| ²é¿´: 356 | »Ø¸´: 4 | |||
| µ±Ç°Ö÷ÌâÒѾ´æµµ¡£ | |||
yhison0614ͳæ (СÓÐÃûÆø)
|
[½»Á÷]
ÖÐÒëÓ¢
|
||
|
1¡¢PET±¡Ä¤´¦Àíǰºó±íÃæÎ¢¹ÛÐÎò²ÉÓÃÈÕ±¾JEOL¹«Ë¾µÄJSM-5900Ð͵ç×ÓɨÃèÏÔ΢¾µ£¬¾¹ý¶Æ½ðÔ¤´¦ÀíÖ®ºó£¬²ÉÓ÷Ŵó±¶Êý5000¡Á½øÐй۲⣻ 2¡¢±íÃæ»¯Ñ§³É·Öͨ¹ýÃÀ¹úNicolet ¹«Ë¾µÄNexus 670Ð͸µÀïÒ¶ºìÍâ¹âÆ×ÒǽøÐзÖÎö£¬ÒÇÆ÷µÄ·Ö±æÂÊΪ0.1cm-1¡£²âÊÔʱ£¬½«Ñù±¾·ÅÈëɨÃè²ÖÖУ¬Ê¹ÓÃ60´Î/Ãë²ÉÑùËÙ¶È£¬¼Ç¼ɨÃ跶ΧÔÚ4000~600cm-1µÄ¹âÆ×¡£ |
» ²ÂÄãϲ»¶
081700ѧ˶£¬323·Ö£¬Ò»Ö¾Ô¸Öйúº£Ñó´óѧÇóµ÷¼ÁѧУ
ÒѾÓÐ8È˻ظ´
283Çóµ÷¼Á
ÒѾÓÐ4È˻ظ´
²ÄÁϹ¤³Ì310ר˶µ÷¼Á
ÒѾÓÐ3È˻ظ´
Ò»Ö¾Ô¸±±¾©»¯¹¤085600 310·ÖÇóµ÷¼Á
ÒѾÓÐ10È˻ظ´
081700£¬311£¬Çóµ÷¼Á
ÒѾÓÐ6È˻ظ´
282Çóµ÷¼Á
ÒѾÓÐ5È˻ظ´
Ò»Ö¾Ô¸9²ÄÁÏѧ˶297ÒѹýÁù¼¶Çóµ÷¼ÁÍÆ¼ö
ÒѾÓÐ9È˻ظ´
278Çóµ÷¼Á
ÒѾÓÐ10È˻ظ´
301Çóµ÷¼Á
ÒѾÓÐ4È˻ظ´
085600£¬×¨Òµ¿Î»¯¹¤ÔÀí£¬321·ÖÇóµ÷¼Á
ÒѾÓÐ11È˻ظ´
charleygan
ÖÁ×ðľ³æ (ÖøÃûдÊÖ)
chlgan
- ·ÒëEPI: 99
- Ó¦Öú: 496 (˶ʿ)
- ¹ó±ö: 0.005
- ½ð±Ò: 13167.2
- É¢½ð: 15
- ºì»¨: 44
- Ìû×Ó: 2396
- ÔÚÏß: 399.5Сʱ
- ³æºÅ: 859768
- ×¢²á: 2009-09-29
- ÐÔ±ð: GG
- רҵ: Ó¦Óø߷Ö×Ó»¯Ñ§ÓëÎïÀí
|
1¡¢The micro-morphology of PET film, which is pretreated by plating gold, is observed with SEM, 5000x, JSM-5900, JEOL Co., Japan. 2¡¢Surface chemical components are determined with FTIR, Nexus 670, Sensibility 0.1cm-1, Nicolet Co., USA. Load the sample in the sample cell and record the spectrum ranged from 4000 to 600cm-1 at sampling speed of 60 per second. |
2Â¥2009-10-19 15:21:38
lixiaod001
½ð³æ (ÕýʽдÊÖ)
- Ó¦Öú: 15 (СѧÉú)
- ½ð±Ò: 1474.5
- Ìû×Ó: 771
- ÔÚÏß: 5.5Сʱ
- ³æºÅ: 688890
- ×¢²á: 2009-01-06
- רҵ: ÌìÈ»Óлú»¯Ñ§
¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï
yhison0614(½ð±Ò+8,VIP+0): 10-21 21:03
yhison0614(½ð±Ò+8,VIP+0): 10-21 21:03
|
1, PET film surface topography before and after treatment using the company's Japanese JEOL model JSM-5900 scanning electron microscope, after gold-plated, after pretreatment, using 5000 ¡Á magnification to observe; 2, the surface chemical composition of the company through the United States Nicolet Model Nexus 670 Fourier transform infrared spectrometer for analysis, instrument has a resolution of 0.1cm-1. Test, a sample is scanned into the warehouse, the use of 60 times / second sampling rate, record scanning range of 4000 ~ 600cm-1 of the spectrum. |
3Â¥2009-10-19 16:05:53
º¬Ð¦ÌìÌì
Òø³æ (ÕýʽдÊÖ)
- Ó¦Öú: 20 (СѧÉú)
- ½ð±Ò: 1211.5
- É¢½ð: 759
- ºì»¨: 4
- Ìû×Ó: 561
- ÔÚÏß: 269.3Сʱ
- ³æºÅ: 480916
- ×¢²á: 2007-12-16
- ÐÔ±ð: GG
- רҵ: ΢ÉúÎïÉúÀíÓëÉúÎﻯѧ
¿´¿´Õâ¸öÔõôÑù
¡ï ¡ï
yhison0614(½ð±Ò+2,VIP+0): 10-21 21:04
yhison0614(½ð±Ò+2,VIP+0): 10-21 21:04
|
1, Effect of treatment on PET membrane surface micro-morphology was examined by JSM-5900 scanning electron microscope (JEOL company, Japan), observed at 5000¡Á after plated pretreatment. 2, The surface chemical composition was analyzed using Nexus 670 Fourier Transform Infrared Spectrometer (Nicolet company, USA), with a resolution of 0.1cm-1, sampling rate: 60 times / s, scanning spectrum range: 400 ~ 600cm-1. |

4Â¥2009-10-19 19:47:25
1. The topographies of PET thin films
¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï
yhison0614(½ð±Ò+10,VIP+0):µÚ¶þ¶Î²»´í 10-21 21:02
yhison0614(½ð±Ò+10,VIP+0):µÚ¶þ¶Î²»´í 10-21 21:02
|
before and after treatments were first thinly coated with Au and then observed using a SEM (Model JSM5900 of JEOL, Japan) at 5000x. 2. The surface compositions of the films were analyzed using a FT-IR spectrometer (Nexus 670 of Ncolet, USA) with a resolution of 0.1 cm-1. During measurements, each sample would first be loaded into the scan chamber and its FT-IR spectrum was subsequently recorded in a wave number range from 400 to 600 cm-1 and at a sampling rate of 60/s. |
5Â¥2009-10-20 15:19:22














»Ø¸´´ËÂ¥