| 查看: 1427 | 回复: 8 | |||
| 本帖产生 1 个 翻译EPI ,点击这里进行查看 | |||
| 当前只显示满足指定条件的回帖,点击这里查看本话题的所有回帖 | |||
[交流]
求助一段英语翻译
|
|||
|
A previous cLC method, involving large injection volumes (20 μL) and on-column focusing techniques, provided a suitable sensitivity using an Inertsil? C8 capillary column, DAD and gradient elution. This method showed that composition of the focusing solution, mobile phase and pH have remarkable effects on HA separation. In order to improve this separation, an isocratic cLC method compatible with MS detection was developed and the influence of several chromatographic factors on separation quality evaluated. Different reversed-phase packings such as Luna? C8, Luna? C18, Synergi? Max-RP (C12) and Synergi Fusion (C18 and polar embedded group) were tested using UV-DAD detection. These columns were chosen due to their high efficiencies and bonded phase surface coverage. Considering the different particle sizes, flow rate was set at 15 μL min?1 for both Synergi Fusion? and Synergi? Max-RP, 12 and 9 μL min?1 for Luna? C8 and Luna? C18 columns respectively. Chromatographic conditions were optimized using experimental design methodologies such as central composite design. Factors and ranges selected for the optimization of mobile phase composition were ACN (11.6–28.4%), ammonium acetate concentration (13.2–46.8 mM) and buffer pH (3.6–4.4). Response variables were expressed in terms of resolution, calculated at baseline, between the worst resolved peak pair NH–H (Rs,min), and retention time of the last eluting peak (tend). From the obtained equations, it could be concluded that Rs,min was significantly affected by both ACN percentage and pH while tend only by ACN. In addition, the ammonium acetate concentration had no significant effect on separation. Chromatographic separation efficiency was optimized for Rs,min ≥ 2 and minimum tend value. Luna? C8 capillary column provided poor resolution. Luna? C18 and Synergi? Max-RP columns provided similar Rs,min to Synergi? Fusion but higher efficiencies. However, Synergi? Max-RP column provided poor peak symmetry. Therefore, Luna? C18 column was selected for further optimization with the quadrupole MS detector. Taking into account the instrumental limitations of the MS capillary nebulizer, the ammonium acetate concentration in the mobile phase was fixed to 5 mM. Chromatographic separation was optimized using multifactorial design. Factors and ranges selected were ACN (12–18%) and pH (3.6–4.1). For the injection, buffered focusing solutions with 5% MeOH were used. Table 1 includes the values of the experimental responses (Rs,min and tend), which were fitted into the following normalized polynomial equations: (1)Rs,min=1.74?0.51pH?1.35ACN?0.06pH2+0.39pH ACN+0.40ACN2 (2)tend=12.18+0.18pH?11.02ACN+0.76pH2?0.94pH ACN+4.83 ACN2 Determination coefficients were 0.988 and 0.992 for Rs,min and tend respectively, showing the reliability of the equations. In the studied domain, both ACN percentage and pH affected significantly to Rs,min (p values 0.0000 and 0.0002 respectively) (Eq. (1)) while ACN (%) affected only tend (p value 0.0000 and 0.0005 for the single and quadratic term respectively) (Eq. (2)). As can be expected, the interactions between factors (ACN-pH) were significant only for Rs,min response (p = 0.0033). In Fig. 1 it can be observed that the ACN percentage decrease in the mobile phase increases Rs,min and tend. However, when pH decreases, Rs,min increases and tend does not change significantly. The chromatographic separation efficiency was optimized by maximizing Rs,min and minimizing tend values which maximized the desirability function over the selected region. The maximum desirability function yielded a tend = 13.6 min and Rs,min = 2.2 at pH 3.6 and 14.5% ACN. The estimated response surfaces predicted that Rs,min > 2 and tend in the range 12.5–15.0 min could be obtained at pH 3.6–3.7 and 13–15% ACN. As a compromise, pH 3.6 and 13% ACN were selected as optimum values. Under these conditions tend = 15.0 min and Rs,min = 2.3 were expected and experimentally assessed. Finally, ammonium formate 5 mM was also tested and selected to avoid problems into the capillary MS nebulizer. |
» 猜你喜欢
» 抢金币啦!回帖就可以得到:
南方科技大学纳米-飞秒-超快动力学课题组---诚聘博士后/助理研究员
+1/180
2026年武汉纺织大学材料学院邓波教授团队接收调剂(硕士生4名)
+1/38
福建农林大学材料院招收调剂硕士生
+1/37
招收2026级环境科学方向(专业代码083001)硕士研究生1-2名
+1/36
中山大学地理科学与规划学院退化土壤环境修复课题组招聘博士后及科研助理
+1/35
烟台大学环境与材料工程学院先进储能材料与器件课题组招收材料方向硕士
+2/14
西北工业大学机电学院 复合材料加工制造方向招聘博士后
+1/12
博士招生 | 青岛科技大学(高分子、化学、材料、力学、航天、机电工程、计算机仿真)
+1/10
福建理工大学材料学院招收2026硕士研究生
+1/8
三峡大学 招收调剂(数学、物理学、力学、工学)
+1/8
三峡大学材料与化工学院调剂
+1/7
中山大学(深圳)柔性电子学院2026级博士生招聘
+1/6
博士招生 | 青岛科技大学(高分子、化学、材料、力学、机电工程、计算机仿真)
+1/5
【调剂上岸】985联合培养!1007/1055/08..07..等,医药生化环材计算机,速来!
+1/5
大连工业大学考研调剂
+1/5
☆ ☆ 中山大学附属第七医院肖芷洁课题组诚招分子医学方向硕士生(调剂生) ☆ ☆
+1/4
天津医科大学基础医学院张恒课题组博士后招聘
+1/3
环境微生物与污染控制研究所招收2026硕士研究生
+1/3
2026年江西科技师范大学Tide课题组招收化学、生物、药学、材料相关学硕或专硕调剂生
+1/3
广东江门 五邑大学柔性传感材料与器件研究开发中心 招收0805、0856调剂硕士
+1/2
6楼2010-12-07 16:14:54
3楼2010-12-03 18:43:09
5楼2010-12-07 16:12:49
7楼2010-12-07 17:28:31














回复此楼

