| ²é¿´: 420 | »Ø¸´: 5 | |||
| µ±Ç°Ö÷ÌâÒѾ´æµµ¡£ | |||
feimi-chinaͳæ (ÕýʽдÊÖ)
|
[½»Á÷]
·ÒëһС¶Î
|
||
| ʵ¼ùÖ¤Ã÷£¬ÊäËÍÅ£¶ÙÁ÷Ì壬ÔÚͬµÈÌõ¼þÏ£¬Óë¸Ö¹ÜÏà±È£¬ÊäËÍÁ¿¿ÉÌá¸ß30%ÒÔÉÏ£»ÔÚÊäËÍÃÝÂÉÁ÷Ìåʱ£¬ÊäËÍÁ¿¿ÉÌá¸ß50%ÖÁ200%¡£»»¾ä»°Ëµ£¬ÔÚ±£Ö¤ÊäËÍÁ¿µÄǰÌáÏ£¬¿ÉÒÔÑ¡ÓÃС¿Ú¾¶¹Ü²Ä£¬±ÃµÄÔËÐй¦ÂʿɽµµÍ30%ÒÔÉÏ£¬3Äê×óÓÒ½ÚÔ¼ÄܺĵķÑÓþͿÉÓë¹Ü²ÄͶ×ÊÏàµÖ¡£ |
» ²ÂÄãϲ»¶
£¨µ÷¼Á£©Ò»Ö¾Ô¸±¨¿¼¹þ¶û±õ¹¤Òµ´óѧ0857×ÊÔ´Óë»·¾³×¨Òµ378·Ö¿¼Éú
ÒѾÓÐ6È˻ظ´
262Çóµ÷¼Á
ÒѾÓÐ7È˻ظ´
²ÄÁÏר˶322·Ö
ÒѾÓÐ10È˻ظ´
²ÄÁϵ÷¼Á
ÒѾÓÐ8È˻ظ´
085600£¬320·ÖÇóµ÷¼Á
ÒѾÓÐ8È˻ظ´
Ò»Ö¾Ô¸ ½ÄÏ´óѧ 085602 »¯¹¤×¨Ë¶ 338·ÖÇóµ÷¼Á
ÒѾÓÐ11È˻ظ´
Çóµ÷¼Á
ÒѾÓÐ6È˻ظ´
086000µ÷¼Á
ÒѾÓÐ3È˻ظ´
Çóµ÷¼Á
ÒѾÓÐ4È˻ظ´
0703µ÷¼Á£¬Ò»Ö¾Ô¸Ìì½ò´óѧ319·Ö
ÒѾÓÐ4È˻ظ´
weichang
ľ³æ (ÖøÃûдÊÖ)
prince_of_persia
- Ó¦Öú: 0 (Ó×¶ùÔ°)
- ½ð±Ò: 1450.6
- ºì»¨: 1
- Ìû×Ó: 1248
- ÔÚÏß: 14.2Сʱ
- ³æºÅ: 726937
- ×¢²á: 2009-03-20
- ÐÔ±ð: GG
- רҵ: ½ðÊô·Ç¾§Ì¬¡¢×¼¾§ºÍÄÉÃ×¾§

