[求助] ansys怎么限制热量向死单元进行热传递 已有1人参与

为什么我利用ansys的单元生死功能,逐次激活单元,先激活的单元施加恒定的温度,并进行热分析,但是分析后没有被激活的单元会有温度,这是怎么回事?请指导!下面是我的命令:
/PREP7  
ET,1,SOLID70
*SET,L1,0.01
*SET,W1,0.002
*SET,H1,0.001
*SET,TMP_TF,200
*SET,SHIJIAN,0.1  
MP,DENS,1,8400
MP,KXX,1,50
MP,C,1,176
BLC4,-L1/2,-2*W1,2*L1,5*W1,-2*H1
BLC4,0,0,L1,W1,H1

KWPLAN,-1,       9,      16,      10
FLST,2,2,6,ORDE,2   
FITEM,2,1   
FITEM,2,-2  
VSBW,P51X   

KWPLAN,-1,      12,      14,      10
FLST,2,3,6,ORDE,2   
FITEM,2,2   
FITEM,2,-4  
VSBW,P51X   



KWPLAN,-1,      11,      15,      12
FLST,2,5,6,ORDE,4   
FITEM,2,1   
FITEM,2,-2  
FITEM,2,5   
FITEM,2,-7  
VSBW,P51X   


KWPLAN,-1,      11,       9,      15
FLST,2,7,6,ORDE,4   
FITEM,2,1   
FITEM,2,-5  
FITEM,2,8   
FITEM,2,-9  
VSBW,P51X

VGLUE,ALL


LSEL,S,LENGTH,,L1,,,0
LESIZE,ALL,L1/10,,,,0,,,0
LSEL,S,LENGTH,,W1,,,0
LESIZE,ALL,W1,,,,0,,,0
LSEL,S,LENGTH,,H1,,,0
LESIZE,ALL,H1,,,,0,,,0


VMESH,ALL
NUMCMP,ALL
NUMMRG,ALL


/SOLU
rescont,,all,all
ANTYPE,4,NEW
NROPT,FULL
tunif,20     !初始温度
tref,20      !参考温度
kbc,1        !阶跃载荷
ESEL,S,ELEM,,40,49
EKILL,ALL
ALLSEL,ALL
ESEL,S,ELEM,,40
EALIVE,ALL
  ESEL,S,ELEM,,40
*DO,i,1,8,1
  D,NELEM(40,i),TEMP,TMP_TF
  *ENDDO
  TIME,SHIJIAN
ESEL,S,ELEM,,40
NSLE,S,1
SF,ALL,CONV,40,50  
ESEL,S,LIVE
NSLE,S                           
NSEL,INVE
D,ALL,ALL,0  
NSEL,ALL
ESEL,ALL              
SOLVE
save
parsav,,parameter
FINISH


ansys怎么限制热量向死单元进行热传递
QQ截图20151120113520.jpg
回复此楼
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

shgao20

专家顾问 (职业作家)

【答案】应助回帖

感谢参与,应助指数 +1
可以将死单元的导热系数设置为零,在激活时再恢复非零值。
2楼2015-11-22 10:54:01
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

奋斗前行

金虫 (正式写手)

引用回帖:
2楼: Originally posted by shgao20 at 2015-11-22 10:54:01
可以将死单元的导热系数设置为零,在激活时再恢复非零值。

谢谢,我试一下!
3楼2015-11-23 09:09:03
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