| 查看: 335 | 回复: 2 | ||
| 【奖励】 本帖被评价2次,作者staphlee增加金币 2 个 | ||
| 当前主题已经存档。 | ||
[资源]
一篇有关Ueq(displacement parameter,温度因子)的文献(作者建議不要稱它溫度因子)
|
||
|
一篇有关Ueq(atomic displacement parameter (ADP), or 温度因子)的文献 这篇主要讲到有关Ueq现在的命名合不合适...有很多计算....我把最主要总结的地方给copy出来给各位虫友....对计算有兴趣的自己去下载全文吧....其中在第6.的地方有讨论到不适合称这个term为温度因子...这也是作者的意见啦...还是满多人再用这个名词的...大家看看. ...参考一下..... from Acta Cryst. (1996). A52, 770-781. http://d.namipan.com/d/aa88c4255 ... e4ff079c2bbb6f71300 4. Recommendations 1. The term anisotropic displacement parameters (abbreviated ADPs) should be used in referring to the individual atomic coefficients in the exponent of the factor that describes the effects of atomic motion and static displacement. 2. The elements of the tensors U and/5 should always be superscripted when the refinement is referred to a crystal system rather than to a Cartesian system. This definition follows from the definition of the elements of U and /5 as contravariant tensor components (see §2.1). The frequent use of subscripts for the ADPs, and specifically for those not referred to Cartesian systems, is inconsistent with their tensorial properties. 3. With the common Gaussian approximation, use either the quantities U ij, which have dimension (length) 2, defined in (25), or the dimensionless/3/j, defined in (22). 4. When the Gaussian approximation to the probability density function is not deemed valid, the use of the Gram-Charlier expansion of (62) is recommended, although other formalisms may sometimes be advantageous for special problems. 5. Standard uncertainties of ADPs obtained from a full-matrix refinement are valid within the system in which the refinement is made. If ADPs are transformed to any other axial system, Cartesian or not, then the uncertainties may also be calculated by transforming the original variance-covariance matrix to this new axial system and taking the square roots of its diagonal elements, i.e. the variances. The required variance-covariance matrix is usually not available for ADPs taken from the literature. Hence, although ADPs can still be transformed, their uncertainties cannot be. Calculations involving published ADPs and their (published) uncertainties should therefore be referred to the same system of coordinates as the original refinement in order to retain the significance of the published uncertainties. 6. Avoid using the term 'temperature factor', both because the phenomenon represented may not be due entirely to thermal motion and because that phrase has in the past been used in several quite distinct senses (see §1.5). 7. Avoid using the Gaussian anisotropic parameters that are now usually symbolized as B ij and are defined in (26). These quantities are directly proportional to the recommended U ij, the ratio being 87r 2. 8. Avoid using ADPs that do not represent matrix elements. In some early references and computer programs, cross terms were sometimes doubled in magnitude, being represented, for example, as hk~ 12 instead of 2hk~ 12 for programming convenience. This was possible because the matrix representing the ADP is symmetric, with only six independent terms. This practice is not found in modern crystallographic software. 9. Published values of Ueq should always be accompanied by their standard uncertainties. The ratio of the minimum to the maximum eigenvalues of the corresponding anisotropic displacement tensors should also be published, either in the primary publication itself or in the secondary (deposition) publication. Authors of crystallographic software and crystallographers who maintain their own software are encouraged to introduce the minor modifications that are required for the implementation of these Recommendations. [ Last edited by staphlee on 2009-7-13 at 09:14 ] |
» 猜你喜欢
江西科技师范大学物理化学课题组接收调剂生,12点开启,速来
已经有0人回复
【2026 考研调剂】哈尔滨工程大学 招收学硕调剂生(英语一、数学一)
已经有0人回复
无机化学论文润色/翻译怎么收费?
已经有274人回复
四川轻化工大学化学与环境工程学院 付昱教授课题组招收调剂硕士研究生
已经有11人回复
大连化物所招收有机背景的博士候选人
已经有0人回复
在MOF中,有没有羧基参加配位的情况
已经有2人回复
招2026年入学上海交通大学博士生,急!!!
已经有1人回复
理论计算合作
已经有0人回复
2楼2009-11-18 22:39:26
3楼2009-11-19 13:06:19











回复此楼