ºÏ½ð£¬À©É¢
|
|
¿ÎºóϰÌ⣬ÇóÖú£ºÔÚ¸Ö±íÃæ¶ÉÉÏÒ»²ãNiÀ´±£»¤¸Ö²Ä²»±»¸¯Ê´£¬¶ÉÍêºóÔÚ1100¶È½øÐÐÈÈ´¦Àí£¬Èç¹ûNiº¬Á¿µÍÓÚ60%±ãÎÞ·¨±£»¤¸Ö²Ä£¬ÊÔ¹ÀËã×î´óÈÈ´¦Àíʱ¼ä¡£ÏÖÔÚÓÐÒ»¸Ö²Ä±»ÈÈ´¦ÀíÁË×î´óʱ¼äµÄÒ»°ëʱ¼ä£¬Èç¹ûÒªÈÃËü±£³Ö10Ä꿹¸¯Ê´ÄÜÁ¦£¬Ã¿Äê×î¶à¿ÉÒÔ¸¯Ê´¶àÉÙºÁÃ×£¿ £¨. A steel component is plated with a monolayer of pure Ni as corrosion inhibitor for room temperature service. After plating the component has to be heat treated at 1100 ¡ãC; if the minimum level of protection occurs for a Ni content of 60 %, then estimate the maximum time for which the component can be heat treated. A component is heat treated for half this time, estimate the maximum corrosion rate (mm/year) if the component must retain its corrosion resistance for a minimum of 10 years.£© |