| 查看: 194 | 回复: 3 | |||
| 当前主题已经存档。 | |||
jim5362金虫 (正式写手)
|
[交流]
翻译一摘要
|
||
|
金管富集-国产冷原子荧光光谱法测定空调颗粒物中的汞 摘 要 通过对国产原子荧光仪进样系统进行改造,采用在线热解样品金管富集冷原子荧光法测定空调颗粒物中的汞。试样热解温度为700~750OC,金管释放温度为5500C,试样载气流速为120 mL/min。方法检出限为1pg,汞含量在0~1.5ng范围内呈线性关系,测定标准偏差为2.23%。用国家土壤标准GBW07410中的汞验证了方法的准确性,并对某医院空调颗粒物中汞含量进行了分析。 关键词 冷原子荧光,空调,颗粒物,汞 |
» 猜你喜欢
有时候真觉得大城市人没有县城人甚至个体户幸福
已经有5人回复
酰胺脱乙酰基
已经有9人回复
CSC & MSCA 博洛尼亚大学能源材料课题组博士/博士后招生|MSCA经费充足、排名优
已经有5人回复
有70后还继续奋斗在职场上的吗?
已经有6人回复
博士延得我,科研能力直往上蹿
已经有7人回复
退学或坚持读
已经有27人回复
面上基金申报没有其他的参与者成吗
已经有5人回复
遇见不省心的家人很难过
已经有22人回复

syh9288
捐助贵宾 (著名写手)
海军上将
- 翻译EPI: 6
- 应助: 2 (幼儿园)
- 金币: 1598.6
- 散金: 543
- 红花: 1
- 帖子: 1046
- 在线: 475.4小时
- 虫号: 735351
- 注册: 2009-03-30
- 性别: GG
- 专业: 应用高分子化学与物理
仅供参考
★ ★
jim5362(金币+2,VIP+0): 11-14 18:48
jim5362(金币+2,VIP+0): 11-14 18:48
|
Gold tube for enriching - the domestic cold atomic fluorescence spectrometry for testing mercury's quantity of particles in airconditioner abstract:through improving the domestic atomic fluorescence spectrometer system,we pyrolysis sample by heating through the method of Gold tube for enriching - the domestic cold atomic fluorescence spectrometry for testing mercury's quantity of particulates in airconditioner. Sample pyrolysis temperature is 700-750OC,the releasing temperature for gold tube is 5500C, speed of gas flow for carrying sample is 120 mL/min.The detection limit of method is 1pg, the content of mercury is in linear relationship within the scope of 0 ~ 1.5 ng, standard deviation is 2.23%.Mercury's quantity of GBW07410 proved the accuracy of the method, and the particles in a hospital's airconditioner is analyzed for testing mercury's content. Keywords cold atomic fluorescence, airconditioner, particle, mercury |

2楼2009-11-14 14:19:35
★ ★ ★ ★ ★ ★
jim5362(金币+6,VIP+0): 11-14 18:48
jim5362(金币+6,VIP+0): 11-14 18:48
|
Gold canal enrichment-homemade cold atomic fluorescence spectrometry determine mercury in air particulate matter Abstract Though homemade atomic fluorescence spectrometry sampling system ameliorated, the mercury of air particulate matter were determined with the Gold canal-line pyrolysis sample enrichment cold atomic fluorescence . The temperature of Sample pyrolysis was 700℃~750℃, the release temperature of gold canal was 550℃,the flow rate of the sample carrier gas was 120 mL/min. The method detection limit was 1pg,the mercury content present linear relationship in the range of 0~1.5ng , the determination standard deviation was 2.23%.The accuracy of the method was verified by Hg of National Soil standard GBW07410 and the mercury content of a hospital in air particulate matter were analyzed. Key words cold atomic fluorescence, air conditioning, particulate matter, mercury. |

3楼2009-11-14 14:46:08
★ ★
jim5362(金币+2,VIP+0): 11-14 18:48
jim5362(金币+2,VIP+0): 11-14 18:48
|
Gold enrichment - domestic cold atomic fluorescence spectrometry air particulates mercury Picking through on domestic atomic fluorescence spectrometer system, using online pyrolysis sample gold cold atomic fluorescence spectrometry enriched air particulates mercury. Sample pyrolysis temperature for the 700-750OC, gold 5500C temperature for release, sample carrier gas flow for 120 mL/min. Methods detection limit, mercury content for 1pg in 0 ~ 1.5 ng linear relationship within the scope, standard deviation is 2.23%. In countries GBW07410 standard of soil mercury proved the accuracy of the method, and the air particles in a hospital mercury content is analyzed. Keywords cold atomic fluorescence, air conditioning, particle, mercury |
4楼2009-11-14 15:52:07













回复此楼