| 查看: 661 | 回复: 4 | |||
| 本帖产生 1 个 翻译EPI ,点击这里进行查看 | |||
| 当前只显示满足指定条件的回帖,点击这里查看本话题的所有回帖 | |||
lty1008200金虫 (小有名气)
|
[求助]
再请帮忙翻译一段段英文大概意思
|
||
|
Off sheet position in position counts from the IBOX. In the MKII and MKIII frames, which have reference position switches, this is the value of the position count when the Sensor comes to rest against the home position switch after passing the reference position switch. In other frames this value is static and loaded during setup only. The position in position counts of the edge of the product or the fixed edge position entered in the setup pages. These values are useful in determining stability of the product, and edge detection. The position of the sensor head in position counts. This value will update approximately ever five seconds. Target Single Point Position. This is the cross direction position that the sensor will sit at to collect a RFChine direction sample when placed in single point mode. Reference Position Delta. This is the deviation in the location of the reference position switch as detected by the IBOX. The Reference position is considered to be a fixed number at 16384. if encoder pulses are being processes correctly this number will be near zero. |
» 猜你喜欢
一志愿华东师范生物学326分,求调剂
已经有4人回复
071000生物学调剂求助
已经有11人回复
化学工程与技术324调剂
已经有16人回复
298求调剂
已经有4人回复
282,求调剂
已经有9人回复
考研调剂
已经有19人回复
308求调剂
已经有20人回复
中科院总分315求调剂
已经有3人回复
求调剂 材料与工程 324分 专硕
已经有3人回复
一志愿矿大,材料工程专硕314分,0856可调都可以
已经有12人回复

lty1008200
金虫 (小有名气)
- 应助: 0 (幼儿园)
- 金币: 1008.8
- 散金: 15
- 红花: 5
- 帖子: 287
- 在线: 100.1小时
- 虫号: 1214790
- 注册: 2011-02-27
- 性别: GG
- 专业: 粉末冶金与粉体工程
|
不好意思。这是五句不相干的话。误导你翻译了。 1.Off sheet position in position counts from the IBOX. In the MKII and MKIII frames, which have reference position switches, this is the value of the position count when the Sensor comes to rest against the home position switch after passing the reference position switch. In other frames this value is static and loaded during setup only. 2.The position in position counts of the edge of the product or the fixed edge position entered in the setup pages. These values are useful in determining stability of the product, and edge detection. 3.The position of the sensor head in position counts. This value will update approximately ever five seconds. 4.Target Single Point Position. This is the cross direction position that the sensor will sit at to collect a RFChine direction sample when placed in single point mode. 5.Reference Position Delta. This is the deviation in the location of the reference position switch as detected by the IBOX. The Reference position is considered to be a fixed number at 16384. if encoder pulses are being processes correctly this number will be near zero. |

3楼2011-09-14 22:19:28

2楼2011-09-14 21:15:15
★ ★ ★ ★ ★ ★ ★ ★ ★ ★
爱与雨下(金币-10): 屡犯! 2011-09-16 08:49:03
爱与雨下(金币-10): 屡犯! 2011-09-16 08:49:03
|
本帖内容被屏蔽 |
4楼2011-09-15 15:21:36
jwdxbjzh
至尊木虫 (职业作家)
- 翻译EPI: 244
- 应助: 8 (幼儿园)
- 贵宾: 0.015
- 金币: 10699.3
- 散金: 437
- 红花: 30
- 帖子: 3868
- 在线: 1074.8小时
- 虫号: 611748
- 注册: 2008-09-25
- 性别: GG
- 专业: 生物无机化学

5楼2011-09-16 04:07:16













回复此楼