24小时热门版块排行榜    

查看: 1472  |  回复: 11
当前只显示满足指定条件的回帖,点击这里查看本话题的所有回帖

沈娟1990

铜虫 (初入文坛)

[求助] 氧化锌防腐测试 已有1人参与

我是电化学小白,最近在做氧化锌防腐。阻抗测试方法是参考的文献上的,如下:
The cleaned steel specimens (1 cm2) were exposed to the 3.50 wt% NaCl solutions without and with X NPs for different immersion times.  The test was performed by IM6e electrochemical workstation (Zahner-Electrik, Germany) in a three electrode cell including steel specimen as working electrode, platinum as counter electrode and saturated Hg/HgO as reference electrode. The frequency range and perturbation of the measurements were 10 kHz-100 mHz and±10 mV, respectively.
但是测试结果和文献中的数据在横纵坐标上有差异。图1为我测的数据。
文献上半圆的半径大概1000左右,而我测的才100左右。
想请教大神:我这样的数据有问题吗?

氧化锌防腐测试
1.jpg
回复此楼
用心做每件事!
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

沈娟1990

铜虫 (初入文坛)

送红花一朵
引用回帖:
9楼: Originally posted by Jackcd12 at 2016-04-13 11:16:30
你的电极不是多孔的话,表观面积应该是2*1cm^2。
对电极大小会影响工作电极电极表面的电场分布的均匀性,一般要求对电极的表面不小于工作电极面积的2-3倍。你用Pt丝作对电极肯定是不合适的,但也不至于导致测得的 ...

关于您是提出的:电极本身就必须活泼,或者,电极封装有问题(电极引线与电极都暴露到溶液中)。我的理解是:
我的工作电极就是直接定制的碳钢块(长4cm×宽1cm×厚0.5cm),只不过在测试前会用砂纸进行打磨,然后用丙酮洗,再烘干。我看文献中用碳钢电极的也是这样前处理,不知道这样做可以吗?
电极的封装:导线是直接从工作站引出来的导线(并没有引其他导线),电极暴露在溶液中的大小(长2cm×宽1cm×厚0.5cm)。
我这样的解释,除了您认为的对电极的问题,我还可以从那些方面检查自己的测试过程?
谢谢您!
用心做每件事!
10楼2016-04-13 14:11:01
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖
查看全部 12 个回答

cxl318

铜虫 (小有名气)

注意坐标的单位!

发自小木虫Android客户端

» 本帖已获得的红花(最新10朵)

2楼2016-04-10 20:10:03
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

cxl318

铜虫 (小有名气)

如果单位没错,证明你的涂层耐蚀性不如文献

发自小木虫Android客户端

» 本帖已获得的红花(最新10朵)

3楼2016-04-10 20:10:55
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

沈娟1990

铜虫 (初入文坛)

送红花一朵
引用回帖:
2楼: Originally posted by cxl318 at 2016-04-10 20:10:03
注意坐标的单位!

单位都是ohm。自己很疑惑
用心做每件事!
4楼2016-04-11 10:40:54
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