| 查看: 1744 | 回复: 8 | |||
| 本帖产生 1 个 翻译EPI ,点击这里进行查看 | |||
| 当前只显示满足指定条件的回帖,点击这里查看本话题的所有回帖 | |||
[交流]
求助一段英语翻译
|
|||
|
A previous cLC method, involving large injection volumes (20 μL) and on-column focusing techniques, provided a suitable sensitivity using an Inertsil? C8 capillary column, DAD and gradient elution. This method showed that composition of the focusing solution, mobile phase and pH have remarkable effects on HA separation. In order to improve this separation, an isocratic cLC method compatible with MS detection was developed and the influence of several chromatographic factors on separation quality evaluated. Different reversed-phase packings such as Luna? C8, Luna? C18, Synergi? Max-RP (C12) and Synergi Fusion (C18 and polar embedded group) were tested using UV-DAD detection. These columns were chosen due to their high efficiencies and bonded phase surface coverage. Considering the different particle sizes, flow rate was set at 15 μL min?1 for both Synergi Fusion? and Synergi? Max-RP, 12 and 9 μL min?1 for Luna? C8 and Luna? C18 columns respectively. Chromatographic conditions were optimized using experimental design methodologies such as central composite design. Factors and ranges selected for the optimization of mobile phase composition were ACN (11.6–28.4%), ammonium acetate concentration (13.2–46.8 mM) and buffer pH (3.6–4.4). Response variables were expressed in terms of resolution, calculated at baseline, between the worst resolved peak pair NH–H (Rs,min), and retention time of the last eluting peak (tend). From the obtained equations, it could be concluded that Rs,min was significantly affected by both ACN percentage and pH while tend only by ACN. In addition, the ammonium acetate concentration had no significant effect on separation. Chromatographic separation efficiency was optimized for Rs,min ≥ 2 and minimum tend value. Luna? C8 capillary column provided poor resolution. Luna? C18 and Synergi? Max-RP columns provided similar Rs,min to Synergi? Fusion but higher efficiencies. However, Synergi? Max-RP column provided poor peak symmetry. Therefore, Luna? C18 column was selected for further optimization with the quadrupole MS detector. Taking into account the instrumental limitations of the MS capillary nebulizer, the ammonium acetate concentration in the mobile phase was fixed to 5 mM. Chromatographic separation was optimized using multifactorial design. Factors and ranges selected were ACN (12–18%) and pH (3.6–4.1). For the injection, buffered focusing solutions with 5% MeOH were used. Table 1 includes the values of the experimental responses (Rs,min and tend), which were fitted into the following normalized polynomial equations: (1)Rs,min=1.74?0.51pH?1.35ACN?0.06pH2+0.39pH ACN+0.40ACN2 (2)tend=12.18+0.18pH?11.02ACN+0.76pH2?0.94pH ACN+4.83 ACN2 Determination coefficients were 0.988 and 0.992 for Rs,min and tend respectively, showing the reliability of the equations. In the studied domain, both ACN percentage and pH affected significantly to Rs,min (p values 0.0000 and 0.0002 respectively) (Eq. (1)) while ACN (%) affected only tend (p value 0.0000 and 0.0005 for the single and quadratic term respectively) (Eq. (2)). As can be expected, the interactions between factors (ACN-pH) were significant only for Rs,min response (p = 0.0033). In Fig. 1 it can be observed that the ACN percentage decrease in the mobile phase increases Rs,min and tend. However, when pH decreases, Rs,min increases and tend does not change significantly. The chromatographic separation efficiency was optimized by maximizing Rs,min and minimizing tend values which maximized the desirability function over the selected region. The maximum desirability function yielded a tend = 13.6 min and Rs,min = 2.2 at pH 3.6 and 14.5% ACN. The estimated response surfaces predicted that Rs,min > 2 and tend in the range 12.5–15.0 min could be obtained at pH 3.6–3.7 and 13–15% ACN. As a compromise, pH 3.6 and 13% ACN were selected as optimum values. Under these conditions tend = 15.0 min and Rs,min = 2.3 were expected and experimentally assessed. Finally, ammonium formate 5 mM was also tested and selected to avoid problems into the capillary MS nebulizer. |
» 猜你喜欢
售SCI一区T0P文章,我:8O.55.1.O.5.4,科目齐全,可+急
已经有5人回复
售SCI-T0P文章,我:8O.5.5.1.O.54,科目齐全,可+急
已经有7人回复
上海工程技术大学 激光智能制造课题组 2027级博士研究生招生
已经有6人回复
课题组招2027级博士 上海工程技术大学 激光智能制造方向
已经有6人回复
现代”学阀”该如何界定
已经有14人回复
求合成方法
已经有8人回复
师弟论文见刊大半年才想起来申请专利,还能抢救一下吗?
已经有4人回复
有机合成以后会不会被AI改变?做科研的虫友怎么看
已经有8人回复
我的奶奶
已经有3人回复
» 抢金币啦!回帖就可以得到:
坐标无锡,诚征女友
+3/964
2026年物理学、化学与数据分析国际会议 (PCDA 2026)
+1/895
2027年航天航空、材料与人工智能国际会议(AMAI 2027)
+1/871
2027年电气工程、自动化与应用工程国际会议(EEAE 2027)
+1/853
2027年生物医学、农业与可持续发展国际会议(BASD 2027)
+1/831
2027年计算机视觉、设计与非遗文化传播国际会议(CVDC 2027)
+1/805
持续创业者,A8离异男征婚,事业遇到瓶颈,寻找生活伴侣
+1/294
石河子大学能源与材料学院李航副教授课题组招收硕、博士
+1/98
石河子大学能源与材料学院李航副教授课题组招收硕、博士
+1/87
南科大薛亚辉课题组诚聘离子输运、二维材料、原子力显微镜等方向“快响行动”博士生
+1/86
南方科技大学力航系急招收纳米材料、力学、机械等方向推免硕士研究生两名
+1/80
上海遇见缘分
+5/75
澳门大学孙鹏展博士课题组招收全奖博士研究生1名
+2/74
【2027硕士招生】招收材料、化工、环境、冶金类硕士研究生
+1/27
废油资源化教育部工程中心 诚聘催化方向特聘研究员
+1/10
大湾区大学姚瑶课题组2027届博士生招生 (与中山大学联合培养)
+1/6
(香港大学)智能制造实验室招收27年春秋季入学全奖博士和硕士研究生
+1/6
从靶点发现到机制验证,肿瘤免疫治疗研究为什么离不开高质量抗体?
+1/1
CAR表达怎么测?定点荧光标记蛋白让流式细胞检测更直接
+1/1
中山大学中山医学院(深圳校区)-肿瘤细胞生物课题组招收联培(客座)硕士/博士生
+1/1
6楼2010-12-07 16:14:54
3楼2010-12-03 18:43:09
5楼2010-12-07 16:12:49
7楼2010-12-07 17:28:31










回复此楼

