24小时热门版块排行榜    

查看: 1202  |  回复: 12

灯泡3204

木虫 (著名写手)

引用回帖:
9楼: Originally posted by yytsnake at 2013-05-04 20:35:58
已经精修的可以了,你自己可根据需要再做适当的调整即可。同时对结构的正确与否根据自己的实验进行相关的判断。

感谢您的帮组,我在检查cif文件的时候出现以下错误:
The following ALERTS were generated. Each ALERT has the format
       test-name_ALERT_alert-type_alert-level.
Click on the hyperlinks for more details of the test.
--------------------------------------------------------------------------------Alert level A
PLAT417_ALERT_2_A Short Inter D-H..H-D       H6     ..  H6      ..       1.37 Ang.
--------------------------------------------------------------------------------Alert level B
PLAT035_ALERT_1_B No _chemical_absolute_configuration info given .          ?
PLAT417_ALERT_2_B Short Inter D-H..H-D       H5     ..  H6      ..       2.07 Ang.
--------------------------------------------------------------------------------Alert level C
RINTA01_ALERT_3_C  The value of Rint is greater than 0.12
            Rint given   0.152
STRVA01_ALERT_4_C           Flack parameter is too small
           From the CIF: _refine_ls_abs_structure_Flack   -0.700
           From the CIF: _refine_ls_abs_structure_Flack_su    1.600
PLAT048_ALERT_1_C MoietyFormula Not Given ........................          ?
PLAT125_ALERT_4_C No '_symmetry_space_group_name_Hall' Given .....          ?
PLAT340_ALERT_3_C Low Bond Precision on  C-C Bonds ...............     0.0052 Ang  
--------------------------------------------------------------------------------Alert level G
PLAT005_ALERT_5_G No _iucr_refine_instructions_details  in the CIF          ?
PLAT007_ALERT_5_G Note: Number of Unrefined Donor-H Atoms ........          4      
PLAT032_ALERT_4_G Std. Uncertainty on Flack Parameter Value High .      1.600      
PLAT093_ALERT_1_G No su's on H-positions, refinement reported as .      mixed     
PLAT791_ALERT_4_G Note: The Model has Chirality at C7     (Verify)          R      
And 8 other PLAT791 Alerts
More ...
A类错误我不知道什么意思,怎么改,麻烦您再指点一下,谢谢!
11楼2013-05-07 08:34:53
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

yytsnake

至尊木虫 (职业作家)

A类错误主要上O6上H的位置不合适,需人工调整其位置,以消除此A类错误。
12楼2013-05-07 14:55:43
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

灯泡3204

木虫 (著名写手)

引用回帖:
12楼: Originally posted by yytsnake at 2013-05-07 14:55:43
A类错误主要上O6上H的位置不合适,需人工调整其位置,以消除此A类错误。

怎么调整呢?我删掉H6,然后ENVI O6,老是出现错误,麻烦您指导我一下
B类错误:PLAT417_ALERT_2_B Short Inter D-H..H-D       H5     ..  H6      ..       2.07 Ang.
又怎么去改呢
谢谢呢?
13楼2013-05-07 14:59:22
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖
相关版块跳转 我要订阅楼主 灯泡3204 的主题更新
信息提示
请填处理意见