| ²é¿´: 258 | »Ø¸´: 1 | |||
| µ±Ç°Ö÷ÌâÒѾ´æµµ¡£ | |||
| ¡¾ÐüÉͽð±Ò¡¿»Ø´ð±¾ÌûÎÊÌ⣬×÷ÕßHARRY231½«ÔùËÍÄú 4 ¸ö½ð±Ò | |||
HARRY231ľ³æ (СÓÐÃûÆø)
captain
|
[ÇóÖú]
ÇóÖú ·ÒëÎÄÏ×ÕªÒª
|
||
|
Ó¦ÓÃÑùÆ·µÄǰ´¦Àíм¼ÊõSPE½áºÏGC/MSµÄϵͳ·ÖÎö·½·¨£¬½¨Á¢ÁËũҩµÄ¶à²ÐÁô·ÖÎö·½·¨¡£ÀûÓò»Í¬¼«ÐԵĹÌÏàÝÍȡСÖù£¬Í¬Ê±ÌáÈ¡¾»»¯ÉúÎïÑùƷѪҺÖÐ10ÖÖũҩºÍÊóÒ©£¬²¢ÀûÓÃGC/MS¼à²â·ÖÎö½«±£Áôʱ¼ä¡¢ÌØÕ÷Àë×ÓºÍÆ×¿â¼ìË÷Ïà½áºÏ½øÐжàÖ¸±ê¼ì²â¡£ÌáÈ¡¹ý³ÌÖгä·Ö¿¼ÂÇÁ˹ÌÏàÝÍÈ¡µÄ¿ÉÄÜÓ°ÏìÒòËØ£¬¶ÔSPEÝÍÈ¡Ìõ¼þ½øÐÐÓÅ»¯£¬Ñ¡Ôñ³öÁËÑùÆ·ÌáÈ¡µÄ×îÓÅ·½°¸¡£ÀûÓÃÈýÖÖ²»Í¬¼«ÐÔµÄSPEСÖùÌáÈ¡¾»»¯Ð§¹û±È½ÏµÃÖª£¬HLBÖùµÄÝÍȡЧ¹û×î¼Ñ£»´ÓÂȷ¡¢±½¡¢ÒÒËáÒÒõ¥¼°Âȷ£ºÒì±û´¼£¨9£º1£©²»Í¬µÄÏ´ÍѼÁÖÖÀà±ÈÑ¡ºóµÃÖª£¬Ï´ÍѼÁΪÂȷ£¬Ï´ÍѼÁµÄÓÃÁ¿¶¨Î»3mL¡£¼ÓÈë2mLÁ×ËáÑλº³åҺʱЧ¹û×î¼Ñ¡£½á¹û±íÃ÷¸Ã·½·¨ÏµÍ³ÐԺ㬲Ù×÷¼ò±ã£¬¾ßÓнϸߵÄÁéÃô¶È¡¢×¼È·¶ÈºÍ¾«Ãܶȡ£Ìí¼Ó»ØÊÕÂÊÔÚ72.6%~112%Ö®¼ä£¬±äÒìϵÊý¾ùСÓÚ £¬ÍêÈ«·ûºÏũҩ²ÐÁôÌáÈ¡·½·¨ÒªÇó¡£ Ð»Ð»£¡ [ Last edited by HARRY231 on 2008-6-11 at 12:09 ] |
» ²ÂÄãϲ»¶
0703»¯Ñ§
ÒѾÓÐ26È˻ظ´
274Çóµ÷¼ÁÇóµ÷¼Á
ÒѾÓÐ11È˻ظ´
327Çóµ÷¼Á
ÒѾÓÐ10È˻ظ´
µ÷¼Á
ÒѾÓÐ19È˻ظ´
275 Çóµ÷¼Á
ÒѾÓÐ7È˻ظ´
Çó²ÄÁϵ÷¼Á£¬Ò»Ö¾Ô¸Ö£ÖÝ´óѧ289·Ö
ÒѾÓÐ21È˻ظ´
µç×ÓÐÅÏ¢346
ÒѾÓÐ4È˻ظ´
ÇóÖú071001µ÷¼Á£¡£¡£¡
ÒѾÓÐ7È˻ظ´
Ò»Ö¾Ô¸Éî´ó085601²ÄÁϹ¤³Ìרҵ£¨×¨Ë¶£©300·Ö¿ÉÒÔµ÷¼ÁÈ¥ÄÄ
ÒѾÓÐ12È˻ظ´
Ò»Ö¾Ô¸»ª¶«Àí¹¤085601²ÄÁϹ¤³Ì303·ÖÇóµ÷¼Á
ÒѾÓÐ11È˻ظ´

xiongwei3707
Òø³æ (СÓÐÃûÆø)
- Ó¦Öú: 0 (Ó×¶ùÔ°)
- ½ð±Ò: 203.1
- É¢½ð: 1498
- ºì»¨: 1
- Ìû×Ó: 145
- ÔÚÏß: 123.3Сʱ
- ³æºÅ: 532638
- ×¢²á: 2008-03-25
- ÐÔ±ð: GG
- רҵ: ÖÊÆ×·ÖÎö
¡ï
HARRY231(½ð±Ò+1,VIP+0):ллÄúµÄ»Ø¸´£¬µ«ÎÒÐèÒªµÄ²»ÊÇÖ±½ÓgoogleµÄ½á¹û¡£
HARRY231(½ð±Ò+1,VIP+0):ллÄúµÄ»Ø¸´£¬µ«ÎÒÐèÒªµÄ²»ÊÇÖ±½ÓgoogleµÄ½á¹û¡£
| Application of the sample pre-treatment with the new technology SPE GC / MS analysis of the way, the establishment of a multi-pesticide residue analysis. The use of different polarity by SPE column, and purification of biological samples from the blood of 10 pesticides and rat poison, and using GC / MS monitoring and analysis will be retained, the spectral characteristics of ions and retrieval of combining multi-target detection. Give full consideration to the process of extracting the solid phase extraction and the possible effects of factors, the SPE extraction conditions to optimize and select a sample from the optimal programme. Use of three different polarity of the SPE column purifying effect from that comparison, HLB, in the extraction of the best results, from chloroform, benzene, chloroform and ethyl acetate: isopropyl alcohol (9:1) of the wash Delinking of species than that after the election, to get rid of chloroform, get rid of the targeted amount of 3 mL. Adding 2 mL phosphate buffer at the best results. The results showed that the systemic approach, and simple, has a high sensitivity, accuracy and precision. Add in the recovery of 72.6 percent to 112 percent, and the coefficient of variation was less than full compliance with the requirements of pesticide residue extraction methods. |
2Â¥2008-06-11 14:19:16














»Ø¸´´ËÂ¥