| ²é¿´: 1312 | »Ø¸´: 4 | |||
| µ±Ç°Ö»ÏÔʾÂú×ãÖ¸¶¨Ìõ¼þµÄ»ØÌû£¬µã»÷ÕâÀï²é¿´±¾»°ÌâµÄËùÓлØÌû | |||
songzi136½ð³æ (ÕýʽдÊÖ)
|
[½»Á÷]
¡¾ÇóÖú¡¿ÇëÎÊʲôÊÇÄâËÆ±ê׼Ʒ (Surrogate Standard)£¿
|
||
|
ÇëÎÊʲôÊÇÄâËÆ±ê׼Ʒ (Surrogate Standard)£¿ ÔÚ²âCOX-2µÄIC50ʱ£¬»¨ÉúËÄÏ©ËáµÄ´úл²úÎïPGE2£¬µ«Í¬Ê±ÓÖÓÃÁË[d4]-PGE2×÷ΪSurrogate Standard£¬²»Ã÷°×£¿ |
» ²ÂÄãϲ»¶
308Çóµ÷¼Á
ÒѾÓÐ20È˻ظ´
ÖпÆÔº×Ü·Ö315Çóµ÷¼Á
ÒѾÓÐ3È˻ظ´
Çóµ÷¼Á ²ÄÁÏÓ빤³Ì 324·Ö ר˶
ÒѾÓÐ3È˻ظ´
»¯Ñ§¹¤³ÌÓë¼¼Êõ324µ÷¼Á
ÒѾÓÐ15È˻ظ´
Ò»Ö¾Ô¸¿ó´ó£¬²ÄÁϹ¤³Ìר˶314·Ö£¬0856¿Éµ÷¶¼¿ÉÒÔ
ÒѾÓÐ12È˻ظ´
»·Ñõ¹à·â½º ¿¹³Á¼Á
ÒѾÓÐ4È˻ظ´
268·Ö085602»¯Ñ§¹¤³Ìµ÷¼Á
ÒѾÓÐ22È˻ظ´
¿¼Ñе÷¼Á
ÒѾÓÐ18È˻ظ´
»¹Óл¯¹¤¶þÂÖµ÷¼ÁµÄѧУÂð
ÒѾÓÐ39È˻ظ´
277 ÊýÒ»104£¬Ñ§Ë¶£¬Çóµ÷¼Á
ÒѾÓÐ8È˻ظ´
» ±¾Ö÷ÌâÏà¹Ø¼ÛÖµÌùÍÆ¼ö£¬¶ÔÄúͬÑùÓаïÖú:
¡¾ÇóÖú/½»Á÷¡¿ÄâÄϽ汣ÎÀϸ°ûÔÉúÖÊÌåRNAÌáÈ¡µçӾͼ£¬³öÏÖ·´ÏòÃÖÉ¢£¿
ÒѾÓÐ6È˻ظ´
¡¾ÇóÖú¡¿¼¸¸ö¶¯Á¦Ñ§µÄ»ù±¾¸ÅÄî¹ØÏµ
ÒѾÓÐ0È˻ظ´
¡¾ÇóÖú¡¿¹ØÓÚÄâºÏµÃµ½Ì嵯ÐÔÄ£Á¿&×ÔÐý¼«»¯&LDA+UµÈÎÊÌ⣬Íû´ó¼ÒÖ¸µãÖ¸µã
ÒѾÓÐ4È˻ظ´
¡¾ÇóÖú¡¿ÇóÖú£º¸ºÖ¸Êý·Ö²¼£¬¶ÔÊýÕý̬·Ö²¼£¬Íþ²¼¶û·Ö²¼
ÒѾÓÐ2È˻ظ´
¡¾ÇóÖú/½»Á÷¡¿ÈçºÎÈ·¶¨Î´Öª»ùÒò±àÂë°±»ùËá¡«
ÒѾÓÐ8È˻ظ´
¡¾ÇóÖú¡¿Óà design expert ½øÐÐBox-Behnken Design ʵÑé
ÒѾÓÐ1È˻ظ´
¡¾ÇóÖú/½»Á÷¡¿ÇóÖú£ºÅ©¸Ë¾úÇÖȾÄâÄϽ滨ÐòµÄÅçÎíת»¯·½·¨
ÒѾÓÐ6È˻ظ´
¡¾ÇóÖú/½»Á÷¡¿¹ØÓÚÄâÄϽæÓªÑøÒºµÄÎÊÌâ
ÒѾÓÐ3È˻ظ´
¡¾ÆäËû¡¿originʹÓý̳ÌÌù´ó¼¯ºÏ
ÒѾÓÐ30È˻ظ´
¡¾ÇóÖú/½»Á÷¡¿Çë½ÌÇàùÃû³ÆµÄÎÊÌâ~лл
ÒѾÓÐ3È˻ظ´
¡¾ÇóÖú/½»Á÷¡¿Anti-phospho-p42/44 ¿¹ÌåʹÓÃÇóÖú
ÒѾÓÐ6È˻ظ´
ÖñÐùÊéͯ
ÖÁ×ðľ³æ (Ö°Òµ×÷¼Ò)
Ê×ϯħ·¨Ê¦
- Ó¦Öú: 6 (Ó×¶ùÔ°)
- ½ð±Ò: 11275
- É¢½ð: 169
- ºì»¨: 6
- ɳ·¢: 4
- Ìû×Ó: 3320
- ÔÚÏß: 241.8Сʱ
- ³æºÅ: 565213
- ×¢²á: 2008-05-28
- ÐÔ±ð: GG
- רҵ: É«Æ×·ÖÎö
