| 查看: 522 | 回复: 1 | ||
| 本帖产生 1 个 翻译EPI ,点击这里进行查看 | ||
于田9858木虫 (小有名气)
|
[求助]
翻译2句话
|
|
|
Experimental Setup. We used epifluorescence microscopy (Nikon TE-2000) to image the polystyrene fluorescent particles and determine the critical dimensions of the devices. The images were recorded on a CCD camera (Cascade IIb, Photometrics). The particle separation images were taken with a 10 objective with a numerical aperture (NA) of 0.3. We used two independent syringe pumps with 1 cm3 syringes (Fisher Scientific, Waltham, MA) and 23 gauge needles (0.5 in.¢¢ long, type 304, i.d. 0.017 in.¢¢, o.d. 0.025 in.¢¢ to pump the bulk fluid and the particle suspensions.The bulk flow rate (QB) was kept 1 cm3/h, and particle flow rate was kept 0.02 cm3/h for all measurements. Fluidic connections were made using Tygon tubing (i.d. 0.02 in.¢¢, o.d. 0.06 in.¢¢, 0.02 in.¢¢ wall; supplier, VWR, Brisbane, CA) and stainless steel tubes (0.025 in.¢¢ o.d. 0.017 in.¢¢ i.d., 0.500 in.¢¢ length; supplier, New England Small Tube, Litchfield, NH). |
» 猜你喜欢
职称评审没过,求安慰
已经有32人回复
垃圾破二本职称评审标准
已经有17人回复
回收溶剂求助
已经有6人回复
投稿Elsevier的Neoplasia杂志,到最后选publishing options时页面空白,不能完成投稿
已经有22人回复
申请26博士
已经有5人回复
EST投稿状态问题
已经有7人回复
毕业后当辅导员了,天天各种学生超烦
已经有4人回复
聘U V热熔胶研究人员
已经有10人回复
求助文献
已经有3人回复
投稿返修后收到这样的回复,还有希望吗
已经有8人回复
8814402
至尊木虫 (职业作家)
- 翻译EPI: 509
- 应助: 18 (小学生)
- 贵宾: 0.381
- 金币: 12916.1
- 散金: 47
- 红花: 16
- 帖子: 4183
- 在线: 357.8小时
- 虫号: 1184404
- 注册: 2011-01-06
- 专业: 药物学其他科学问题
【答案】应助回帖
于田9858(金币+10, 翻译EPI+1): 谢谢 2011-05-30 15:56:41
|
Experimental Setup. 试验装置 We used epifluorescence microscopy (Nikon TE-2000) to image the polystyrene fluorescent particles and determine the critical dimensions of the devices.我们使用落射荧光显微镜为聚苯乙烯荧光粒子成像并确定装置的临界尺寸。 The images were recorded on a CCD camera (Cascade IIb, Photometrics). 图像以CCD相机记录。The particle separation images were taken with a 10 objective with a numerical aperture (NA) of 0.3. 粒子分离图像以10倍物镜在数值孔径0.3获取。We used two independent syringe pumps with 1 cm 3 syringes (Fisher Scientific, Waltham, MA) and 23 gauge needles (0.5 in.¢¢ long, type 304, i.d. 0.017 in.¢¢, o.d. 0.025 in.¢¢ to pump the bulk fluid and the particle suspensions.我们使用两套独立的注射泵(具有1 cm 3注射器和23种剂量规格的针)抽取液体和粒子悬液。 The bulk flow rate (QB) was kept 1 cm3/h, and particle flow rate was kept 0.02 cm3/h for all measurements.所有测定中液体流速保持为1 cm3/h,粒子流速保持为0.02 cm3/h 。Fluidic connections were made using Tygon tubing (i.d. 0.02 in.¢¢, o.d. 0.06 in.¢¢, 0.02 in.¢¢ wall; supplier, VWR, Brisbane, CA) and stainless steel tubes (0.025 in.¢¢ o.d. 0.017 in.¢¢ i.d., 0.500 in.¢¢ length; supplier, New England Small Tube, Litchfield, NH).液体流连接采用聚乙烯管和不锈钢管。 |
2楼2011-05-30 11:05:53













to pump the bulk fluid and the particle suspensions.
回复此楼