| ²é¿´: 920 | »Ø¸´: 0 | ||
cao0826гæ (³õÈëÎÄ̳)
|
[ÇóÖú]
cifÇóÖú
|
|
µ¥¶ÀcheckcifÎļþûÓÐABÀà´íÎ󣬿ÉÊÇͶÎÄÕÂcheckcifÎļþµÄʱºò³öÏÖABÀà´íÎó£¬ÓÐÈËÖªµÀÕâ¸öÓ¦¸ÃÔõô´¦ÀíÂ -------------------------------------------------------------------------------- Alert level A DIFF013_ALERT_1_A _diffrn_reflns_limit_h_min is missing Minimum h index of measured data. The following tests will not be performed REFLL_01 DIFF014_ALERT_1_A _diffrn_reflns_limit_h_max is missing Maximum h index of measured data. The following tests will not be performed REFLL_01 DIFF015_ALERT_1_A _diffrn_reflns_limit_k_min is missing Minimum k index of measured data. The following tests will not be performed REFLL_01 DIFF016_ALERT_1_A _diffrn_reflns_limit_k_max is missing Maximum k index of measured data. The following tests will not be performed REFLL_01 DIFF017_ALERT_1_A _diffrn_reflns_limit_l_min is missing Minimum l index of measured data. The following tests will not be performed REFLL_01 DIFF018_ALERT_1_A _diffrn_reflns_limit_l_max is missing Maximum l index of measured data. The following tests will not be performed REFLL_01 ABSTY01_ALERT_1_A The absorption correction should be one of the following * none * analytical * integration * numerical * gaussian * empirical * psi-scan * multi-scan * refdelf * sphere * cylinder -------------------------------------------------------------------------------- Alert level B PLAT025_ALERT_1_B Hmin..Lmax Data Incomplete or Missing .......... Please Check -------------------------------------------------------------------------------- Alert level A DIFF013_ALERT_1_A _diffrn_reflns_limit_h_min is missing Minimum h index of measured data. The following tests will not be performed REFLL_01 DIFF014_ALERT_1_A _diffrn_reflns_limit_h_max is missing Maximum h index of measured data. The following tests will not be performed REFLL_01 DIFF015_ALERT_1_A _diffrn_reflns_limit_k_min is missing Minimum k index of measured data. The following tests will not be performed REFLL_01 DIFF016_ALERT_1_A _diffrn_reflns_limit_k_max is missing Maximum k index of measured data. The following tests will not be performed REFLL_01 DIFF017_ALERT_1_A _diffrn_reflns_limit_l_min is missing Minimum l index of measured data. The following tests will not be performed REFLL_01 DIFF018_ALERT_1_A _diffrn_reflns_limit_l_max is missing Maximum l index of measured data. The following tests will not be performed REFLL_01 ABSTY01_ALERT_1_A The absorption correction should be one of the following * none * analytical * integration * numerical * gaussian * empirical * psi-scan * multi-scan * refdelf * sphere * cylinder -------------------------------------------------------------------------------- Alert level B PLAT025_ALERT_1_B Hmin..Lmax Data Incomplete or Missing .......... Please Check |
» ²ÂÄãϲ»¶
ËÄ´¨Çữ¹¤´óѧ»¯Ñ§Óë»·¾³¹¤³ÌѧԺ ¸¶êŽÌÊÚ¿ÎÌâ×éÕÐÊÕµ÷¼Á˶ʿÑо¿Éú
ÒѾÓÐ11È˻ظ´
´óÁ¬»¯ÎïËùÕÐÊÕÓлú±³¾°µÄ²©Ê¿ºòÑ¡ÈË
ÒѾÓÐ0È˻ظ´
ÎÞ»ú»¯Ñ§ÂÛÎÄÈóÉ«/·ÒëÔõôÊÕ·Ñ?
ÒѾÓÐ202È˻ظ´
ÔÚMOFÖУ¬ÓÐûÓÐôÈ»ù²Î¼ÓÅäλµÄÇé¿ö
ÒѾÓÐ2È˻ظ´
ÕÐ2026ÄêÈëѧÉϺ£½»Í¨´óѧ²©Ê¿Éú£¬¼±£¡£¡£¡
ÒѾÓÐ1È˻ظ´
ÀíÂÛ¼ÆËãºÏ×÷
ÒѾÓÐ0È˻ظ´
Çó¸ßУºÏ×÷
ÒѾÓÐ1È˻ظ´
27¼¶ÎÞ»ú»¯Ñ§É격×Ô¼ö
ÒѾÓÐ2È˻ظ´











»Ø¸´´ËÂ¥
10