| ²é¿´: 395 | »Ø¸´: 3 | |||
| µ±Ç°Ö÷ÌâÒѾ´æµµ¡£ | |||
| µ±Ç°Ö»ÏÔʾÂú×ãÖ¸¶¨Ìõ¼þµÄ»ØÌû£¬µã»÷ÕâÀï²é¿´±¾»°ÌâµÄËùÓлØÌû | |||
xiaocong½ð³æ (ÖøÃûдÊÖ)
|
[½»Á÷]
ÇóÖú¹ØÓÚ»¯Ñ§Îü¸½ÒÇ
|
||
|
ÓÐûÓÐÈËÓùýÂó¿ËºÍ¿µËþµÄ»¯Ñ§Îü¸½ÒÇ,¶¯Ì¬µÄ,ÓÐÊ²Ã´Çø±ðÂð,ÁíÍâÏëÎÊÏ»¯Ñ§Îü¸½ÒǺóÃæÈç¹û½ÓÖÊÆ×µÄ»°,ÖÊÆ×µÄ·åÄÜ·ñ¶¨Á¿,É«Æ×µÄ·å³öÀ´½øÖÊÆ×ÑÓ³Ùʱ¼ä³¤Âð [ Last edited by xiaocong on 2008-6-18 at 08:37 ] |
» ²ÂÄãϲ»¶
¹ú¼Ò¼¶È˲ſÎÌâ×éÕÐÑо¿Éú £¨´ß»¯·½Ïò£©µ÷¼Á
ÒѾÓÐ13È˻ظ´
ÕÐÊÕ˶ʿÑо¿Éú
ÒѾÓÐ27È˻ظ´
ÎïÀí»¯Ñ§ÂÛÎÄÈóÉ«/·ÒëÔõôÊÕ·Ñ?
ÒѾÓÐ115È˻ظ´
[Ìì½ò]ÖйúÃñº½´óѧ ÕÐÊÕ²ÄÁÏÀàÑо¿Éú
ÒѾÓÐ0È˻ظ´
²ÄÁÏÓ뻯¹¤×¨ÒµÓдóÁ¿µ÷¼ÁÖ¸±ê
ÒѾÓÐ9È˻ظ´
¹ú¼Ò´óÈ˲ſÎÌâ×éÕÐÊÕ»¯Ñ§¡¢²ÄÁÏ»¯¹¤Àà2026Äêµ÷¼ÁÉú
ÒѾÓÐ0È˻ظ´
085600µ÷¼Á
ÒѾÓÐ4È˻ظ´
Õãʦ´ó»¯Óë²ÄѧԺ2026ÄêÓдóÁ¿Ë¶Ê¿Ñо¿Éúµ÷¼ÁÃû¶î £¨ÏßÉÏ µ÷¼Á£©
ÒѾÓÐ8È˻ظ´
¼ªÁÖ¹¤³Ì¼¼Êõʦ·¶Ñ§Ôº ²ÄÁÏÓ뻯¹¤ £¨0856£© ÕÐÊÕµ÷¼Á
ÒѾÓÐ5È˻ظ´
¿ÎÌâ×é(»¯Ñ§¡¢»¯¹¤¡¢»·¾³¡¢ÄÜÔ´¡¢²ÄÁÏÏà¹Ø·½Ïò)»¶ÓÄãµÄ¼ÓÈë
ÒѾÓÐ11È˻ظ´
¹ú¼Ò´óÈ˲ſÎÌâ×éÕÐÊÕ»¯Ñ§¡¢²ÄÁÏ»¯¹¤Àà2026Äêµ÷¼ÁÉú
ÒѾÓÐ0È˻ظ´
ypxhp
ľ³æ (СÓÐÃûÆø)
- Ó¦Öú: 0 (Ó×¶ùÔ°)
- ½ð±Ò: 4249.9
- Ìû×Ó: 130
- ÔÚÏß: 325.9Сʱ
- ³æºÅ: 312064
- ×¢²á: 2006-12-30
- ÐÔ±ð: GG
- רҵ: ·ÖÀë¹ý³Ì
¡ï
^_^@^_^(½ð±Ò+1,VIP+0):¶àлÁË£¡
^_^@^_^(½ð±Ò+1,VIP+0):¶àлÁË£¡
|
¸ù¾ÝÂó¿Ë¹«Ë¾µÄ¹Ù·½×ÊÁÏ£¬ÖÊÆ×Ò²ÊÇ¿ÉÒÔ¶¨Á¿µÄ¡£ Application Note 122 AutoChem and Mass Spectrometer Gas Calibration The AutoChem TCD level calibration is a powerful tool for converting raw TCD signals to gas concentrations. This built-in calibration provides the AutoChem with known gas concentrations and records the TCD signal associated with each one. The concentration and signal data are then used to generate a polynomial for converting TCD signals to gas concentrations. This capability can also be used to generate a gas calibration for a mass spectrometer. A concentration calibration for hydrogen was generated to demonstrate this technique. During the AutoChem TCD level calibration, a Pfeiffer ThermoStar (QMS 