24小时热门版块排行榜    

查看: 961  |  回复: 2

apiper

铜虫 (初入文坛)

[求助] 【求助】fluent单机双核并行运算,网线拔出后运行终止,不能任何操作了

【求助】fluent单机双核并行运算了一晚上,网线拔出后运行终止,不能继续iterate,不能write,也不能显示display。好像什么东西都不行了,请教这该如何继续下一步操作,还是只能重新运算?

The Parallel FLUENT process could not be started.

999999 (..\..\src\mpsystem.c@1123): mpt_read: failed: errno = 10054

999999: mpt_read: error: read failed trying to read 4 bytes: No such file or directory
unable to read the cmd header on the pmi context, Undefined dynamic error code.
op_read error on left context: Undefined dynamic error code
unable to read the cmd header on the left context, Undefined dynamic error code.
op_read error on parent context: Undefined dynamic error code
unable to read the cmd header on the parent context, Undefined dynamic error code.
connection to my parent broken, aborting.
state machine failed.

Interrupting...
Done.

[ Last edited by apiper on 2011-9-15 at 10:04 ]
回复此楼
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

heattransfet

新虫 (职业作家)

【答案】应助回帖

★ ★
臭水沟(金币+2): 谢谢应助~~ 2011-09-15 16:22:51
要连网计算就一直连着

否则就一开始计算就不连网

不能在计算时中断网
此号从今天(2012-06-25)开始不用了。。。。。。。。
2楼2011-09-15 11:13:55
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

47425804

木虫 (正式写手)


【答案】应助回帖

★ ★
xiegangmai(金币+2): 谢谢应助! 2011-09-21 07:02:04
是的,就是这样。
单机并行也是通过网络端口传送数据,拔掉网线或插入网线会导致端口信息发生变化,数据传输出错。
读一个之前保存的cas和dat,再算。
如果没有设置自动保存,那就只能重新算。
3楼2011-09-20 22:56:37
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖
相关版块跳转 我要订阅楼主 apiper 的主题更新
信息提示
请填处理意见