into the chromatograph, record the chromatograms, and measure all the peak responses. Calculate the percentage of salicylic acid in the portion of Lamivudine taken by the formula: (10C/W)(rU / rS) in which C is the concentration, in µg per mL, of salicylic acid in the Salicylic acid solution; W is the weight, in mg, of Lamivudine taken for the Test solution; and rU and rS are the salicylic acid peak responses obtained from the Test solution and the Salicylic acid solution, respectively. Calculate the percentage of other individual impurities in the portion of Lamivudine taken by the formula: 100(ri / rs) in which ri is the peak response for each impurity other than salicylic acid obtained from the Test solution; and rs is the sum of the responses for all the peaks: not more than 0.3% for any peak at a relative retention time of about 0.4 is found; not more than 0.2% for any peak at a relative retention time of about 0.9 is found; not more than 0.1% of salicylic acid is found; not more than 0.1% of any other individual impurity is found; and not more than 0.6% of total impurities is found. Assay— 0.025 M Ammonium acetate solution— Transfer about 1.9 g of ammonium acetate to a 1000-mL volumetric flask, dissolve in about 900 mL of water, adjust with acetic acid to a pH of 3.8 ± 0.2, dilute with water to volume, and mix. Mobile phase— Prepare a filtered and degassed mixture of 0.025 M Ammonium acetate solution and methanol (95:5). Make adjustments if necessary (see System Suitability under Chromatography 621). System suitability solution— Dissolve an accurately weighed quantity of USP Lamivudine Resolution Mixture B RS in Mobile phase to obtain a solution having a known concentration of about 0.25 mg per mL. Standard preparation— Dissolve an accurately weighed quantity of USP Lamivudine RS in Mobile phase, and dilute quantitatively, and stepwise if necessary, with Mobile phase to obtain a solution having a known concentration of about 0.25 mg per mL. Assay preparation— Transfer about 25 mg of Lamivudine, accurately weighed, to a 100-mL volumetric flask, dissolve in and dilute with Mobile phase to volume, and mix. Chromatographic system (see Chromatography 621)— The liquid chromatograph is equipped with a 277-nm detector and a 4.6-mm × 25-cm column that contains packing L1. The flow rate is about 1.0 mL per minute. The column temperature is maintained at 35. Chromatograph the System suitability solution, and record the peak responses as directed for Procedure: the resolution, R, between lamivudine and lamivudine diastereomer is not less than 1.5. [note—The relative retention times are about 1.0 for lamivudine and 0.9 for lamivudine diastereomer.] Chromatograph the Standard preparation, and record the peak responses as directed for Procedure: the relative standard deviation for replicate injections is not more than 2.0%. Procedure— Separately inject equal volumes (about 10 µL) of the Standard preparation and the Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the lamivudine peaks. Calculate the quantity, in mg, of C8H11N3O3S in the portion of Lamivudine taken by the formula: 100C(rU / rS) in which C is the concentration, in mg per mL, of USP Lamivudine RS in the Standard preparation; and rU and rS are the peak responses obtained from the Assay preparation and the Standard preparation, respectively. Auxiliary Information— Please check for your question in the FAQs before contacting USP. Topic/Question Contact Expert Committee Monograph Behnam Davani, Ph.D., M.B.A. Senior Scientist 1-301-816-8394 (MDAA05) Monograph Development-Antivirals and Antimicrobials Reference Standards Lili Wang, Technical Services Scientist 1-301-816-8129 |
» 猜你喜欢
求碳排放博导;方向是LCA、生命周期可持续发展以及碳排放
已经有5人回复
26年博士申请自荐-电催化
已经有7人回复
2026年博士申请求捞
已经有3人回复
2026博士或科研助理转27年博士
已经有6人回复
国自科送审了吗
已经有11人回复
博士招生
已经有5人回复
夜,静悄悄的
已经有8人回复
研究生做的很差,你们会让毕业吗?
已经有6人回复
26年申博自荐-计算机视觉
已经有4人回复
» 抢金币啦!回帖就可以得到:
坐标南京,诚租女友
+5/9316
2026年江西师范大学药学院陈芬儿院士课题组招收智能药学博士生
+2/114
2026年江西师范大学人文地理与低碳经济方向拟招收1名“申请入学制”学术博士研究生
+2/108
有能报销版面费的老师合作发表SCI开源期刊吗?
+1/87
东北林业大学化学专业招申请考核博士生
+1/87
河南师范大学水产学院博士研究生招生
+1/85
招聘科研助理
+1/79
湖南大学材料学院招收2026年秋季入学学术博士生1名:锂电池方向
+1/39
诚征女友,坐标西安
+1/20
南京邮电大学李巍教授招收2026博士生(5月12日前有效)
+1/18
中国农业大学资源与环境学院 - 招聘杰出人才、青年研究员、优秀人才和博士后
+1/13
申请账号解封
+1/10
天津医科大学王霆教授团队,诚招2026级申请考核制博士生1名
+1/8
注册小木虫周年大礼包领取不了
+1/5
港科大广州 - 量子计算全额奖学金博士招聘(申请制,2026和2027均有名额)
+1/4
成都中医药大学药学院 谢恬教授招收2026级药物化学,有机合成方向的博士生
+1/4
中南大学地信院潘老师团队招收航天摄影测量与三维计算机视觉方向2026年入学博士生
+1/3
香港科技大学 招生 全奖博士 -- 机器人/电子/材料
+1/3
【限时补录】澳科大2026年秋季入学药剂学硕士研究生1-2名
+1/2
天津医科大学基础医学院基础医学院2026级博士招生
+1/2
yufu0522(金币+1, 翻译EPI+1): 2010-12-23 23:06:00
ringzhu(翻译EPI-1):发放错误~~~ 2010-12-27 10:55:43
ringzhu(翻译EPI-1):发放错误~~~ 2010-12-27 10:55:43
| 很好很强大。 |
2楼2010-12-23 10:58:06
3楼2010-12-23 23:05:48
4楼2010-12-23 23:07:18
5楼2010-12-28 09:36:21
6楼2010-12-29 20:33:49
7楼2010-12-31 14:06:18












回复此楼