2Â¥2009-06-18 12:11:44
zhaoshans
Ìú¸Ëľ³æ (СÓÐÃûÆø)
- Ó¦Öú: 0 (Ó×¶ùÔ°)
- ½ð±Ò: 5289.6
- ºì»¨: 1
- Ìû×Ó: 260
- ÔÚÏß: 39Сʱ
- ³æºÅ: 466956
- ×¢²á: 2007-11-24
- ÐÔ±ð: MM
- רҵ: »·¾³¹¤³Ì
¡ï ¡ï ¡ï ¡ï ¡ï
feimi-china(½ð±Ò+5,VIP+0):лл²»´í 6-18 16:11
feimi-china(½ð±Ò+5,VIP+0):лл²»´í 6-18 16:11
|
ʵ¼ùÖ¤Ã÷£¬ÊäËÍÅ£¶ÙÁ÷Ì壬ÔÚͬµÈÌõ¼þÏ£¬Óë¸Ö¹ÜÏà±È£¬ÊäËÍÁ¿¿ÉÌá¸ß30%ÒÔÉÏ£»ÔÚÊäËÍÃÝÂÉÁ÷Ìåʱ£¬ÊäËÍÁ¿¿ÉÌá¸ß50%ÖÁ200%¡£»»¾ä»°Ëµ£¬ÔÚ±£Ö¤ÊäËÍÁ¿µÄǰÌáÏ£¬¿ÉÒÔÑ¡ÓÃС¿Ú¾¶¹Ü²Ä£¬±ÃµÄÔËÐй¦ÂʿɽµµÍ30%ÒÔÉÏ£¬3Äê×óÓÒ½ÚÔ¼ÄܺĵķÑÓþͿÉÓë¹Ü²ÄͶ×ÊÏàµÖ Form the practice point of view, compared with steel, throughput of Newtonian fluid transportation under the same conditions can be increased by more than 30%, while throughput of power-law fluid transportation will be enhanced by 50-200%. In other words, to ensure the premise of throughput, small-bore tubes are reasonable to be selected so that running efficiency of pump is reduced by more than 30%, and if so, it could save the cost of energy consumption for 3 years or so, turned out to be offset with pipe investment. [ Last edited by zhaoshans on 2009-6-18 at 12:15 ] |
3Â¥2009-06-18 12:12:47
weichang
ľ³æ (ÖøÃûдÊÖ)
prince_of_persia
- Ó¦Öú: 0 (Ó×¶ùÔ°)
- ½ð±Ò: 1450.6
- ºì»¨: 1
- Ìû×Ó: 1248
- ÔÚÏß: 14.2Сʱ
- ³æºÅ: 726937
- ×¢²á: 2009-03-20
- ÐÔ±ð: GG
- רҵ: ½ðÊô·Ç¾§Ì¬¡¢×¼¾§ºÍÄÉÃ×¾§
¡ï ¡ï ¡ï ¡ï
feimi-china(½ð±Ò+4,VIP+0):лд 6-18 16:12
feimi-china(½ð±Ò+4,VIP+0):лд 6-18 16:12
|
The practice proved that compared with the steel pipe under the same conditions, the conveying capacity can be enhanced by up to 30% when the Newton fluid was delivered and the convering capacity can be enhanced by 50% to 200%, when the power-law fluid was delivered. In other words, based on the premise of ensuring the conveying capacity, the running power of pump can be decreased by up to 30% by using the steel pipe with the small aperture so that the expense of saving energy cost for three years can compensate the investment in steel materials. ![]() [ Last edited by weichang on 2009-6-18 at 12:41 ] |

4Â¥2009-06-18 12:38:18
longhua7085
ÖÁ×ðľ³æ (ÖøÃûдÊÖ)
- ·ÒëEPI: 1
- Ó¦Öú: 20 (СѧÉú)
- ½ð±Ò: 17811
- ºì»¨: 3
- Ìû×Ó: 2204
- ÔÚÏß: 138.1Сʱ
- ³æºÅ: 724499
- ×¢²á: 2009-03-17
- ÐÔ±ð: GG
- רҵ: ¸ß·Ö×ÓÎïÀíÓë¸ß·Ö×ÓÎïÀí»¯
¡ï ¡ï ¡ï ¡ï
feimi-china(½ð±Ò+4,VIP+0):лл 6-18 16:12
feimi-china(½ð±Ò+4,VIP+0):лл 6-18 16:12
|
Practice has proved that compared with the steel tube,the conveying capacity was increased by 30% under the same conditions when it was used to convey newtonian fluid and 50% to 200% when used to power-law fluid. In other words, tubular products with minor caliber can be selected and put to use when the conveying capacity was ensured. The operating power of the pump will be reduced by more than 30% ,which can save the cost of energy consumption, resulting an offset with the investment in tubular products in 3 years. [ Last edited by longhua7085 on 2009-6-18 at 12:46 ] |
5Â¥2009-06-18 12:44:52
lixiaod001
½ð³æ (ÕýʽдÊÖ)
- Ó¦Öú: 15 (СѧÉú)
- ½ð±Ò: 1474.5
- Ìû×Ó: 771
- ÔÚÏß: 5.5Сʱ
- ³æºÅ: 688890
- ×¢²á: 2009-01-06
- רҵ: ÌìÈ»Óлú»¯Ñ§
¡ï ¡ï ¡ï
feimi-china(½ð±Ò+3,VIP+0):xie 6-22 16:26
feimi-china(½ð±Ò+3,VIP+0):xie 6-22 16:26
| Practice has proved that the Newtonian fluid transport in the same conditions, as compared with steel, throughput can increase by more than 30%; power-law fluid in the transmission, the transmission will increase capacity by 50-200%. In other words, to ensure that the premise of throughput, you can choose small-bore tubes, pumps can reduce operating power by more than 30%, 3 years or so to save the cost of energy consumption can be offset with investment pipe. |
6Â¥2009-06-19 15:08:10














»Ø¸´´ËÂ¥
