| ²é¿´: 3593 | »Ø¸´: 2 | |||
| µ±Ç°Ö»ÏÔʾÂú×ãÖ¸¶¨Ìõ¼þµÄ»ØÌû£¬µã»÷ÕâÀï²é¿´±¾»°ÌâµÄËùÓлØÌû | |||
jinshuaidгæ (³õÈëÎÄ̳)
|
[½»Á÷]
OEÂÛÎı»¾ÜÁË£¬Éó¸åÈËÒâ¼û±È½ÏÖпϣ¬µ«±à¼Ö±½Ó¾ÜÁËÔõô°ì£¬ÇóÖú£¡ ÒÑÓÐ2È˲ÎÓë
|
||
|
¸÷λ³æÓѺ㬵ÚÒ»´ÎÇóÖú£¬Ï£Íû´ó¼Ò¶à¶à°ïÖú£¬·Ç³£¸Ðл~ ÎÒÊÇ8ÔÂ28ÈÕͶµÄOptics Express£¬µÚÒ»¸öÉó¸åÈË9ÔÂ25ºÅ¸ø³öÁËÉó¸åÒâ¼û£¬µÚ¶þ¸öÉó¸åÈ˽ØÖ¹Éó¸åÈÕÆÚһֱû¸øÉó¸åÒâ¼û£¬±à¼Ò»Ö±µÈÉó¸åÈË£¬½á¹ûÓÖµÈÁËÒ»¸ö¶àÔµ½11ÔÂ10ºÅû¸øÉó¸åÒâ¼û£¬±à¼Ö±½Ó²Î¿¼µÚÒ»¸öÉó¸åÈ˵ÄÒâ¼û¸ø¾Ü¸åÁË£¬¿´ÁËÉó¸åÈ˵ÄÒâ¼û¸Ð¾õÉó¸åÈ˵ÄÒâ¼û±È½ÏÖпϣ¬×Ô¼ºÒ²ÖªµÀÓÐЩÎÊÌâÊÇ×Ô¼º±íÊö²»Ïêϸ»ò²»Çå³þÔì³ÉµÄ£¬²»ÖªµÀÓÐûÓбØÒªÔÙÉêËßһϣ¬Ï£Íû¸÷λ×ÊÉî³æÓÑÌáЩ½¨Ò飬¸Ð¼¤²»¾¡£¡ Dear Dr. ***: We regret to advise you that your manuscript has not been accepted for publication in Optics Express. The reviewer comments are included below. Thank you for submitting your manuscript to Optics Express. If you have any questions, please contact the journal assistant at opex@osa.org. We hope that we will be able to serve you in the future. Sincerely, Yoonchan Jeong Associate Editor, Optics Express --------------------------- Reviewer 1: This is an interesting paper describing a way of numerically optimising a sub-diffraction-limited optical needle. In general the work seems correct and is well described and set into context. In my opinion, the work is somewhat incremental, the primary novelty being in the precise form of optimisation model. The concept has been previously reported and the actual algorithm used is from Matlab. While the optimisation model are novel and useful to other researchers, I do not feel the manuscript ¡°reports important new science¡±. The authors demonstrate several needles, all of which have a FWHM of ¦Ë/3. However, in the case of a lens operating in a medium of refractive index n=1515 and a 40¦Ìm diameter lens with focal length 6¦Ìm, as used here, the NA is 1.45, and thus the diffraction limit is ¦Ë/2NA = ¦Ë/2.9. In this case, the spots are only very slightly sub-diffraction-limited and are not very impressive. The authors should explain why they used spots so close to the diffraction limit. In addition to the above points, I have a number of other suggestions which I think the authors should address to improve the paper before publication. In the middle of page 5, paragraph 1, the authors say ¡°¡the axial side lobes around the optical needle is minimized, in other words, the optical needle contains a significant fraction of the total light energy.¡± This statement is incorrect, as it implies that the energy is distributed in the z direction. In fact, every z plane should contain equal light energy. The needle would contain a significant fraction of the total energy if the RADIAL side lobes were minimised. In their description the genetic algorithm, the authors say that they ¡°reinsert the reserved population to the initial population¡± without saying where the reserved population comes from. I assume they are referring to the best performing individual from the previous generation, preserved under the ¡°elite selection strategy¡±, but this is not clear. The authors should clarify this. Finally it would be helpful if the authors could comment on whether the optical needles they show in fig 2 have any sidebands in the region r>2¦Ìm. I suspect that, as the spots are only slightly sub-diffraction-limited, they do not have any significant side lobes but this should be explicitly stated. |
» ²ÂÄãϲ»¶
¹ú×ÔÈ»ÆÀÉóÒâ¼û
ÒѾÓÐ8È˻ظ´
¹ú×ÔÈ»ÃæÉϸ´ÅÌ~»¶ÓÌÖÂÛ
ÒѾÓÐ14È˻ظ´
ϵͳ²é²»µ½
ÒѾÓÐ11È˻ظ´
ÓжàÉÙÈËÊǽñÌì²éϵͳ֪µÀ½á¹ûµÄ£¿
ÒѾÓÐ18È˻ظ´
Ϊʲô×ÊÖúÊý¸÷´ó¸ßУ¶¼´´Ð¸ߣ¬×Ô¼ºÉêÇëÔõô¾ÍÕâôÄÑ
ÒѾÓÐ12È˻ظ´
ÓÐûÓÐÈÔûÊÕµ½ÐÅÏ¢µÄ
ÒѾÓÐ3È˻ظ´
µ¼Ê¦Í²ۣºÎÒÔõô̯ÉÏÁËÕâô¸ö¼«Æ·Ñо¿Éú£¡
ÒѾÓÐ8È˻ظ´
»ù½ð²»ÖУ¬¹²Ãã
ÒѾÓÐ11È˻ظ´
Â鷳ר¼ÒÃÇ¿´¿´ÆÀίÃǵÄÒâ¼û£¨F¿ÚÃæÉÏ£©
ÒѾÓÐ9È˻ظ´
2026ÄêÒ¶ÆóËï»ù½ð
ÒѾÓÐ6È˻ظ´
ugent
гæ (³õÈëÎÄ̳)
- Ó¦Öú: 3 (Ó×¶ùÔ°)
- ½ð±Ò: 45.1
- Ìû×Ó: 20
- ÔÚÏß: 23.9Сʱ
- ³æºÅ: 3298072
- ×¢²á: 2014-06-29
- רҵ: ¹â×ÓÓë¹âµç×ÓÆ÷¼þ
3Â¥2016-01-07 09:59:50
deepbreath
Ìú³æ (³õÈëÎÄ̳)
- Ó¦Öú: 0 (Ó×¶ùÔ°)
- ½ð±Ò: 8.5
- É¢½ð: 26
- Ìû×Ó: 7
- ÔÚÏß: 6.7Сʱ
- ³æºÅ: 302047
- ×¢²á: 2006-12-02
- רҵ: ÉúÎҽѧ¹â×Óѧ
2Â¥2016-01-07 01:44:13









»Ø¸´´ËÂ¥
30