| ²é¿´: 464 | »Ø¸´: 2 | |||
[ÇóÖú]
½ø¿ÚÖÊÁ¿±ê×¼ÓëÉ걨ÁÙ´²ÖÊÁ¿±ê×¼²Ý°¸¹ØÓÚÈܳö¶È¼ì²éµÄ¹æ¶¨
|
| ×î½üÔÚ×öÒ»¸ö±¨²úµÄÏîÄ¿£¬ÓÉÓÚÄõ½ÁÙ´²Åú¼þ¾Ý½ñʱ¼ä±È½Ï¾ÃÔ¶£¬ÏÖÔÚ¹¤ÒÕÑéÖ¤´¦·½Èܳö¶È²â¶¨·ûºÏÉ걨ÁÙ´²ÖÊÁ¿±ê×¼²Ý°¸µÄ¹æ¶¨¡£µ«·¢ÏÖ¸ÃÉ걨ÁÙ´²ÖÊÁ¿±ê×¼²Ý°¸Èܳö¶ÈµÄ²â¶¨·½·¨ÔÚתËÙÉϸßÓÚ½ø¿ÚÖÊÁ¿±ê×¼£¬È¡Ñùʱ¼ä³¤ÓÚ½ø¿ÚÖÊÁ¿±ê×¼¡£ÇÒ·¢ÏÖÓÃÉ걨ÁÙ´²ÖÊÁ¿±ê×¼²Ý°¸·½·¨£¬¶ÔÕÕÖÆ¼ÁµÄÈܳöÃ÷ÏÔ¿ìÓÚ×ÔÖÆÖÆ¼ÁµÄ¡£ÎÒÏëÎʵÄÊÇ£¬ÊDz»ÊÇ˵Ã÷´¦·½Òª×ö¸ü¸Ä£¿ÁíÍ⣬ÇëÎÊÈçºÎÀí½â¡°Ò»¶¨Òª²Î¿¼ÖÊÁ¿±ê×¼»ò½ø¿Ú×¢²á±ê×¼£¬µ«²»ÄÜÃÔÐÅ¡±£¿ |
» ÊÕ¼±¾ÌûµÄÌÔÌûר¼ÍƼö
ÌÔÌÔ |
» ²ÂÄãϲ»¶
°ÍÀèÈø¿ËÀ×´óѧÓë¹ú¼ÒÁôѧ»ù½ðίºÏ×÷²©Ê¿Ñо¿ÉúÏîÄ¿-Ö¬ÖÊÄÉÃ×Ò©Îï/ÉúÎï²ÄÁÏ/¶à·ÓµÝËÍ
ÒѾÓÐ10È˻ظ´
½õÖÝÒ½¿Æ´óѧҩÓÃÉúÎï²ÄÁÏ£¨×¨Òµ´úÂë1007Z1£©ÕÐÊÕµ÷¼Á¿¼Éú
ÒѾÓÐ0È˻ظ´
Ò©ÀíѧÂÛÎÄÈóÉ«/·ÒëÔõôÊÕ·Ñ?
