[交流] 关于介孔材料吸附CO2的问题

原文:about 100  mg  of  PEI/SBA-15  sample  was  placed  into  a  U-shape  quartz reactor  and  pretreated  at  100◦C  under  helium  flow  (30  ml/min)  for 20  min.  When  the  temperature  was  reduced  to  75◦C,  CO2 sorption was  performed  by  flowing  CO2(10  ml/min)  for  30  min.  Then  the temperature  was  decreased  to  40◦C  under  the  same  CO2 flow.  After that,  the  desorption  experiment  was  executed  by  purging  helium gas  (50  ml/min)  through  the  sorbent  bed  and  ramping  the  temperature  from  40  to  110 ◦C  at  a  rate  of  5◦C/min  and  holding  at  110◦C  for 20  min .The  CO2 uptake  or  sorption  capacity  in  millimole  of  CO2 per gram  of  sorbent  (mmol/g-S)  was  calculated  on  the  basis  of  the  desorbed  CO2 amount  from  the  desorption  curve,  which  was  calibrated by  a  certain  amount  of  CO2.

不明白他的CO2吸附量怎么算的,在这个文章中的实验数据与之前的实验数据有出入。除了SBA-15的结构参数目前还不知道是否一样,其他条件都一样。什么叫calculated  on  the  basis  of  the  desorbed  CO2 amount  from  the  desorption  curve,  which  was  calibrated by  a  certain  amount  of  CO2.???

出处:Wang X, Song C. Temperature-programmed desorption of CO2 from polyethylenimine-loaded SBA-15 as molecular basket sorbents[J]. Catalysis Today, 2012, 194(1): 44-52  (宋春山)