24小时热门版块排行榜    

查看: 709  |  回复: 2

cddc77

金虫 (小有名气)

[求助] cif文件检测出现错误,怎么解决?

如题!错误列表如下:
SYMM001_ALERT_1_A  _symmetry_cell_setting is missing
            The cell setting should be one of the following
            *  triclinic
            *  monoclinic
            *  orthorhombic
            *  tetragonal
            *  rhombohedral
            *  trigonal
            *  hexagonal
            *  cubic
            The following tests will not be performed.
            SYMMS_01,SYMMS_02
SYMM003_ALERT_1_A  _symmetry_space_group_name_H-M is missing
            Space-group symbol, including unique axis.
            The following tests will not be performed.
            CELLZ_01,CHEMW_03,REFLT_03,SYMMG_01,SYMMG_02
CELL003_ALERT_1_A  _cell_measurement_reflns_used is missing
            Number of reflections used to measure unit cell.
CELL004_ALERT_1_A  _cell_measurement_theta_min is missing
            Minimum theta of reflections used to measure unit cell.
            The following tests will not be performed.
            CELLT_01
CELL005_ALERT_1_A  _cell_measurement_theta_max is missing
            Maximum theta of reflections used to measure unit cell.
            The following tests will not be performed.
            CELLT_01
EXPT005_ALERT_1_A  _exptl_crystal_description is missing
            Crystal habit description.
            The following tests will not be performed.
            CRYSR_01
EXPT010_ALERT_1_A  _exptl_crystal_colour (_pd_char_colour for powder) is missing
            Crystal colour.
            The following tests will not be performed.
            CRYSC_01
DIFF003_ALERT_1_A  _diffrn_measurement_device_type is missing
            Diffractometer make and type. Replaces _diffrn_measurement_type.
DIFF005_ALERT_1_A  _diffrn_measurement_method is missing
            Mode of intensity measurement and scan.
DIFF019_ALERT_1_A  _diffrn_standards_number is missing
            Number of standards used in measurement.
DIFF020_ALERT_1_A  _diffrn_standards_interval_count and
            _diffrn_standards_interval_time are missing. Number of measurements
            between standards or time (min) between standards.
DIFF022_ALERT_1_A  _diffrn_standards_decay_% is missing
            Percentage decrease in standards intensity.
ABSTY01_ALERT_1_A  The absorption correction should be one of the following
            *  none
            *  analytical
            *  integration
            *  numerical
            *  gaussian
            *  empirical
            *  psi-scan
            *  multi-scan
            *  refdelf
            *  sphere
            *  cylinder
PLAT122_ALERT_1_A No _symmetry_space_group_name_H-M Given ........          ?
PLAT366_ALERT_2_A Short? C(sp?)-C(sp?) Bond  C17    -   C18    ...       1.18 Ang.


--------------------------------------------------------------------------------


Alert level B
PLAT052_ALERT_1_B Info on Absorption Correction Method Missing ...          ?
PLAT093_ALERT_1_B No su's on H-atoms, but refinement reported as .      mixed  
该怎么解决啊?谢谢
回复此楼
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

cluster8676

至尊木虫 (著名写手)

【答案】应助回帖

★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★
感谢参与,应助指数 +1
linhua0402313: 金币+1, 感谢回帖交流,欢迎常来晶体板块 2012-11-07 07:50:53
cddc77: 金币+20, ★★★很有帮助, 谢谢 2012-11-07 08:19:39
以上的问题都是你没有填写一些信息导致的。 在生成最终的cif文件之前要填写一些东西的。我们一般把pcf文件里面的东西填到cif里面。你这里唯一一个问题就是LAT366_ALERT_2_A Short? C(sp?)-C(sp?) Bond  C17    -   C18    ...       1.18 Ang. 可能要做些限制。

B类错误里面,第一个 一般是填Multi-Scan 第二个把mix改成constr。
学无止境
2楼2012-11-06 21:58:38
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

cddc77

金虫 (小有名气)

直接在cif中填写可以吗?C17-C18是三键。
3楼2012-11-07 06:43:51
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖
相关版块跳转 我要订阅楼主 cddc77 的主题更新
信息提示
请填处理意见