24小时热门版块排行榜    

查看: 339  |  回复: 1
当前主题已经存档。
【有奖交流】积极回复本帖子,参与交流,就有机会分得作者 ljmmarise 的 4 个金币

ljmmarise

至尊木虫 (著名写手)

[交流] 求助:2个C类错误的结局

Alert level C
1. PLAT066_ALERT_1_C Predicted and Reported Transmissions Identical .          ?


2.PLAT790_ALERT_4_C Centre of Gravity not Within Unit Cell: Resd.  #          2     H2 O   
-------------------------------------------------------------------------------
PLAT790 Type_4 Test Whether C.G. Residue in Unitcell Box
--------------------------------------------------------------------------------

Unless for a good reason, molecular species should be transformed
(by symmetry and/or translation) so that their centres of gravity
are close to or within the unitcell bounds. This is a strict rule for the
main species. Deviations from this general rule are for smaller additional
species when relevant for intermolecular interactions with the main species.


--------------------------------------------------------------------------------

最好详细一点,很多网友都有过这种问题,谢谢。
回复此楼
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

xi2004

至尊木虫 (职业作家)

★ ★ ★ ★
ljmmarise(金币+4,VIP+0):Thanks for you help
1. 虽然你报道的吸收类型可能是multi-scan, 但是你在.ins中加了SIZE的指令, 这样CIF中的Tmin Tmax是根据你的晶体尺寸计算出来的理论值, 而不是实际的multi-scan得到的那个数值.

解决办法: 找帮你解结构的那个老师要.

2. 水分子要平移一下, 使其在单胞内, 并靠近主体分子.

[ Last edited by xi2004 on 2008-9-21 at 17:27 ]
xi2004-emuch@163.com
2楼2008-09-21 17:25:10
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖
相关版块跳转 我要订阅楼主 ljmmarise 的主题更新
普通表情 高级回复 (可上传附件)
信息提示
请填处理意见