A类错误,怎么解决?
|
|
|
Alert level A CELL003_ALERT_1_A _cell_measurement_reflns_used is missing Number of reflections used to measure unit cell. CELL004_ALERT_1_A _cell_measurement_theta_min is missing Minimum theta of reflections used to measure unit cell. The following tests will not be performed. CELLT_01 CELL005_ALERT_1_A _cell_measurement_theta_max is missing Maximum theta of reflections used to measure unit cell. The following tests will not be performed. CELLT_01 DIFF019_ALERT_1_A _diffrn_standards_number is missing Number of standards used in measurement. DIFF020_ALERT_1_A _diffrn_standards_interval_count and _diffrn_standards_interval_time are missing. Number of measurements between standards or time (min) between standards. DIFF022_ALERT_1_A _diffrn_standards_decay_% is missing Percentage decrease in standards intensity. 这些A类错误是什么意思?怎么解决? |

★ ★ ★ ★ ★
eeqeeq0002(金币+2,VIP+0):谢谢参与 9-13 10:20
lijianghua2007(金币+1,VIP+0):谢谢你,很详细! 9-14 09:12
lijianghua2007(金币+2,VIP+0):最后2个还是给你啊! 9-14 09:14
eeqeeq0002(金币+2,VIP+0):谢谢参与 9-13 10:20
lijianghua2007(金币+1,VIP+0):谢谢你,很详细! 9-14 09:12
lijianghua2007(金币+2,VIP+0):最后2个还是给你啊! 9-14 09:14
|
CELL003_ALERT_1_A _cell_measurement_reflns_used is missing Number of reflections used to measure unit cell. 晶胞探测使用的衍射点数 CELL004_ALERT_1_A _cell_measurement_theta_min is missing Minimum theta of reflections used to measure unit cell. The following tests will not be performed. CELLT_01 晶胞探测的最小theta角 CELL005_ALERT_1_A _cell_measurement_theta_max is missing Maximum theta of reflections used to measure unit cell. The following tests will not be performed. CELLT_01 晶胞探测的最大theta角 这三个数据应该在给你的信息文件里,如: _cell_measurement_reflns_used 2919 _cell_measurement_theta_min 2.14 _cell_measurement_theta_max 28.24 DIFF019_ALERT_1_A _diffrn_standards_number is missing Number of standards used in measurement. DIFF020_ALERT_1_A _diffrn_standards_interval_count and _diffrn_standards_interval_time are missing. Number of measurements between standards or time (min) between standards. DIFF022_ALERT_1_A _diffrn_standards_decay_% is missing Percentage decrease in standards intensity. 这三个是监测晶体的指标,多数仪器已经不用了。如果你采集数据是用CCD衍射仪,那这三个后面都填 “ ? ” 就可以了,如: _diffrn_standards_number ? _diffrn_standards_interval_count ? _diffrn_standards_interval_time ? _diffrn_standards_decay_% ? [ Last edited by monoclinic on 2009-9-12 at 23:16 ] |
2楼2009-09-12 23:15:00
244073931
至尊木虫 (著名写手)
- 应助: 19 (小学生)
- 金币: 11180.5
- 散金: 33
- 红花: 5
- 帖子: 2433
- 在线: 643.8小时
- 虫号: 448985
- 注册: 2007-11-02
- 性别: GG
- 专业: 金属有机化学
3楼2009-09-13 09:39:26
4楼2009-09-13 12:41:58
l_viking
木虫 (小有名气)
- 应助: 0 (幼儿园)
- 金币: 3117.3
- 帖子: 97
- 在线: 22.3小时
- 虫号: 754406
- 注册: 2009-04-22
- 性别: GG
- 专业: 无机超分子化学
5楼2009-09-13 13:16:32













回复此楼