【请教】如何解决cif表中的两个A级错误和一个B级错误
|
|
PLAT022_ALERT_3_A Ratio Unique / Expected Reflections too Low .... 0.51 Test for data completeness. The ratio of the reported number of unique reflections and expected number of reflections for the resolution given is reported. The ratio can be low due to a missing cusp of data when collected with a 2D-detector. Alternatively, the wrong asymmetric part of reciprocal space was collected on a serial detector system. PLAT029_ALERT_3_A _diffrn_measured_fraction_theta_full Low ....... 0.54 Ideally (and a requirement for publication in Acta Crystallographica), this fraction should be close to 1.0 for theta-full greater or equal to sin(theta/lambda) = 0.6 (i.e. 25.24 degrees for MoKa and 67.7 degrees for CuKa radiation). The three major causes of incomplete data sets are: 1 - A missing cusp of data due to data collection by rotation around the spindle axis only (standard on some image-plate systems). Cure: collect an additional data set after remounting the crystal. 2 - The DENZO imageprocessing package has problems with certain strong reflections. They are often excluded from the data set. Cure: Add an additional scan at lower power setting in order to include strong low order reflections. 3 - Incomplete scans, possibly based on erroneously assumed higher than actual symmetry. Note: The default value of _diffrn_measured_fraction_theta_full that is automatically calculated and inserted in the CIF by SHELXL-97 might generate A-level ALERTS when significant numbers of reflections are missing at higher theta values. In order to avoid such an ALERT, substitute the values calculated with the SHELXL instruction 'ACTA 50' for _diffrn_reflns_theta_full and _diffrn_measured_fraction_theta_full respectively. For Mo-radiation, corresponding values of 25 degees (or higher) and 0.99 (or higher) are expected. PLATON may be used to analyse the case at hand (by invoking either the 'FCF-VALIDATION' mode or the 'ASYM-VIEW' mode). [font=黑体]PLAT088_ALERT_3_B Poor Data / Parameter Ratio .................... 7.82 The data/parameter ratio should in general be higher than 10 for a quality structure determination. This ratio can be improved by not refining C-H parameters other than riding on their carrier atom. 加入acta 50也不能解决,说是用'ASYM-VIEW' ,不知如何用? [ Last edited by qhy12 on 2010-9-15 at 17:38 ] |
» 猜你喜欢
中南大学易小艺课题组诚招2026申请-考核制博士生
已经有0人回复
海南师范大学招收化学博士(光电功能材料课题组招收博士研究生)
已经有10人回复
无机化学论文润色/翻译怎么收费?
已经有293人回复
» 本主题相关价值贴推荐,对您同样有帮助:
求两个B级错误的处理方法,非常感谢!
已经有6人回复
check cif文件后的一个A类错误,请问如何解决
已经有4人回复
虫友帮忙解决几个CIF错误!
已经有4人回复
【求助】求cif的B类错误解决43
已经有10人回复
【求助】cif文件中出现的一个A级错误,该如何解决
已经有4人回复
【请教】如何解决cif表中的一个A级错误和两个B级错误
已经有6人回复
【请教】再次求助 cif的A级错误,多谢!!
已经有9人回复
linhua0402313
版主 (文坛精英)
- CMEI: 1
- 应助: 196 (高中生)
- 贵宾: 3.051
- 金币: 70090.5
- 散金: 313
- 红花: 55
- 沙发: 2
- 帖子: 12044
- 在线: 1242.3小时
- 虫号: 295002
- 注册: 2006-11-11
- 专业: 配位化学
- 管辖: 晶体

2楼2010-09-15 17:50:00
cfocus20
至尊木虫 (职业作家)
- 应助: 93 (初中生)
- 贵宾: 0.103
- 金币: 26658.1
- 红花: 12
- 帖子: 3792
- 在线: 810.1小时
- 虫号: 793082
- 注册: 2009-06-12
- 性别: GG
- 专业: 无机合成和制备化学

3楼2010-09-15 20:08:50

4楼2010-09-15 22:48:50
jiangqibai
木虫 (正式写手)
- 应助: 5 (幼儿园)
- 金币: 1188.7
- 散金: 20
- 红花: 8
- 帖子: 510
- 在线: 136.6小时
- 虫号: 983646
- 注册: 2010-03-27
- 性别: GG
- 专业: 有机合成
5楼2010-09-16 17:22:07







回复此楼