[求助] 在检测cif 过程中出现了如下A类错误,求帮助 已有1人参与

我用的是咪唑甲基化在CuI中形成的阴阳离子结构
Alert level A
SYMM004_ALERT_1_A  _symmetry_equiv_pos_as_xyz loop is missing.
            The symmetry equivalent positions in xyz.
            The following tests will not be performed.
            CELLZ_01,CHEMW_03,REFLT_03,SYMMG_01,SYMMG_02
ATOM002_ALERT_1_A  _atom_site_label is missing
            Unique label identifying the atom site.
ATOM003_ALERT_1_A  _atom_site_fract_x is missing
            Fractional coordinates of atom site.
ATOM004_ALERT_1_A  _atom_site_fract_y is missing
            Fractional coordinates of atom site.
ATOM005_ALERT_1_A  _atom_site_fract_z is missing
            Fractional coordinates of atom site.
TYPE100_ALERT_1_A  _atom_site_label is not of type char.
TYPE101_ALERT_1_A  _atom_site_fract_x is not of type numb.
TYPE102_ALERT_1_A  _atom_site_fract_y is not of type numb.
TYPE103_ALERT_1_A  _atom_site_fract_z is not of type numb.
ATOM007_ALERT_1_A  _atom_site_aniso_label is missing
            Unique label identifying the atom site.
GEOM001_ALERT_1_A  _geom_bond_atom_site_label_1 is missing
            Label identifying the atom site 1.
GEOM003_ALERT_1_A  _geom_bond_distance is missing
            Distance between atom sites 1 and 2.
GEOM006_ALERT_1_A  _geom_angle_atom_site_label_2 is missing
            Label identifying the atom site 2.
GEOM007_ALERT_1_A  _geom_angle_atom_site_label_3 is missing
            Label identifying the atom site 3.
回复此楼

» 猜你喜欢

» 本主题相关价值贴推荐,对您同样有帮助:

已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

jackdeng

专家顾问 (著名写手)

【答案】应助回帖

★ ★ ★ ★ ★
感谢参与,应助指数 +1
liufang168: 金币+5, 有帮助 2014-07-08 11:43:31
你确定格式cif文件吗?缺了这么多的内容?