| ²é¿´: 4802 | »Ø¸´: 10 | ||
| µ±Ç°Ö»ÏÔʾÂú×ãÖ¸¶¨Ìõ¼þµÄ»ØÌû£¬µã»÷ÕâÀï²é¿´±¾»°ÌâµÄËùÓлØÌû | ||
xiaojian123Òø³æ (³õÈëÎÄ̳)
|
[ÇóÖú]
Áò´ú°Í±ÈÍ×Ëá²â¶¨Ð¡Âó¸ùϵ±û¶þÈ©£¨MDA£©º¬Á¿£¬ÏÔʾ»ÆÂÌÉ«¶ø²»ÊÇ·ÛºìÉ«£¿ ÒÑÓÐ1È˲ÎÓë
|
|
| ÓÃÁò´ú°Í±ÈÍ×Ëá²â¶¨Ð¡Âó¸ùϵ±û¶þÈ©£¨MDA£©º¬Á¿£¬ÎÞÂÛÓÃPBSÑÐÄ¥»¹ÊÇ1%µÄTCAÑÐÄ¥£¬ÌáȡҺºÍTBA£¨0.5%£©·´Ó¦ºóΪʲô×ÜÊÇÏÔʾ»ÆÂÌÉ«¶ø²»ÊÇʵÑé˵µÄÄÇÖÖ·ÛºìÉ«£¿ÇóÖúÕâÊÇʲôÔÒò£¿ |
» ²ÂÄãϲ»¶
0817 »¯Ñ§¹¤³Ì 299·ÖÇóµ÷¼Á ÓпÆÑоÀú ÓжþÇøÎÄÕÂ
ÒѾÓÐ4È˻ظ´
0854¿É¿çµ÷¼Á£¬Ò»×÷Ò»ÏîºËÐÄÂÛÎÄÎåÏîרÀû£¬Ê¡¡¢¹ú¼¶Ö¤Êé40+ÊýÒ»Ó¢Ò»287
ÒѾÓÐ5È˻ظ´
070300»¯Ñ§319Çóµ÷¼Á
ÒѾÓÐ6È˻ظ´
Ò»Ö¾Ô¸985£¬±¾¿Æ211£¬0817»¯Ñ§¹¤³ÌÓë¼¼Êõ319Çóµ÷¼Á
ÒѾÓÐ6È˻ظ´
Ò»Ö¾Ô¸Î÷ÄϽ»´ó£¬Çóµ÷¼Á
ÒѾÓÐ3È˻ظ´
286Çóµ÷¼Á
ÒѾÓÐ6È˻ظ´
½¹ÂÇ
ÒѾÓÐ11È˻ظ´
331Çóµ÷¼Á£¨0703Óлú»¯Ñ§
ÒѾÓÐ7È˻ظ´
298-Ò»Ö¾Ô¸Öйúũҵ´óѧ-Çóµ÷¼Á
ÒѾÓÐ5È˻ظ´
297Çóµ÷¼Á
ÒѾÓÐ5È˻ظ´
» ±¾Ö÷ÌâÏà¹Ø¼ÛÖµÌùÍÆ¼ö£¬¶ÔÄúͬÑùÓаïÖú:
ËÜÁÏ×¢ËÜʹÓÃÉ«·Û£¬ÈçºÎÅжÏÉ«·Û±äÖÊ
ÒѾÓÐ6È˻ظ´
ÇóÖú£¡TLCÁòËáÏÔÉ«ºóΪ»ÆÉ«£¬Éî»ÆÉ«£¬´ó¸ÅÊÇÄÄÀ໯ºÏÎï £¿£¿£¿
ÒѾÓÐ16È˻ظ´
Áò´ú°Í±ÈÍ×Ëá·¨²â¶¨MDAʱ£¬0.6%µÄÁò´ú°Í±ÈÍ×Ëáµ½µ×Ó¦¸ÃÔõôÅä°¡£¿
ÒѾÓÐ6È˻ظ´
Ö²ÎïÌåÄÚ¸¬°±ËáºÍ±û¶þÈ©MDAº¬Á¿µÄ²â¶¨·½·¨
ÒѾÓÐ8È˻ظ´
É«·Û¡¢ÑÕÁÏ¡¢È¾ÁÏÈýÕßµÄÇø±ð
ÒѾÓÐ14È˻ظ´
TBA²â¶¨µÄÎÊÌâ
ÒѾÓÐ15È˻ظ´
±û¶þÈ©MDAµÄ²â¶¨ÎÊÌâ
ÒѾÓÐ8È˻ظ´
protein hplc assay discuss
ÒѾÓÐ5È˻ظ´
ÂÈÆø½«Áò´úÎïת»¯Îª»Çõ£Âȵĺó´¦Àí
ÒѾÓÐ8È˻ظ´
smile1122
½ð³æ (СÓÐÃûÆø)
- Ó¦Öú: 0 (Ó×¶ùÔ°)
- ½ð±Ò: 1235
- ºì»¨: 1
- Ìû×Ó: 75
- ÔÚÏß: 17.9Сʱ
- ³æºÅ: 2063120
- ×¢²á: 2012-10-15
- ÐÔ±ð: MM
- רҵ: Ö²ÎïÉúÀíÓëÉú»¯
9Â¥2013-12-25 16:19:47
