The absolute value of parameter shift to su ratio > 0.20
            Absolute value of the parameter shift to su ratio given   1.537
            Additional refinement cycles may be required.
PLAT080_ALERT_2_A Maximum Shift/Error ............................       1.54      
PLAT122_ALERT_1_A No _symmetry_space_group_name_H-M Given ........          ?
PLAT222_ALERT_3_A Large Non-Solvent    H    Uiso(max)/Uiso(min) ..       10.0 Ratio
Alert level B
PLAT052_ALERT_1_B Info on Absorption Correction Method Missing ...          ?
PLAT053_ALERT_1_B Minimum Crystal Dimension Missing (or Error) ...          ?
PLAT054_ALERT_1_B Medium  Crystal Dimension Missing (or Error) ...          ?
PLAT055_ALERT_1_B Maximum Crystal Dimension Missing (or Error) ...          ?
PLAT111_ALERT_2_B ADDSYM Detects (Pseudo) Centre of Symmetry .....        100 PerFi
PLAT213_ALERT_2_B Atom C30             has ADP max/min Ratio .....        4.1 prola
PLAT220_ALERT_2_B Large Non-Solvent    C     Ueq(max)/Ueq(min) ...        4.3 Ratio
PLAT230_ALERT_2_B Hirshfeld Test Diff for    C24    --  C25     ..       10.3 su   
PLAT230_ALERT_2_B Hirshfeld Test Diff for    C29    --  C30     ..        8.8 su   
PLAT355_ALERT_3_B Long    O-H Bond (0.82A)   O8     -   H8B    ...       1.12 Ang.
PLAT417_ALERT_2_B Short Inter D-H..H-D       H4     ..  H7B     ..       1.91 Ang.
回复此楼
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

yytsnake

至尊木虫 (职业作家)

【答案】应助回帖

★ ★ ★ ★ ★
感谢参与,应助指数 +1
应用人生: 金币+5, ★★★很有帮助 2013-04-23 17:29:21
精修不收敛,需继续精修。
加H不正确,在精修后,删除原来的H,继续加H。
游离水上的H方向不对,需人工调整。