200) was used to monitor the hydrogen concentration in the gas stream. Typical calibration data are shown in Figure 1. The AutoChem was configured with argon as the carrier gas and 10% hydrogen in argon as the loop gas. The built-in TCD level calibration automatically generated 11 gas concentrations using an internal blender. The AutoChem and the Pfeiffer ThermoStar recorded similar signal profiles for the level calibration. The Pfeiffer ThermoStar data can be exported to an ASCII file, and used to generate a calibration curve. Several commercial software packages (Microsoft Excel, Microcal Origin, and Matlab from Mathworks) are suitable for generating the final calibration curve, Figure 2. The calculated polynomial for the hydrogen gas concentration can be used to convert ThermoStar Ion Current (mass = 2) to hydrogen concentrations. Most commercial mass spectrometers can be used with the AutoChem to generate calibration curves for the mass spectrometer. PDF°æ±¾ Âó¿Ë¹Ù·½ÍøÕ¾ÏÂÔØApplication Note 122 http://www.micromeritics.com/applications/application_notes.aspx µ½ÖÊÆ×ʱ¼äÓ¦¸ÃÓÐËùÑÓ³¤£¬¿´Î¶ȵϰ£¬Ö»¿´TCDÐźÅÎÒÏë¾Í¿ÉÒÔÁ˰ɡ£ |
3Â¥2008-06-18 10:36:12
zouzhq
ÈÙÓþ°æÖ÷ (ÖªÃû×÷¼Ò)
Сľ³æÖ®·çÓêÎÞ×è
- Ó¦Öú: 0 (Ó×¶ùÔ°)
- ¹ó±ö: 3.913
- ½ð±Ò: 14815
- É¢½ð: 546
- ºì»¨: 11
- Ìû×Ó: 5467
- ÔÚÏß: 595.6Сʱ
- ³æºÅ: 429211
- ×¢²á: 2007-08-04
- ÐÔ±ð: GG
- רҵ: ´ß»¯»¯Ñ§
- ¹ÜϽ: ´ß»¯
¡ï
rabbit7708(½ð±Ò+1,VIP+0):¶àлÈÈÐÄÓ¦Öú£¡£º£©
rabbit7708(½ð±Ò+1,VIP+0):¶àлÈÈÐÄÓ¦Öú£¡£º£©
|
ÎÒÃÇÕâÂòÁËÖÊÆ×£¬²»Äܶ¨Á¿£¬¹Ü»¯Ñ§Îü¸½ÒǵÄÄǸöѧÉú»¹Ã»ÓаѶþÕßÁ¬ÆðÀ´Óùý É«Æ×·å³öÀ´½øÖÊÆ×£¬Ê±¼ä¿Ï¶¨ÊÇÓÐÁËÑÓ³Ù°É |

2Â¥2008-06-18 09:05:27
xiaocong
½ð³æ (ÖøÃûдÊÖ)
- Ó¦Öú: 5 (Ó×¶ùÔ°)
- ½ð±Ò: 1234.2
- É¢½ð: 1312
- ºì»¨: 1
- Ìû×Ó: 1037
- ÔÚÏß: 307.5Сʱ
- ³æºÅ: 91626
- ×¢²á: 2005-09-06
- ÐÔ±ð: GG
- רҵ: ¸ß·Ö×Ó²ÄÁÏÓë»·¾³
4Â¥2008-06-19 08:21:31














»Ø¸´´ËÂ¥
10