[求助] 关于铁氰化钾做探针的问题——回复审稿意见已有1人参与

投稿JSSE,审稿人回复的意见没看太懂,跪求解释,我是科研上的新手,请大家赐教
IV) The electrochemical characterization of the nanocomposite uses routine CV (Figure 1) and EIS experiments (Figure 2) with Fe(CN)63-/Fe(CN)64- as a redox probe. In this regard:

a) The use of a redox probe different from the analyte, although widely used in the literature, has a limited validity. See Seeber et al. Functional Materials in Amperometric Sensing, Springer, 2014.(这本书要两千多美元,太贵,买不起……)

b) The authors provide a series of values attributed to the charge transfer resistance in the text in page 7. These values are provided with an unrealistic number of significant figures if replicate experiments are used and have only a definite meaning if the experimental EIS data are fitted to a concrete equivalent circuit.(完全没看懂是啥意思)
回复此楼
……
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

胡琪

铁杆木虫 (著名写手)

【答案】应助回帖

感谢参与,应助指数 +1
第二个问题是你的每一个值得到都应该有具体意义,并且有相应的等效电路图进行拟合作为解释。
天地任我行
2楼2015-08-27 22:34:28
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

曼鱼0429

木虫 (正式写手)

引用回帖:
2楼: Originally posted by 胡琪 at 2015-08-27 22:34:28
第二个问题是你的每一个值得到都应该有具体意义,并且有相应的等效电路图进行拟合作为解释。

我就是把原图的数据导出来,再用ZsimpWin拟合的啊,出来的值分别是:  The Rct of the four electrodes were 48.01 Ω at bare GCE , 26.06 Ω at SWCNTs/GCE, 27.3 Ω at poly(amino acid)/GCE, and 22.45 Ω at poly(amino acid)/SWCNTs/GCE。我实在不知道我该怎么解释了。。。求回复,谢谢您啦
……