24小时热门版块排行榜    

查看: 452  |  回复: 1

phoebusliu

银虫 (小有名气)

[求助] 氢能源 返回来的意见求助,回答完成之后给20个金币

1。Fig 2: ml min-1
Fig 3: intensity/a.u.
Fig 4: mV s-1

All titles axes in figures should be expressed as:
S.I Unit/S.I Measure Unit
Please change  (这里是让我改啥?不是很明白他的意思)
2。Why was the scan rate maintained 10mVS-1 while in normal corrosion studies  it is 1 or1.67mV mVS-1(这里我用了线性扫描研究了析氢活性,我不明白审稿人怎么用扫描腐蚀的速率来和它比,速度如此之慢)

3。Expression of potential: The Voltage vs. RHE or NHE will be familiar to readers(实验过程中运用了Hg/HgO电极,因为是在碱性溶液当中)

请教各位上面三个问题我该如何回答。
回复此楼
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

tory04

木虫 (著名写手)

【答案】应助回帖

phoebusliu(金币+10): 感谢你的回复。 2011-05-13 12:13:26
引用回帖:
Originally posted by phoebusliu at 2011-05-12 14:44:45:
1。Fig 2: ml min-1
Fig 3: intensity/a.u.
Fig 4: mV s-1

All titles axes in figures should be expressed as:
S.I Unit/S.I Measure Unit
Please change  (这里是让我改啥?不是很明白他的意思)
2。 ...

1:就是让你改单位的书写方式

All titles axes in figures should be expressed as: S.I Unit/S.I Measure Unit

图中的坐标值用国际标准单位书写,书写方式是 :mL/min而不是ml min-1

2: Why was the scan rate maintained 10mVS-1 while in normal corrosion studies  it is 1 or1.67mV mVS-1(这里我用了线性扫描研究了析氢活性,我不明白审稿人怎么用扫描腐蚀的速率来和它比,速度如此之慢)

你可以向他解释这么做的原因

3:Expression of potential: The Voltage vs. RHE or NHE will be familiar to readers

审稿人的意见是电势的参比最好用读者熟悉的RHE或者NHE(我也不知道是什么,可能是你们这个方向常用的参比电极吧)。

如果你不得不用Hg/HgO,你可以换算一下,或者跟审稿人解释为什么必须用Hg/HgO电极
坚持每天都来领红包
2楼2011-05-13 11:56:57
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖
相关版块跳转 我要订阅楼主 phoebusliu 的主题更新
信息提示
请填处理意见