ÒѾÓÐ102È˻ظ´
½õÖÝÒ½¿Æ´óѧҩÓÃÉúÎï²ÄÁÏ£¨×¨Òµ´úÂë1007Z1£©ÕÐÊÕµ÷¼Á¿¼Éú
ÒѾÓÐ2È˻ظ´
26É격×Ô¼ö
ÒѾÓÐ12È˻ظ´
SUES&NERCN¿ÎÌâ×é½ÓÊÜ˶ʿÉúµ÷¼Á (ѧ˶1Ãû+ר˶1Ãû)
ÒѾÓÐ0È˻ظ´
SUES&NERCN¿ÎÌâ×é½ÓÊÜ˶ʿÉúµ÷¼Á (ѧ˶1Ãû+ר˶1Ãû)
ÒѾÓÐ0È˻ظ´
¿¼Ñе÷¼Á£º¹ú¼Òµ°°×ÖÊ¿ÆÑ§ÖÐÐÄ£¨¹ú¼ÒÖØµãʵÑéÊÒ£©ºÍ°²»ÕÒ½¿Æ´óѧ»ù´¡Ò½Ñ§ÔºÁªÅà
ÒѾÓÐ4È˻ظ´
SUES&NERCN¿ÎÌâ×é½ÓÊÜ˶ʿÉúµ÷¼Á (ѧ˶1Ãû+ר˶1Ãû)
ÒѾÓÐ0È˻ظ´
»ªÄÏÀí¹¤´óѧ »ù´¡Ò½Ñ§Ñ§Ë¶ºÍÁÙ´²Ò½Ñ§Ñ§Ë¶µ÷¼Á
ÒѾÓÐ11È˻ظ´
catwithdog
гæ (³õÈëÎÄ̳)
- Ó¦Öú: 15 (СѧÉú)
- ½ð±Ò: 103
- É¢½ð: 15
- Ìû×Ó: 34
- ÔÚÏß: 18.6Сʱ
- ³æºÅ: 2077414
- ×¢²á: 2012-10-22
- רҵ: Ò©Îï·ÖÎö
¡¾´ð°¸¡¿Ó¦Öú»ØÌû
¡ï ¡ï ¡ï ¡ï ¡ï
¸Ðл²ÎÓ룬ӦÖúÖ¸Êý +1
´ÓÍ·¿ªÊ¼: ½ð±Ò+5, ¸Ðл²ÎÓë 2012-11-03 08:19:06
¸Ðл²ÎÓ룬ӦÖúÖ¸Êý +1
´ÓÍ·¿ªÊ¼: ½ð±Ò+5, ¸Ðл²ÎÓë 2012-11-03 08:19:06
|
ÇëÎÊÈçºÎÀí½â¡°Ò»¶¨Òª²Î¿¼ÖÊÁ¿±ê×¼»ò½ø¿Ú×¢²á±ê×¼£¬µ«²»ÄÜÃÔÐÅ¡±£¿ For your reference: Ò»¶¨Òª²Î¿¼ÖÊÁ¿±ê×¼»ò½ø¿Ú×¢²á±ê×¼ This is a very helpful in vitro reference for your dissolution testing. If your drug showed the same in vitro dissolution profile by using the same dissolution method, at least you can start to try PK study. Otherwise you need optimize your formulation further. µ«²»ÄÜÃÔÐÅ The most important is your drug human PK data. You need meet BE range. Therefore even your drug showed the same dissolution profile in vitro as brand drug by using ²Î¿¼ÖÊÁ¿±ê×¼»ò½ø¿Ú×¢²á±ê×¼, you may not have the same BE which means your drug also will have possibility to fail. ÇÒ·¢ÏÖÓÃÉ걨ÁÙ´²ÖÊÁ¿±ê×¼²Ý°¸·½·¨£¬¶ÔÕÕÖÆ¼ÁµÄÈܳöÃ÷ÏÔ¿ìÓÚ×ÔÖÆÖÆ¼ÁµÄ¡£ÎÒÏëÎʵÄÊÇ£¬ÊDz»ÊÇ˵Ã÷´¦·½Òª×ö¸ü¸Ä£¿ Most likely you will have different PK profile. If you are working on generic drug, it is better to improve your formulation to get the same dissolution profile as brand. If in this case, for my daily work, I will immediately modify my formulation to save your future time. |
2Â¥2012-11-03 07:48:09
gwmgyp
°æÖ÷ (ÖªÃû×÷¼Ò)
°áש½«
- DRDEPI: 8
- Ó¦Öú: 820 (²©ºó)
- ¹ó±ö: 3.006
- ½ð±Ò: 17161.9
- É¢½ð: 13
- ºì»¨: 67
- ɳ·¢: 1
- Ìû×Ó: 5612
- ÔÚÏß: 944.5Сʱ
- ³æºÅ: 1272275
- ×¢²á: 2011-04-21
- רҵ: Ò©Îï·ÖÎö
- ¹ÜϽ: ÐÂÒ©Ñз¢

3Â¥2012-11-03 08:18:13














»Ø¸´´ËÂ¥