24小时热门版块排行榜    

查看: 589  |  回复: 8
当前主题已经存档。
当前只显示满足指定条件的回帖,点击这里查看本话题的所有回帖

313309925

金虫 (正式写手)

[交流] 求助 进来看看

Alert level A
PLAT220_ALERT_2_A Large Non-Solvent    C     Ueq(max)/Ueq(min) ...       5.38 Ratio
PLAT222_ALERT_3_A Large Non-Solvent    H     Ueq(max)/Ueq(min) ...       5.67 Ratio
Alert level B
PLAT242_ALERT_2_B Check Low       Ueq as Compared to Neighbors for        C14



谢谢了
回复此楼
努力
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

313309925

金虫 (正式写手)

引用回帖:
Originally posted by dongyang5028 at 2009-12-11 08:29:
simu 0.001 3.8 $c
simu 0.001 3.8 $h
精修一下,就没有A B 问题了。

大侠 按你的方法又有新错误了
Alert level A
PLAT242_ALERT_2_A Check Low       Ueq as Compared to Neighbors for         C7     
PLAT242_ALERT_2_A Check Low       Ueq as Compared to Neighbors for        C15     
Given ........          ?
--------------------------------------------------------------------------------Alert level B
PLAT220_ALERT_2_B Large Non-Solvent    C     Ueq(max)/Ueq(min) ...       4.32 Ratio
PLAT222_ALERT_3_B Large Non-Solvent    H     Ueq(max)/Ueq(min) ...       4.90 Ratio
PLAT234_ALERT_4_B Large Hirshfeld Difference C7     --  C8      ..       0.26 Ang.
--------------------------------------------------------------------------------

请指点 多谢啊
努力
4楼2009-12-11 09:54:10
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖
查看全部 9 个回答

jlu_huangl

银虫 (正式写手)


313309925(金币+1,VIP+0): 12-11 09:56
问下楼主,是什么东西啊?写清楚点了
2楼2009-12-11 00:12:03
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

dongyang5028

金虫 (正式写手)

★ ★
313309925(金币+1,VIP+0): 12-11 09:54
eeqeeq0002(金币+1,VIP+0):谢谢 参与 12-13 16:15
simu 0.001 3.8 $c
simu 0.001 3.8 $h
精修一下,就没有A B 问题了。
3楼2009-12-11 08:29:44
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

313309925

金虫 (正式写手)

引用回帖:
Originally posted by jlu_huangl at 2009-12-11 00:12:
问下楼主,是什么东西啊?写清楚点了

PLAT220 Type_2 Test Ueq(max)/Ueq(Min) range for non-H atoms in non-solvent
--------------------------------------------------------------------------------

This test reports on a larger than usual U(eq) range for the specified
element type in the non-solvent/anion part of the structure.
Too high or too low Ueq's may be an indication for incorrectly
identified atomic species (i.e. O versus N).

PLAT222 Type_3 Test Ueq(max)/Ueq(Min) range for H atoms in non-solvent
--------------------------------------------------------------------------------


This test reports on a larger than usual range of U(eq) values for hydrogen
atoms in the non-solvent/anion part of the structure.
Possibe causes are:
1 - disorder, e.g. in t-butyl moieties.
2 - poor data, not adequate for the refinement of individual displacement
     parameters.
3 - Misplaced hydrogen atoms (i.e. there is no density at the position
     where one of the H-atoms is positioned).

这是详细情况  参考下  多谢le
努力
5楼2009-12-11 09:56:03
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖
普通表情 高级回复(可上传附件)
信息提示
请填处理意见