½ð¹Ü¸»¼¯-¹ú²úÀäÔ×ÓÓ«¹â¹âÆ×·¨²â¶¨¿Õµ÷¿ÅÁ£ÎïÖеĹ¯ Õª Òª ͨ¹ý¶Ô¹ú²úÔ×ÓÓ«¹âÒǽøÑùϵͳ½øÐиÄÔ죬²ÉÓÃÔÚÏßÈȽâÑùÆ·½ð¹Ü¸»¼¯ÀäÔ×ÓÓ«¹â·¨²â¶¨¿Õµ÷¿ÅÁ£ÎïÖеĹ¯¡£ÊÔÑùÈȽâζÈΪ700¡«750OC£¬½ð¹ÜÊÍ·ÅζÈΪ5500C£¬ÊÔÑùÔØÆøÁ÷ËÙΪ120 mL/min¡£·½·¨¼ì³öÏÞΪ1pg£¬¹¯º¬Á¿ÔÚ0¡«1.5ng·¶Î§ÄÚ³ÊÏßÐÔ¹ØÏµ£¬²â¶¨±ê׼ƫ²îΪ2.23%¡£Óùú¼ÒÍÁÈÀ±ê×¼GBW07410ÖеĹ¯ÑéÖ¤ÁË·½·¨µÄ׼ȷÐÔ£¬²¢¶ÔijҽԺ¿Õµ÷¿ÅÁ£ÎïÖй¯º¬Á¿½øÐÐÁË·ÖÎö¡£ ¹Ø¼ü´Ê ÀäÔ×ÓÓ«¹â£¬¿Õµ÷£¬¿ÅÁ£Î¹¯ |
» ²ÂÄãϲ»¶
323·Ö£¨¼ÆËã»úÊÓ¾õºÍ´óÄ£ÐÍÏîÄ¿£©ÄÜÖ±½ÓÉÏÊÖ
ÒѾÓÐ3È˻ظ´
¸´ÊÔµ÷¼Á
ÒѾÓÐ3È˻ظ´
311·Ö 22408 Çóµ÷¼Á
ÒѾÓÐ3È˻ظ´
320·ÖÈ˹¤ÖÇÄܵ÷¼Á
ÒѾÓÐ7È˻ظ´
Ò»Ö¾Ô¸Ö£´ó0705Çóµ÷¼Á
ÒѾÓÐ4È˻ظ´
0703»¯Ñ§
ÒѾÓÐ10È˻ظ´
301Çóµ÷¼Á
ÒѾÓÐ10È˻ظ´
306·Ö²ÄÁÏÓ뻯¹¤Çóµ÷¼Á
ÒѾÓÐ6È˻ظ´
²ÄÁϵ÷¼Á
ÒѾÓÐ11È˻ظ´
324Çóµ÷¼Á
ÒѾÓÐ9È˻ظ´

syh9288
¾èÖú¹ó±ö (ÖøÃûдÊÖ)
º£¾üÉϽ«
- ·ÒëEPI: 6
- Ó¦Öú: 2 (Ó×¶ùÔ°)
- ½ð±Ò: 1606.6
- É¢½ð: 543
- ºì»¨: 1
- Ìû×Ó: 1072
- ÔÚÏß: 480.2Сʱ
- ³æºÅ: 735351
- ×¢²á: 2009-03-30
- ÐÔ±ð: GG
- רҵ: ÓлúºÏ³É
½ö¹©²Î¿¼
¡ï ¡ï
jim5362(½ð±Ò+2,VIP+0): 11-14 18:48
jim5362(½ð±Ò+2,VIP+0): 11-14 18:48
|
Gold tube for enriching - the domestic cold atomic fluorescence spectrometry for testing mercury's quantity of particles in airconditioner abstract:through improving the domestic atomic fluorescence spectrometer system,we pyrolysis sample by heating through the method of Gold tube for enriching - the domestic cold atomic fluorescence spectrometry for testing mercury's quantity of particulates in airconditioner. Sample pyrolysis temperature is 700-750OC,the releasing temperature for gold tube is 5500C, speed of gas flow for carrying sample is 120 mL/min.The detection limit of method is 1pg, the content of mercury is in linear relationship within the scope of 0 ~ 1.5 ng, standard deviation is 2.23%.Mercury's quantity of GBW07410 proved the accuracy of the method, and the particles in a hospital's airconditioner is analyzed for testing mercury's content. Keywords cold atomic fluorescence, airconditioner, particle, mercury |

2Â¥2009-11-14 14:19:35
ghw521
½ð³æ (ÖøÃûдÊÖ)
- ·ÒëEPI: 2
- Ó¦Öú: 0 (Ó×¶ùÔ°)
- ½ð±Ò: 116.9
- É¢½ð: 2332
- ºì»¨: 7
- Ìû×Ó: 1343
- ÔÚÏß: 237.6Сʱ
- ³æºÅ: 759646
- ×¢²á: 2009-04-28
- ÐÔ±ð: GG
- רҵ: Ò©Îﻯѧ
¡ï ¡ï ¡ï ¡ï ¡ï ¡ï
jim5362(½ð±Ò+6,VIP+0): 11-14 18:48
jim5362(½ð±Ò+6,VIP+0): 11-14 18:48
|
Gold canal enrichment-homemade cold atomic fluorescence spectrometry determine mercury in air particulate matter Abstract Though homemade atomic fluorescence spectrometry sampling system ameliorated, the mercury of air particulate matter were determined with the Gold canal-line pyrolysis sample enrichment cold atomic fluorescence . The temperature of Sample pyrolysis was 700¡æ~750¡æ, the release temperature of gold canal was 550¡æ,the flow rate of the sample carrier gas was 120 mL/min. The method detection limit was 1pg,the mercury content present linear relationship in the range of 0~1.5ng , the determination standard deviation was 2.23%.The accuracy of the method was verified by Hg of National Soil standard GBW07410 and the mercury content of a hospital in air particulate matter were analyzed. Key words cold atomic fluorescence, air conditioning, particulate matter, mercury. |

3Â¥2009-11-14 14:46:08
bisili
Òø³æ (ÕýʽдÊÖ)
- Ó¦Öú: 1 (Ó×¶ùÔ°)
- ½ð±Ò: 559
- Ìû×Ó: 857
- ÔÚÏß: 54·ÖÖÓ
- ³æºÅ: 878649
- ×¢²á: 2009-10-20
- ÐÔ±ð: MM
- רҵ: ÖÐÎ÷Ò½½áºÏÁÙ´²»ù´¡
¡ï ¡ï
jim5362(½ð±Ò+2,VIP+0): 11-14 18:48
jim5362(½ð±Ò+2,VIP+0): 11-14 18:48
|
Gold enrichment - domestic cold atomic fluorescence spectrometry air particulates mercury Picking through on domestic atomic fluorescence spectrometer system, using online pyrolysis sample gold cold atomic fluorescence spectrometry enriched air particulates mercury. Sample pyrolysis temperature for the 700-750OC, gold 5500C temperature for release, sample carrier gas flow for 120 mL/min. Methods detection limit, mercury content for 1pg in 0 ~ 1.5 ng linear relationship within the scope, standard deviation is 2.23%. In countries GBW07410 standard of soil mercury proved the accuracy of the method, and the air particles in a hospital mercury content is analyzed. Keywords cold atomic fluorescence, air conditioning, particle, mercury |
4Â¥2009-11-14 15:52:07














»Ø¸´´ËÂ¥