songzi136(½ð±Ò+16):¶®ÁËһЩ£¬µ«ÓÐʲôÓû¹ÊÇÓеãºýÍ¿ 2010-11-06 21:30:59
songzi136(½ð±Ò+10): 2010-11-23 14:55:54
songzi136(½ð±Ò+10): 2010-11-23 14:55:54
|
A surrogate standard is a compound that has properties similar to the target analyte(s) that a particular analytical method is designed to identify and measure. The surrogate compound is not expected to be in an environmental field sample and should not interfere with the identification or quantification of the target analytes. By demonstrating that the surrogate compound can be recovered from the sample matrix with reasonable efficiency, the surrogate standard performs a quality control function on the suitability of the analytical method for the intended analyses and on the ability of the laboratory to execute that method with reasonable proficiency. If a surrogate compound is not recovered, an analyte of concern also may not be recovered. Õâ¸ö½âÊ͵ĺÜÏêϸÁ˰ɡ£¹þ¹þ¡¡ |
4Â¥2010-11-05 23:29:43
kitaro
½ð³æ (ÕýʽдÊÖ)
- Ó¦Öú: 41 (СѧÉú)
- ½ð±Ò: 7106.4
- É¢½ð: 5
- Ìû×Ó: 911
- ÔÚÏß: 254.8Сʱ
- ³æºÅ: 565370
- ×¢²á: 2008-05-28
- רҵ: ¸ß·Ö×Ӻϳɻ¯Ñ§
2Â¥2010-11-05 14:13:46
happyjoys
ľ³æ (Ö°Òµ×÷¼Ò)
- Ó¦Öú: 223 (´óѧÉú)
- ½ð±Ò: 3757.1
- É¢½ð: 21
- ºì»¨: 6
- Ìû×Ó: 3884
- ÔÚÏß: 197.7Сʱ
- ³æºÅ: 872702
- ×¢²á: 2009-10-15
- ÐÔ±ð: MM
- רҵ: ¹âÆ×·ÖÎö

3Â¥2010-11-05 21:12:15
ÖñÐùÊéͯ
ÖÁ×ðľ³æ (Ö°Òµ×÷¼Ò)
Ê×ϯħ·¨Ê¦
- Ó¦Öú: 6 (Ó×¶ùÔ°)
- ½ð±Ò: 11275
- É¢½ð: 169
- ºì»¨: 6
- ɳ·¢: 4
- Ìû×Ó: 3320
- ÔÚÏß: 241.8Сʱ
- ³æºÅ: 565213
- ×¢²á: 2008-05-28
- ÐÔ±ð: GG
- רҵ: É«Æ×·ÖÎö
5Â¥2010-11-07 10:42:30













»Ø¸´´ËÂ¥