zhmdwf
ľ³æ (ÖøÃûдÊÖ)
- Ó¦Öú: 1 (Ó×¶ùÔ°)
- ½ð±Ò: 3342.6
- É¢½ð: 5
- Ìû×Ó: 1010
- ÔÚÏß: 141.5Сʱ
- ³æºÅ: 273625
- ×¢²á: 2006-08-20
- ÐÔ±ð: GG
- רҵ: ÉúÎﻯѧ
¡¾´ð°¸¡¿Ó¦Öú»ØÌû
¡ï ¡ï
¸Ðл²ÎÓ룬ӦÖúÖ¸Êý +1
silicare: ½ð±Ò+2, лл²ÎÓë 2012-08-31 18:21:27
¸Ðл²ÎÓ룬ӦÖúÖ¸Êý +1
silicare: ½ð±Ò+2, лл²ÎÓë 2012-08-31 18:21:27
|
Áò´ú°Í±ÈÍ×Ëá²â¶¨ÉúÎïÌåϵÄڵıû¶þÈ©ÊÇ´æÔںܶà¸ÉÈųɷ֣¬¼´¼ÙÑôÐԳɷֶ࣬ÏÖÔÚ¶¼ÓÃMDA-DNPH½áºÏµÄHPLC,¸üºÃµÄ·½·¨¡£¡£¡£ R. Mateos, E. Lecumberri, S. Ramos, L. Goya, L. Bravo, Determination of malondialdehyde (MDA) by high-performance liquid chromatography in serum and liver as a biomarker for oxidative stress: Application to a rat model for hypercholesterolemia and evaluation of the effect of diets rich in phenolic antioxidants from fruits, J. Chromatogr. B 827(2005) 76-82 N. Tukozkan, H. Erdamar, I. Seven, Measurement of total malondialdehyde in plasma and tissues by high-performance liquid chromatography and thiobarbituric acid assay, Firat Tip Dergisi 11 (2006) 88-92. |
2Â¥2012-04-10 21:53:41
xiaojian123
Òø³æ (³õÈëÎÄ̳)
- Ó¦Öú: 0 (Ó×¶ùÔ°)
- ½ð±Ò: 253
- ºì»¨: 1
- Ìû×Ó: 23
- ÔÚÏß: 59.8Сʱ
- ³æºÅ: 1379294
- ×¢²á: 2011-08-25
- ÐÔ±ð: GG
- רҵ: Ö²ÎïÉúÀíÓëÉú»¯
3Â¥2012-04-11 12:24:05
ÈÃÄãѧÖÖÌï
гæ (СÓÐÃûÆø)
- Ó¦Öú: 1 (Ó×¶ùÔ°)
- ½ð±Ò: 867.5
- ºì»¨: 1
- Ìû×Ó: 64
- ÔÚÏß: 13.4Сʱ
- ³æºÅ: 1202728
- ×¢²á: 2011-02-13
- רҵ: Ô°ÒÕ×÷Îï²ÉºóÉúÎïѧ

4Â¥2012-07-14 08:42:22













»Ø¸´´ËÂ¥