[求助]
DNA测定
|
||
| 请问DNA测定体系中一般要考察什么条件啊? |
» 猜你喜欢
招博士
已经有5人回复
青椒八年已不青,大家都被折磨成啥样了?
已经有6人回复
救命帖
已经有9人回复
青年基金C终止
已经有3人回复
26申博求博导推荐-遥感图像处理方向
已经有4人回复
限项规定
已经有7人回复
西南交通大学国家级人才团队2026年博士研究生招生(考核制)—机械、材料、力学方向
已经有3人回复
英文综述是否需要润色及查重
已经有5人回复
为什么nbs上溴 没有产物点出现呢
已经有9人回复


16楼2012-08-25 09:34:23
gaoyang636
木虫 (著名写手)
- BioEPI: 17
- 应助: 202 (大学生)
- 金币: 4111.4
- 散金: 7
- 红花: 14
- 帖子: 1108
- 在线: 159.8小时
- 虫号: 384065
- 注册: 2007-05-27
- 专业: 基因组学
2楼2012-03-19 08:38:52

3楼2012-03-19 14:58:40
xstarsky
铁杆木虫 (正式写手)
- BioEPI: 2
- 应助: 60 (初中生)
- 金币: 6806.4
- 红花: 2
- 帖子: 536
- 在线: 221.3小时
- 虫号: 67896
- 注册: 2005-05-15
- 专业: 作物分子育种
【答案】应助回帖
★ ★
感谢参与,应助指数 +1
王寿梅: 金币+2 2012-03-22 14:32:58
感谢参与,应助指数 +1
王寿梅: 金币+2 2012-03-22 14:32:58
|
Spectrophotometry and fluorometry are commonly used to measure DNA concentration. Spectrophotometrycan be used to measure microgram quantities of pure DNA samples (i.e., DNA that is not contaminated by proteins, phenol, agarose, or RNA). Fluorometry is more sensitive, allowing measurement of nanogram quantities of DNA, and furthermore the use of Hoechst 33258 dye allows specific analysis of DNA. 1。Spectrophotometry DNA concentration can be determined by measuring the absorbance at 260 nm (A260) in a spectrophotometer using a quartz cuvette. For greatest accuracy, readings should be between 0.1 and 1.0. An absorbance of 1 unit at 260 nm corresponds to 50 μg genomic DNA per ml (A260 =1 ⇒ 50 μg/ml)*. This relation is valid only for measurements made at neutral pH, therefore, samples should be diluted in a low-salt buffer with neutral pH (e.g., Tris·Cl, pH 7.0). An example of the calculation involved in nucleic acid quantification when using a spectrophotometer is provided in “Spectrophotometric Measurement of Nucleic Acid Concentration” 1)If you will use more than one cuvette to measure multiple samples, the cuvettes must be matched. 2)Spectrophotometric measurements do not differentiate between DNA and RNA, so RNA contamination can lead to overestimation of DNA concentration. 3)Phenol has an absorbance maximum of 270–275 nm, which is close to that of DNA. Phenol contamination mimics both higher yields and higher purity, because of an upward shift in the A260 value. 2.Fluorometry Fluorometry allows specific and sensitive measurement of DNA concentration by use of the fluorochrome Hoechst 33258, which shows increased emission at 458 nm when bound to DNA. This dye has little affinity for RNA, allowing accurate quantification of DNA samples that are contaminated with RNA.DNA standards and samples are mixed with Hoechst 33258 and measured in glass or acrylic cuvettes using a scanning fluorescence spectrophotometer or a dedicated filter fluorometer set at an excitation wavelength of 365 nm and an emission wavelength of 460 nm. The sample measurements are then compared to the standards to determine DNA concentration. 1)As Hoechst 33258 preferentially binds AT-rich DNA, use standards with a similar base composition to the sample DNA. |