TPR和TPD分别是表征什么的
|
|||
|
谁能告诉我一下TPR和TPD分别是表征什么的,现在只知道指的是程序升温还原和程序升温脱附,哪位能细致地解释一下啊,感激不尽! 顺便问一下,具体的表征装置是什么样的。[/size] [ Last edited by yutian.35 on 2008-4-24 at 08:11 ] |
» 猜你喜欢
材料/化学相关专业2026级学术/专业型硕士研究生
已经有19人回复
求催化作用基础第三版 (甄开吉) 课件
已经有3人回复
物理化学论文润色/翻译怎么收费?
已经有104人回复
26年材料/化学相关专业博士研究生招生 温州大学化学与材料工程学院(26年秋季入学)
已经有0人回复
求助电催化剂制备,怎么在碳布表面生长PdCo合金
已经有0人回复
求助电催化剂制备,怎么在碳布表面生长PdCo合金
已经有0人回复
304求调剂
已经有3人回复
上海华东理工大学机械与动力工程学院先进材料与制造研究组招聘公告
已经有0人回复
304求调剂
已经有3人回复
ANSYS 静态结构 多线性随动硬化 应变值怎么计算
已经有1人回复
ElectroWang
铜虫 (小有名气)
- 应助: 0 (幼儿园)
- 金币: 609.4
- 散金: 6
- 帖子: 156
- 在线: 64.1小时
- 虫号: 307253
- 注册: 2006-12-16
- 专业: 常微分方程与动力系统
★ ★
nxl5096224(金币+2,VIP+0):多谢关注!
nxl5096224(金币+2,VIP+0):多谢关注!
|
Thermal desorption spectroscopy Thermal desorption spectroscopy (TDS), also known as temperature programmed desorption (TPD) is the method of observing desorbed molecules from a surface when the surface temperature is increased. Many researchers prefer the name TPD because it is not a spectroscopic method. When molecules comes in contact with a surface, they adsorb onto it, minimizing their energy by forming a chemical bond with the surface. The binding energy varies with the combination of the adsorbate and surface. If the surface is heated, at one point, the energy transferred to the adsorbed species will cause it to desorb. The temperature at which this happens is known as the desorption temperature. Thus TDS shows information on the binding energy. Since TDS observes the mass of desorped molecules, it shows what molecules are adsorbed on the surface. Moreover, TDS recognizes the different adsorption conditions of the same molecule from the differences between the desorption temperatures of molecules desorping different sites at the surface, e.g. terrasses vs steps. TDS also obtains the amounts of adsorbed molecules on the surface from the intensity of the peaks of the TDS spectrum, and the total amount of adsorped species is shown by the integral of the spectrum. To measure TDS, one needs a mass spectrometer, such as a quadrupole mass spectrometer or a time-of-flight (TOF) mass spectrometer, under ultrahigh vacuum (UHV) conditions. The amount of adsorbed molecules is counted by increasing the temperature at a heating rate of typically 2K/s-10 K/s. Several masses are simultaneously counted by the mass spectrometer, and the intensity of each mass as a function of temperature is obtained as a TDS spectrum. The heating procedure is often controlled by a computer or a Eurotherm using a PID algorithm. Quantitative Intrepetation of TDS data This is usually done using the "Redhead" method[1], assuming the exponential prefactor and the desorption energy to be independent of the surface coverage. ^ Redhead, P. A. "Thermal desorption of gases" Vacuum 12 (1962) p.203-211 |
7楼2008-04-10 17:48:36
yhjiangshiyu
木虫 (正式写手)
- 应助: 0 (幼儿园)
- 金币: 15680.8
- 帖子: 840
- 在线: 32.5小时
- 虫号: 307492
- 注册: 2006-12-16
- 性别: GG
- 专业: 理论和计算化学

2楼2008-04-08 15:49:13
3楼2008-04-08 16:31:52
liu5288kangkai
木虫 (著名写手)
逍遥忍者
- 应助: 0 (幼儿园)
- 贵宾: 0.15
- 金币: 1833.8
- 红花: 3
- 帖子: 1521
- 在线: 71.3小时
- 虫号: 276474
- 注册: 2006-09-02
- 性别: GG
- 专业: 资源化工
4楼2008-04-09 10:53:04













回复此楼