| ²é¿´: 531 | »Ø¸´: 1 | |||
| ±¾Ìû²úÉú 1 ¸ö ·ÒëEPI £¬µã»÷ÕâÀï½øÐв鿴 | |||
zb6824785ľ³æ (СÓÐÃûÆø)
|
[ÇóÖú]
ÇóÖú¹ØÓÚ¶¥¿ÕÆøÏàÉ«Æ×·½ÃæµÄÎÄÏ×·Ò루ÖÐÒëÓ¢£©
|
||
|
É«Æ×Ìõ¼þ ECD ¼ì²âÆ÷,³ØµçÁ÷0.5nA, Á¿³Ì10¡£10%OV-17¹Ì¶¨Ïà, 2m*2mm ²»Ðâ¸ÖÌî³äÖù, ¸ß´¿µªÔØÆø, ÖùÁ÷ËÙ35ml/min¡£ÖùζÈ70¡æ, ¼ì²âÆ÷ζÈ280¡æ , ×¢Éä¿ÚζÈ150¡æ,½øÑù 300¦Ìl¶¥¿ÕÆøÌå¡£ FID ¼ì²âÆ÷,Á¿³Ì10,¸ß´¿µªÔØÆø,²»Ðâ¸ÖÌî³äÖù2m *2mm, 80~ 100Ä¿,10% OV- 101 ¹Ì¶¨Ïà( Shimadzu ¹«Ë¾),ÖùÁ÷ËÙ30ml/min, ÖùÎÂ60¡æ , ¼ì²âÆ÷ºÍ×¢Éä¿ÚζÈ150¡æ, ¿ÕÆøÁ÷ ËÙ300ml/min,ÇâÆøÁ÷30ml/min¡£ FPD¼ì²âÆ÷,Á¿³Ì10,¸ß´¿µªÔØÆø,´ó¿×¾¶µ¯ÐÔʯӢëϸÖù12m * 0.53mm * 0.25¦Ìm, SE- 54 ¹Ì¶¨Ïà, ÖùÁ÷ 30ml/min, ÖùÎÂ60¡æ, ¼ì²âÆ÷ºÍ×¢Éä¿ÚζÈ150¡æ,¿ÕÆøÁ÷ËÙ60ml/min, ÇâÆøÁ÷ËÙ60ml/min¡£ |
» ²ÂÄãϲ»¶
284Çóµ÷¼Á
ÒѾÓÐ10È˻ظ´
һ־Ըɽ¶«´óѧҩѧѧ˶Çóµ÷¼Á
ÒѾÓÐ4È˻ظ´
07»¯Ñ§280·ÖÇóµ÷¼Á
ÒѾÓÐ4È˻ظ´
298-Ò»Ö¾Ô¸Öйúũҵ´óѧ-Çóµ÷¼Á
ÒѾÓÐ12È˻ظ´
Çó²ÄÁÏ£¬»·¾³×¨Òµµ÷¼Á
ÒѾÓÐ3È˻ظ´
335Çóµ÷¼Á
ÒѾÓÐ5È˻ظ´
Çóµ÷¼Á
ÒѾÓÐ7È˻ظ´
Ò»Ö¾Ô¸¼ª´ó»¯Ñ§322Çóµ÷¼Á
ÒѾÓÐ4È˻ظ´
»·¾³Ñ§Ë¶288Çóµ÷¼Á
ÒѾÓÐ8È˻ظ´
341Çóµ÷¼Á(Ò»Ö¾Ô¸ºþÄÏ´óѧ070300)
ÒѾÓÐ6È˻ظ´
luo27xiao
ÖÁ×ðľ³æ (ÖøÃûдÊÖ)
- ·ÒëEPI: 1
- Ó¦Öú: 0 (Ó×¶ùÔ°)
- ½ð±Ò: 13181.8
- É¢½ð: 200
- ºì»¨: 7
- Ìû×Ó: 1529
- ÔÚÏß: 360.9Сʱ
- ³æºÅ: 1218202
- ×¢²á: 2011-03-02
- רҵ: °ëµ¼Ìå¹âµç×ÓÆ÷¼þ
¡¾´ð°¸¡¿Ó¦Öú»ØÌû
¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï
zb6824785: ½ð±Ò+30, ·ÒëEPI+1, ¡ï¡ï¡ï¡ï¡ï×î¼Ñ´ð°¸, ·Ç³£¸Ðл£¬Í¬Ê±ºÜ±§Ç¸ÓÉÓÚÕ⼸ÌìÊÂÇé±È½Ï¶àûÄܼ°Ê±ÆÀ¼Û£¬ÍûÀí½â£¡ 2014-01-14 18:39:52
zb6824785: ½ð±Ò+30, ·ÒëEPI+1, ¡ï¡ï¡ï¡ï¡ï×î¼Ñ´ð°¸, ·Ç³£¸Ðл£¬Í¬Ê±ºÜ±§Ç¸ÓÉÓÚÕ⼸ÌìÊÂÇé±È½Ï¶àûÄܼ°Ê±ÆÀ¼Û£¬ÍûÀí½â£¡ 2014-01-14 18:39:52
|
Chromatographic conditions ECD detector cell current 0.5nA, Range 10. 10% OV-17 stationary phase , 2m * 2mm stainless steel packed column , High purity nitrogen carrier gas , column flow 35ml/min.Column temperature of 70 ¡æ, detector temperature 280 ¡æ, the injection port temperature 150 ¡æ, injection 300¦Ìl headspace . FID detector , range 10 , high purity nitrogen carrier gas , stainless steel packed column 2m * 2mm, 80 ~ 100 mesh , 10% OV-101 Stationary phase (Shimadzu Corporation) , the column flow rate 30ml/min, column temperature 60 ¡æ, injection port and detector temperature 150 ¡æ, the air flow Speed 300ml/min, hydrogen flow 30ml/min. FPD detector , range 10 , high purity nitrogen carrier gas , large diameter fused silica capillary column 12m * 0.53mm * 0.25¦Ìm, SE-54 stationary phase column flow 30ml/min, column temperature 60 ¡æ, detector and injection port temperature 150 ¡æ, the air flow rate 60ml/min, Hydrogen flow rate 60ml/min |
2Â¥2014-01-11 18:30:58













»Ø¸´´ËÂ¥