[求助] 出现了这个错误

*Warning* max. SCF cycles performed but system has not reached the groundstate.
  
Current total energy, E     =  -31296.82674049     eV
Current free energy (E-TS)  =  -31296.99898255     eV
(energies not corrected for finite basis set)

NB est. 0K energy (E-0.5TS)      =  -31296.91286152     eV

  ****************************************************************************
  Warning: electronic minimisation did not converge when finding ground state.
  ****************************************************************************
  Writing checkpoint file...

Writing model to 3D_Atomistic.check
Error check_elec_ground_state : electronic_minimisation of initial cell failed.
Current trace stack:
check_elec_ground_state
castep
Error check_elec_ground_state : electronic_minimisation of initial cell failed.
Current trace stack:
check_elec_ground_state
castep
Error check_elec_ground_state : electronic_minimisation of initial cell failed.
Current trace stack:
check_elec_ground_state
castep
Error check_elec_ground_state : electronic_minimisation of initial cell failed.
Current trace stack:
check_elec_ground_state
castep
Error check_elec_ground_state : electronic_minimisation of initial cell failed.
Current trace stack:
check_elec_ground_state
castep
Error check_elec_ground_state : electronic_minimisation of initial cell failed.
Current trace stack:
check_elec_ground_state
castep
MPI Application rank 0 exited before MPI_Finalize() with status 1
无法收敛怎么调参数?
回复此楼
神马都是浮云
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

fagege2010

铁虫 (小有名气)

谢谢是不是把SCF的值变小,收敛次数就会增多
神马都是浮云
3楼2011-04-21 09:58:48
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