H. Retests
1. General
1.1 If the test sections or specimens specified for a test are not properly taken and prepared, the test results obtained with them shall be invalid. The tests shall then be repeated on properly prepared test specimens.
1.2 If, in a properly performed test, the requirements are not met, then, before the corresponding unit test quantities are rejected, retests may be carried out subject to the conditions stated below. Retests are not allowed if it is suspected that the wrong material is concerned.
1.3 If the unsatisfactory result of a test is due to obvious defects in the execution of the test or to a narrowly defined fault in the test specimen, the result shall be disregarded and the test in question shall be repeated on a test specimen of the same type which shall be taken from the same test section. This also applies to tensile specimens which, when tested, fracture outside the valid measuring length as defined in D.3.4.
1.4 If the unsatisfactory result of a test is attributable to improper heat treatment of the products, they may be resubjected to heat treatment. Subsequently the entire test shall be repeated, and the original test result shall be disregarded.
1.5 The manufacturer may also follow the procedure described in 1.4 in the case of those products which, according to the specifications, may be supplied without heat treatment but which have failed to meet the requirements in this condition.
1.6 If, under test, a large proportion of the products fails because of constantly recurring manufacturing defects, the entire delivery may be rejected.
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

reko34

木虫 (正式写手)

【答案】应助回帖

★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ...
RXMCDM: 金币+1, 多谢应助! 2014-07-11 11:53:57
huangguaha: 金币+166, 翻译EPI+1, ★★★★★最佳答案, 非常感谢~ 2014-07-11 16:12:16
重复试验
1.概述
1.1 如果试验段或试件准备不当,获得的试验结果无效。应在恰当准备的试件上重复试验。
1.2 如果在恰当进行的试验中未达要求,在否决对应的试验数量达到前应根据下列条件进行重复试验。怀疑存在错误材料时不允许重测。
1.3 如果不满意的结果来自明显的执行错误或试件上的狭义错误,应无视结果并在取自同一试验段的同类试件上重复试验。本条还用于试验时在D.3.4定义的合理测试长度之外出现断裂的拉伸样件。
1.4 如果不满意的结果来自产品的不当热处理,可以对其再作热处理。然后重复整个试验,原试验应无视。
1.5 对于根据技术规范在供货时可不作热处理、但在此条件下未能满足要求的产品,生产商也可根据1.4所述流程操作。
1.6 如果试验中大部分产品应反复出现的制造问题失效,应否决整批供货。