[资源] Pitfalls and Errors of HPLC in Pictures, Third Edition

Pitfalls and Sources of Error
Dr. Veronika R. Meyer
Published Online: 6 FEB 2013
DOI: 10.1002/9783527659104.part2
Copyright © 2013 Wiley-VCH Verlag GmbH & Co. KGaA

Keywords:
sources of error;mobile phase;inadequate purity;incomplete degassing;peaks;quantitative analysis;chemical reaction within the column;flow rate;run time;detection properties
Summary
This part contains sections titled:

Mixing of the Mobile Phase
Mobile Phase pH
Adjustment of Mobile Phase pH
Influence of the Acid Type and Concentration in the Eluent
Water as an Unintentional Additive in the Mobile Phase
Inadequate Purity of Mobile Phase Water
Inadequate Purity of a Mobile Phase Solvent
Inadequate Purity of a Mobile Phase Reagent
Incomplete Degassing
System Peaks and Quantitative Analysis
Sample Preparation with Solid Phase Extraction
Inadequate Stabilization of the Extraction Solvent
Poor Choice of Sample Solvent: Peak Distortion
Poor Choice of Sample Solvent: Tailing
Sample Solvent and Calibration Curve
Impurities in the Sample
Formation of a By-Product in the Sample Solution
Decomposition by the Sample Vial
Artifact Peaks from the Vial Septum
Formation of an Associate in the Sample Solution
Precision and Accuracy with Loop Injection
Injection Technique
Injection of Air
Sample Adsorption in the Loop
Extra-Column Volumes
Dwell Volume
Elution at t0
Classification of C18 Reversed Phases
Different Selectivity of C18 Reversed Phases
Different Batches of Stationary Phase
Chemical Reaction within the Column
Tailing of Phosphate Compounds in the Presence of Steel
Recovery and Peak Shape Problems with Proteins
Double Peaks from Stable Conformers
Influence of Temperature on the Separation
Thermal Non-Equilibrium within the Column
Influence of the Flow Rate on the Separation
Influence of Run Time and Flow Rate on Gradient Separations
UV Spectra and Quantitative Analysis
UV Detection Wavelength
Different Detection Properties of Diastereomers
Fluorescence Quenching by Air
Detector Overload in UV
Detector Overload in ELSD
Influence of the Retention Factor on Peak Height
Influence of the Flow Rate on Peak Area
Leaks in the HPLC Instrument
Impairment of Precision as a Result of Noise
Determination of Peak Area and Height at High Noise
Peak Height Ratios
Incompletely Resolved Peaks
Area Rules for Incompletely Resolved Peaks
Areas of a 1 : 10 Peak Pair
Heights of a 1 : 10 Peak Pair
Quantitative Analysis of a Small Peak
Incompletely Resolved Peaks with Tailing
Integration Threshold and Number of Detected Peaks
Detector Time Constant and Peak Shape
Quantitative Analysis in the 99% Range
Correlation Coefficient of Calibration Curves111

[ Last edited by skdrat on 2013-7-10 at 22:57 ]
回复此楼
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

dryfish

金虫 (著名写手)


★★★★★ 五星级,优秀推荐

goooooooooooooooooooooood
6楼2013-04-23 08:32:23
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

lksweepty

铜虫 (小有名气)


★★★★★ 五星级,优秀推荐

在亚马逊上看到书评找来的,五星鼓励!
14楼2013-07-08 22:45:43
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

xiao5

铜虫 (正式写手)


★★★★★ 五星级,优秀推荐

不能下载么
17楼2014-08-17 11:22:55
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖
简单回复
2013-04-21 23:10   回复  
五星好评  顶一下,感谢分享!
jinyixiao3楼
2013-04-22 00:05   回复  
五星好评  谢谢分享!!!!!!!!!
sjshvdc4楼
2013-04-22 00:13   回复  
五星好评  顶一下,感谢分享!
lp7775楼
2013-04-23 07:42   回复  
三星好评  顶一下,感谢分享!
yxwy2107楼
2013-04-23 08:57   回复  
五星好评  顶一下,感谢分享!
2013-04-23 09:56   回复  
五星好评  顶一下,感谢分享!
2013-04-24 10:24   回复  
五星好评  顶一下,感谢分享!
2013-04-24 12:22   回复  
五星好评  顶一下,感谢分享!
pumcnsy11楼
2013-04-26 21:28   回复  
五星好评  顶一下,感谢分享!
andy56256112楼
2013-05-10 14:52   回复  
五星好评  顶一下,感谢分享!
2013-05-10 15:42   回复  
五星好评  顶一下,感谢分享!
teresagjw15楼
2013-07-08 22:54   回复  
五星好评  顶一下,感谢分享!
redfish16楼
2013-07-09 12:08   回复  
三星好评  顶一下,感谢分享!
相关版块跳转 我要订阅楼主 skdrat 的主题更新
☆ 无星级 ★ 一星级 ★★★ 三星级 ★★★★★ 五星级
普通表情 高级回复 (可上传附件)
信息提示
请填处理意见