24小时热门版块排行榜    

查看: 544  |  回复: 1
本帖产生 1 个 翻译EPI ,点击这里进行查看

朱岩0308

银虫 (小有名气)

[求助] 没做过类似的结果分析,翻译出来总感觉不太通顺,求翻译!!!!

Differential scanning calorimetry (DSC) was performed using a Perkine-Elmer DSC 7 in a nitrogen atmosphere at a heating rate of 10 C/min. Thermal gravimetric analysis (TGA) was performed with a PerkineElmer Pyris1 at a heating rate of 20 C/min in a nitrogen or air atmosphere. Dynamic mechanical analysis (DMA) was performed with a PerkineElmer Pyris Diamond DMA with a sample size of 2.0  1.0  0.2 cm. The storage modulus E' and tan d were determined as the sample was subjected to the temperature scan mode at a programmed heating rate of 5 C/min at a frequency of 1 Hz. The test was performed using a bending mode with an amplitude of 5 mm. Thermal mechanical analysis (TMA) was performed with a PerkineElmer Pyris Diamond TMA at a heating rate of 5 C/min. NMR measurements were performed using a Varian Inova 600 NMR in DMSO-d6, and the chemical shift was calibrated by setting the chemical shift of DMSO-d6 as 2.49 ppm. The infrared spectra were recorded using a Nicolet Avatar 320 FTIR spectrophotometer.
在化学路上永远前行~
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

武汉一心一译

捐助贵宾 (著名写手)


【答案】应助回帖

商家已经主动声明此回帖可能含有宣传内容
★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★
朱岩0308: 金币+28, 翻译EPI+1, ★★★★★最佳答案, 多谢 2015-03-05 14:58:15
Differential scanning calorimetry (DSC) was performed using a Perkine-Elmer DSC 7 in a nitrogen atmosphere at a heating rate of 10 C/min. Thermal gravimetric analysis (TGA) was performed with a PerkineElmer Pyris1 at a heating rate of 20 C/min in a nitrogen or air atmosphere.
在氮气环境中,以每分钟上升10摄氏度的加热效率,运用铂金埃尔默公司研制的 DSC7号仪器,进行差示扫描量热。同时,在氮氧环境中,以每分钟上升20摄氏度的加热效率,运用铂金埃尔默公司的Pyris1号仪器,进行热重分析。

Dynamic mechanical analysis (DMA) was performed with a PerkineElmer Pyris Diamond DMA with a sample size of 2.0  1.0  0.2 cm.
运用铂金埃尔默公司研制Pyris Diamond号分析仪对大小为2.0cm*1.0cm*0.2cm的样本,进行动态力学分析。

The storage modulus E' and tan d were determined as the sample was subjected to the temperature scan mode at a programmed heating rate of 5 C/min at a frequency of 1 Hz.
温度扫描模型被调试为每分钟升温5摄氏度,1Hz的频率,测量储能模量E 和介质损耗因数作为样品参数。

The test was performed using a bending mode with an amplitude of 5 mm.
该项测试是在振幅为5mm的弯曲模态上进行的。


Thermal mechanical analysis (TMA) was performed with a PerkineElmer Pyris Diamond TMA at a heating rate of 5 C/min.
以每分钟上升5摄氏度的加热效率,运用铂金埃尔默公司研制的 Pyris Diamond仪器,进行热机分析。

NMR measurements were performed using a Varian Inova 600 NMR in DMSO-d6, and the chemical shift was calibrated by setting the chemical shift of DMSO-d6 as 2.49 ppm.
运用600HZ高磁场核磁共振仪,以氘代二甲亚砜作试剂,进行核磁共振测量。 通过将氘代二甲亚砜的化学位移设定在2.49ppm,从而校准化学位移。

The infrared spectra were recorded using a Nicolet Avatar 320 FTIR spectrophotometer.
运用Nicolet Avatar 320傅里叶红外光谱仪,记录本实验的红外光谱。
2楼2015-03-05 10:07:37
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖
相关版块跳转 我要订阅楼主 朱岩0308 的主题更新
信息提示
请填处理意见